EEWORLDEEWORLDEEWORLD

Part Number

Search

CCL300DC3-TD1

Description
TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER
CategoryCircuit protection   
File Size106KB,2 Pages
ManufacturerETC
Download Datasheet View All

CCL300DC3-TD1 Overview

TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER

TYPE:
CATALOG NO.:
General Description
The CCL/TCL Series provides functional emer-
gency lighting in a variety of wattages up to 450
watts. High performance electronics and rugged
18 gauge steel construction ensure long-term life
safety reliability.
CCL/TCL Series
Housing
High Capacity Steel Emergency Lighting Units
6 and 12 Volt, 75 to 450 Watts
Wet Cell Lead Calcium Battery
Constructed of 18 gauge steel with a tan epoxy powder
coat finish.
Knockouts provided for mounting up to three lamp
heads.
Bi-color LED charge monitor/indicator and a “press-to
test” switch are located on the front of the cabinet.
Choice of wedge base, sealed beam tungsten, or halogen
lamp heads
Illumination
Illumination is accomplished with up to three
lamp heads mounted on the top of the unit. The
most popular lamp head for use with the CCL/TCL
Series is the “D” Series round sealed beam Par 36
tungsten lamp head. The “D” head is available up
to 30 watts.
Dimensions
CCL75, CCL100, CCL150, CCL225,
TCL150, TCL200
6.0”
(15.2 cm)
Electronics
120/277 VAC dual voltage input with surge-protected,
solid-state circuitry provides for a reliable charging
system.
Charging system is complete with low voltage
disconnect, AC lockout, brownout protection,
AC indicator lamp and test switch.
Includes two fused output circuits.
7.6”
(19.3 cm)
Shown: CCL150DL2
Battery
Low maintenance, free electrolyte, wet cell, lead
calcium battery
Specific gravity disk indicators show relative state
charge at a glance
Operating temperature range of battery is 65°F
(19°C)
to 85°F
(30°C)
12.0”
(30.5 cm)
16.0”
(40.6 cm)
TCL300, TCL450
6.0”
(15.2 cm)
12.0”
(30.5 cm)
Utilizes a fully automatic voltage regulated two-rate cur- Battery supplies 90 minutes of emergency power
rent limited solid-state charger -- initially provides a high
rate charge upon restoration of AC power, and provides
Code Compliance
trickle charge to maintain batteries at full capacity once UL 924 listed
float voltage is attained.
NFPA 101
Optional ACCU-TEST Self Diagnostics includes an auto-
NEC BOCA and OSHA illumination standard
matic 3 minute discharge test every 30 days. A manual
test is available from 1 to 90 minutes.
Performance
Warranty
27.0”
(12.7 cm)
Three year full electronics warranty
7.6”
(19.3 cm)
Input power requirements
120 VAC - 0.66 amps, 80 watts
277 VAC - 0.30 amps, 80 watts
One year full plus four year prorated battery warranty
Ordering Information
CCL
SERIES
CCL = 6 Volt
TCL = 12 Volt
150
DC
WATTAGE
6 Volt
75 = 75 Watts
100 = 100 Watts
150 = 150 Watts
225 = 225 Watts
12 Volt
(Includes standard voltmeter)
150 = 150 Watt
200 = 200 Watt
300 = 300 Watt
450 = 450 Watt
DL
LAMP
HEADS
6 Volt
DY = 8 Watt, Tungsten
DA = 18 Watt, Tungsten
DL = 25 Watt, Tungsten
DC = 30 Watt, Tungsten
12 Volt
DNY = 12 Watt, Tungsten
DE = 28 Watt, Tungsten
DK = 25 Watt, Tungsten
DG = 30 Watt, Tungsten
(Suggested lamp heads listed
above. Refer to the Accessories Section for
additional lamp head choices.)
2
# OF
HEADS
3 = Three
2 = Two
1 = One
TD1
FACTORY INSTALLED
OPTIONS
1
ACCESSORIES
A = Ammeter
2
ACF1 = 120 VAC Fuse
LMSHELF = Mounting Shelf 300-450W
ACF2 = 277 VAC Fuse
MXSHELF = Mounting Shelf 72-200W
ACP1 = 120 VAC Power Switch
ACP2 = 277 VAC Power Switch
AD = ACCU-TEST Self-Diagnostics
ADAL = ACCU-TEST with Alarm
ADTD = ACCU-TEST with Time Delay
3
DCP = DC Power Switch
EX = Special Input Transformer
(Specify voltage and frequency)
TD1 = 120 VAC Time Delay
3
TTD2 = 277 VAC Time Delay
3
V = Voltmeter
2
W = White Housing
Notes:
1) Some option combinations may impact UL list-
ing. consult factory for specifics.
2) Not available witj AD, ADAL, or ADTD options.
3) 15 minute delay.
C1063
R4
9/02 IH
The DA circuit output produces evenly spaced spurious waves
The circuit board is mainly composed of differential op amp + 1 dual-channel AD, 6 DA (AD9707) + differential op amp and sp6-FPGA. The DA module test method is: generate sine waves of different freque...
LUYH RF/Wirelessly
Detailed summary of STM32's nested interrupt system NVIC and RCC
The nested interrupt system NVIC and RCC of STM32 are organized in detail using the latest 3.5 library of stm32f103. I. Overview: 1. The concept of priority in STM32 (Cortex-M3) There are two concepts...
楞伽山人 stm32/stm8
Procedural issues
In a sub-function, an array Time is defined, and then a value is assigned to Time as shown in the figure. However, when the program is compiled, a warning as shown in the figure appears. I don't under...
zzbaizhi Microcontroller MCU
Ask about "Errors when using pointers as function parameters in programming"
The function that uses pointer as parameter is as follows: void write_data(uint16 addr,uint8 *s,uint8 n) { uint8 temp,addrH,addrL; temp=addr; writebyte(0xA0); addrH=temp/256; writebyte(addrH); addrL=t...
编号洞洞拐 51mcu
What majors do electronic engineers choose in the college entrance examination?
For most students, the college entrance examination is an important turning point in their lives, and choosing the right major is the key to determining their future career. If the candidate is intere...
eric_wang Talking
Dot Doctor Micro Quadcopter: How to interpret gyroscope MPU6050 data
Dr. Dot Micro Quadcopter: How to interpret the gyroscope MPU6050 data PU6050 data is a 16-bit number. It belongs to the int16 type, that is, the data range is -32768 to 32767. The positive number rang...
圆点博士 DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 859  1587  1667  1894  2497  18  32  34  39  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号