EEWORLDEEWORLDEEWORLD

Part Number

Search

MHC2355N10A3A01

Description
Absolute Magnetostrictive Sensor, 4-20mA
CategoryThe sensor   
File Size1MB,4 Pages
ManufacturerMTS Sensors
Websitehttps://www.mtssensors.com
Download Datasheet Parametric View All

MHC2355N10A3A01 Overview

Absolute Magnetostrictive Sensor, 4-20mA

MHC2355N10A3A01 Parametric

Parameter NameAttribute value
Objectid1080323739
Reach Compliance Codeunknown
Other featuresIP 67
shellSTAINLESS STEEL
Linearity(%)0.04 %
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Output range4-20mA
Output typeANALOG CURRENT
resolution100 µm
Sensor/temperature sensor typeLINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
Maximum supply voltage32 V
Minimum supply voltage10 V
Termination typePIGTAIL
Magnetostrictive Linear-Position Sensors
M-Series Mobile Equipment Sensor
Model MH
Analog Output
Temposonics
®
®
SENS
O
RS
550824 I
Product Specification
Cable Exit
Wire Exit
M-Series (Model MH)
sensor connection options
M-Series (Model MH) with analog output
(sensor cylinder application example)
Features
„
„
„
„
„
„
„
„
„
„
„
Linear, Absolute Position Sensors
Non-contact Sensor Technology
Superior Accuracy: Linearity < +/- 0.04% F.S.
Repeatability: < ± 0.005% F.S.
Compact Design for Embedded Cylinder Applications
No External Electronics
Analog Output: 0.25 - 4.75 Vdc, 4-20 mA
Sensor Stroke Length: 50 mm (1.97 in.) - 2500 mm (98.43 in.)
Power Supply: 12/24 Vdc
Shock Rating: 100 g (single hit) / IEC 68-2-27
Vibration Rating: 25 g / 10-2000 Hz / IEC 68-2-6
Benefits of magnetostrictive sensing
Temposonics linear-position sensors use the time based
magnetostrictive position sensing principle developed by MTS. Within
the sensing element, a sonic strain pulse is induced in a specially
designed magnetostrictive waveguide by the momentary interaction
of two magnetic fields. One field comes from a movable permanent
magnet that passes along the outside of the sensor. The other field
comes from an “interrogation” current pulse applied along the wave-
guide. The resulting strain pulse travels at ultrasonic speed along the
waveguide and is detected at the head of the sensing element.
The position of the magnet is determined with high precision and
speed by accurately measuring the elapsed time between the applica-
tion of the interrogation pulse and the arrival of the resulting strain
pulse with a high-speed counter. Elapsed time is used to determine
the permanent magnet position which provides an absolute position
reading that never requires recalibration or re-homing after a power
loss. Non-contact sensing eliminates wear, and guarantees the best
durability and output repeatability.
Product overview
Today’s buyers are more concerned with greater productivity,
lower overall operating costs and cost of ownership. Temposonics
M-Series Mobile Equipment sensors help lower overall costs by
increasing safety and versatility, increasing reliability and reducing
service costs. Temposonics Mobile Equipment sensors are designed
specifically for position sensing applications in rugged environments
typically encountered by construction, agriculture and other off-
highway machinery. All Temposonics Mobile Equipment sensors
utilize magnetostrictive technology.
The M-Series, Model MH sensor with analog output, is one of the
latest compact stainless-steel position sensors specifically designed
for use in welded and tie-rod style cylinders, or any space limited cyl-
inder application. The M-Series Model MH sensor is an ideal choice
for a wide range of standard hydraulic cylinders with diameters of 50
mm (1.97 in.) or larger.
The extremely rugged model MH sensor consists of the following
main components:
1. The sensor head; A robust housing with built-in electronics.
2. The pressure-proof sensor pipe; The sensor pipe houses and
protects the internal sensing element.
3. The position magnet; The magnet is mounted on the piston, during
operation it travels along the stationary sensor tube. This sensor
system is “non-contact” by design.
All specifications are subject to change. Contact MTS for specifications and engineering
drawings that are critical to your application. Drawings contained in this document are
for reference only. Go to www.mtssensors.com for the latest support documentation.
STM8SPI interrupt problem help! !
I would like to ask the following question:When debugging SPI interrupt communication, I found that the transmit empty interrupt flag is always 1 and cannot be cleared.I would like to ask how to use t...
sxjdwx stm32/stm8
How do I burn images and characters into SPI Flash and read and display them?
[img]http://www.openedv.com/upload/2014/9/10/45a864baee224fda8bf6161fbe6ecfbd_66.jpg[/img] [img]http://www.openedv.com/upload/2014/9/10/cde5b3d3f974a6547bb7293d4db3fb1d_861.jpg[/img] Hi everyone: I us...
PSIR ARM Technology
Cell phone signal jammers provide cell phone security services
Provide various mobile phone signal blockers, and provide scientific solutions according to user requirements. Provide various mobile phone signal blockers, and provide scientific solutions according ...
youngroad Industrial Control Electronics
Mass storage device abnormality, (error code 10, device cannot be started)
The mass storage device is abnormal (error code 10, the device cannot be started). What could be the reason? Waiting online urgently~~...
xiyuan98 Embedded System
Understanding MBR
[align=center][b]MBR[/b][b]Introduction[/b][/align][align=left][b]Introduction[/b][/align][align=left] [b]MBR[/b], the full name is [b]Master Boot Record[/b], that is, the [b]Master Boot Record[/b] of...
Wince.Android Embedded System
I am coming
Haha, do you miss me? Are you curious about my whereabouts? Haha, don't miss me too much. I am the lucky kid who got the M4 evaluation board. Next, I will share my experience of playing with M4....
Yehhon Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1572  2470  951  1410  193  32  50  20  29  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号