SPECIFICATION CONTROL DRAWING
Product Revision
Product
Name
D-108-0033
D
Product Dimensions
L
øA
øB
max
min
min
31.0
8.75
9.75
(1.220)
(0.345)
(0.385)
øD
max
9.75
(0.385)
Cable Dimensions
øE
J±0.5
min
(J±0.02)
5.00
9.5
(0.200)
(0.375)
M±0.5
(M±0.02)
10.8
(0.425)
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Sn96 per ANSI-J-STD-006.
FLUX:
TYPE ROM1 per ANSI-J-STD-004.
3. MELTABLE RINGS: Thermally stabilized thermoplastic. Color: gray.
APPLICATION
1. This part is designed to provide an environment protected shield termination on cables, rated for 135°C minimum, meeting the
dimensional criteria listed, having nickel plated copper shields.
2. Install using Raychem-approved convection or infrared tools in accordance with Raychem assembly procedure RCPS-100-70.
3. Assemblies will meet requirements of Raychem specification RT-1404 and National Aerospace Standard NAS-1747.
2. Temperature range: -55°C to +175°C.
For best results, prepare the cable as shown:
* A trademark of Raychem Corporation.
THERMOFIT
DEVICES
Raychem Corporation
300 Constitution Drive
Menlo Park, CA 94025
USA
TITLE:
SOLDERSLEEVE* SHIELD
TERMINATOR
DOCUMENT NO.:
DCR NUMBER:
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
INCHES DIMENSIONS ARE BETWEEN BRACKETS.
Raychem reserves the right to amend this
ANGLES: N/A
TOLERANCES:
drawing at any time. Users should evaluate
0.00 N/A
the suitability of the product for their
ROUGHNESS IN
0.0 N/A
application.
MICRON
0 N/A
D-108-0033
REPLACES:
D981832
SCALE:
None
SIZE:
A
D980440
SHEET:
1 of 1
DRAWN BY:
DATE:
PROD. REV.
DOC ISSUE:
M. FORONDA
28-Oct-98
SEE TABLE
3