Description
Cable Assembly, 28AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-710-5-67GS8J7-18LTN Overview

Cable Assembly, 28AWG,

177-710-5-67GS8J7-18LTN Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7004972174
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL9.35
Other featuresSTANDARD: MIL-DTL-83513, EMI SHIELDED
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D FEMALE
ConnectorSide2MICRO-D FEMALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.081 mm2
DIN complianceNO
IEC complianceNO
insulator materialCROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE
length0.467 mm
MIL complianceYES
Number of conductors67
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.244 Ω
shieldYES
stay7X36
Wire gauge28 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
What's wrong with my 595 water control light? Kneel down with tears and beg for help
#includereg52.h #define uint unsigned int #define uchar unsigned char sbit shcp=P1^0; sbit ds=P1^1; sbit stcp=P1^2; sbit oe1=P1^6; sbit oe2=P1^ 7; uchar code table1[]={ 0xaa,0x55,0xaa,0x55, 0xaa,0x55,...
zq554747236 51mcu
MSP430 MCU and Segment LCD Application Report
...
莫妮卡 Microcontroller MCU
After writing the program to Nuvoton w78E516D, P4.3 needs to be grounded or powered on before the program can start normally
Two Nuvoton W78E516D chips, at first they can write and execute programs normally through ISP. Later, after writing programs through ISP, the programs can run normally without shutting down or resetti...
jincai2004 51mcu
Q: How do you determine the inductance value when selecting a common-mode coil?
A: According to the frequency to be suppressed, the inductance of the common mode inductor and the resonant frequency of the Y capacitor are used to determine it. In practice, the component distributi...
Jacktang Analogue and Mixed Signal
What does BMS device learning and chemical ID mean?
What does BMS device learning and chemical ID mean?...
QWE4562009 Discrete Device

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2522  855  2102  1469  2629  51  18  43  30  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号