EEWORLDEEWORLDEEWORLD

Part Number

Search

177-740-2-69CS6J1-18MNN

Description
Cable Assembly, 26AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-740-2-69CS6J1-18MNN Overview

Cable Assembly, 26AWG,

177-740-2-69CS6J1-18MNN Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7005065352
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL8.23
Other featuresSTANDARD: MIL-DTL-83513
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D FEMALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.129 mm2
DIN complianceNO
IEC complianceNO
insulator materialCROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE
length0.467 mm
MIL complianceYES
Number of conductors69
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.147 Ω
shieldNO
stay19X38
Wire gauge26 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
Circuit Design Talk 10: Grounding (1)
Circuit Design Talk 10: Grounding (1) I have always wanted to talk about grounding, but I always find it difficult to start. Grounding, the simplest definition, is also the most difficult to grasp. It...
linda_xia Analog electronics
Hello everyone, welcome to join Google Android's QQ group: 62710437
Hello everyone, welcome to join the Google Android QQ group: 62710437. Let's discuss, explore and make progress together!...
lxd1227 Embedded System
[Help] How to run three tasks on UCOS with 1k of RAM?
I use f437, 1k ram. I can run two tasks now, no problem. But when I run three tasks, it fails. I wonder if any heroes can give some guidance....
tanta Microcontroller MCU
Wince5.0 horizontal screen to vertical screen problem
The CPU used is Samsung 2450. Under Wince5.0, I changed the horizontal screen to vertical screen. According to the method under 2440, I set the registry key to HKEY_LOCAL_MACHINE\System\GDI\Rotation] ...
fengyongbo Embedded System
PCB
Can someone please tell me how to draw the terminal in PCB?...
305374869 PCB Design
msp430g2553 alarm clock source program
#include"config.h" #define SDA_DIR_OUT P1DIR|=BIT4 #define SDA_DIR_IN P1DIR&=~BIT4 #define SCL_DIR_OUT P1DIR|=BIT5 #define SDA_IN P1IN&BIT4 #define SDA1 P1OUT|=BIT4 #define SDA0 P1OUT&=~BIT4 #define S...
Jacktang Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1510  1703  1474  2687  324  31  35  30  55  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号