EEWORLDEEWORLDEEWORLD

Part Number

Search

177-740-5-67GP6J1-18PSN

Description
Cable Assembly, 26AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-740-5-67GP6J1-18PSN Overview

Cable Assembly, 26AWG,

177-740-5-67GP6J1-18PSN Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7005113848
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL9.35
Other featuresSTANDARD: MIL-DTL-83513, EMI SHIELDED
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D MALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.129 mm2
DIN complianceNO
IEC complianceNO
insulator materialCROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE
length0.466 mm
MIL complianceYES
Number of conductors67
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.147 Ω
shieldYES
stay19X38
Wire gauge26 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
Mail
Why is the password of the 163 email account of the moderator incorrect? :(...
liangjizeng Industrial Control Electronics
EEWORLD University - Detailed Explanation of Atmel Tools
Detailed explanation of Atmel tools : https://training.eeworld.com.cn/course/52To meet the challenges faced by MCU developers, such as an 80% increase in workload, time schedule requirements, more com...
dongcuipin Talking
Interior design skills and calculation methods
[b] Several common lighting methods can be divided into five types according to the spatial distribution of the luminous flux of the lamp and the installation method of the lamp: 1. Direct lighting: T...
qwqwqw2088 LED Zone
Digital Electronics designs digital control power supplies with a certain output voltage range and functions
1. Basic requirements   ( 1 ) Output voltage: range 0 ~ + 9.9V , step 0.1V , ripple no more than 10mV ;   ( 2 ) Output current: 500mA ;   ( 3 ) The output voltage value is displayed by a digital tube;...
jiujiemeiyimiao LED Zone
Indoor positioning and alarm system for personnel implemented with QT
I am a weak player. I just started to learn embedded systems this year. It is really a shame for me to show off my skills in front of an expert. I hope you can forgive me. :congratulate: This is a sma...
CC_Cambrian Integrated technical exchanges
What types of positions are companies in the hardware field recruiting for?
Could you please tell me what types of positions a company in the hardware field would recruit?...
Essen Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2476  1847  2495  2763  2184  50  38  51  56  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号