EEWORLDEEWORLDEEWORLD

Part Number

Search

C1812A511G2GAGTM

Description
Ceramic Capacitor, Multilayer, Ceramic, 200V, 2% +Tol, 2% -Tol, BP, -/+30ppm/Cel TC, 0.00051uF, 1812,
CategoryPassive components    capacitor   
File Size160KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

C1812A511G2GAGTM Overview

Ceramic Capacitor, Multilayer, Ceramic, 200V, 2% +Tol, 2% -Tol, BP, -/+30ppm/Cel TC, 0.00051uF, 1812,

C1812A511G2GAGTM Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid926640757
package instruction, 1812
Reach Compliance Codenot_compliant
ECCN codeEAR99
YTEOL6.62
capacitance0.00051 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high2.03 mm
JESD-609 codee4
length4.57 mm
multi-layerYes
negative tolerance2%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Plastic, 7 Inch
positive tolerance2%
Rated (DC) voltage (URdc)200 V
seriesC1812(BP,200V)
size code1812
Temperature characteristic codeBP
Temperature Coefficient30ppm/Cel ppm/°C
Terminal surfaceGold (Au)
width3.18 mm
CERAMIC HIGH RELIABILITY
GENERAL INFORMATION GR900 SERIES
HIGH RELIABILITY — GR900
GR900 capacitors are intended for use in any application where
the chance of failure must be reduced to the lowest possible
level. While any well-made multilayer ceramic capacitor is an
inherently reliable device, GR900 capacitors receive special
attention in all phases of manufacture including:
— Raw Materials Selection
— Special Designs
— Clean Room Production
— Individual Batch Testing
— C-SAM (when applicable)
— Singular Batch Identity is Maintained
— Destructive Physical Analysis
These parts are well worth the added investment in comparison
to the cost of a device or system failure.
Typical applications include:
Medical, Aerospace, Communication Satellites, Radar, Guidance
Systems.
SCREENING AND SAMPLE TESTS
Each batch receives the following testing/inspections:
Preliminary:
1. Destructive Physical Analysis: (DPA) - A sample is pulled from
each lot and examined per EIA-469 and KEMET’s strict internal
void and delamination criteria. Sampling plan is per MIL-PRF-123.
2. C-SAM - May be performed on batches failing to meet the
DPA criteria for removal of marginal product. Not required on
each lot.
Group A
1. Thermal Shock
— Materials used in the construction of mul-
tilayer ceramic capacitors possess various thermal coefficients of
expansion. To assure maximum uniformity, each part is temper-
ature cycled in accordance to MIL-STD-202, Method 107,
Condition A with Step 3 being 125°C. Number of cycles shall be
20 (100% of lot).
2. Voltage Conditioning
— One of the most strenuous environ-
ments for any capacitor is the high temperature/high voltage test.
All units are subject to twice-rated voltage to the units at the max-
imum rated temperature of 125°C for a minimum of 168 hours
and a maximum of 264 hours. The voltage conditioning may be
terminated at any time during 168 hours to 264 hours time inter-
val that confirmed failures meet the requirements of the PDA dur-
ing the last 48 hours of 1 unit or .4% (100% of lot).
Optional Voltage Conditioning (Accelerated Voltage
Conditioning)
— All conditions of the standard voltage condi-
tioning apply with the exception of increased voltage and
decreased test time. Refer to MIL-PRF-123 for the proper formula.
*Step 5 is performed on chips at this point (100% of lot).
3. Dielectric Withstanding Voltage
— 250% of the dc rated volt-
age at 25°C (100% of lot).
4. Insulation Resistance
— The 25°C measurement with rated
voltage applied shall be the lesser of 100 GΩ or 1000 megohm-
microfarads (100% of lot).
*5. Insulation Resistance
— The 125°C measurement with
rated voltage applied shall be the lesser of 10 GΩ or 100
megohm-microfarads (100% of lot). For chips, 125°C IR is per-
formed prior to Step 3 above.
6. Storage
at 150°C for 2 hours minimum without voltage applied
followed by a 12-hour minimum stabilization period (temperature
characteristic BX only).
7. Capacitance
— Shall be within specified tolerance at 25°C
(100% of lot). (Aging phenomenon is taken into account for BX
dielectric to obtain capacitance.)
8. Dissipation Factor
— Shall not exceed 2.5% for X7R (BX)
dielectric, 0.15% for C0G (BP) dielectric at 25°C. (100% of lot.)
9. Percent Defective Allowable (PDA)
— The overall PDA is 8%
for parts outside the MIL-PRF-123 values. The PDA is per MIL-
PRF-123 for all parts that are valid MIL-PRF-123 values. The PD
includes steps 1 through 8 above with the following exceptions.
Capacitance exclusion - capacitance values no more than 5% or
.5pF, whichever is greater for BX characteristic or 1% or .3pF,
whichever is greater for BP characteristic beyond specified toler-
ance limit, shall be removed from the lot but shall not be consid-
ered defective for determination of the PD.
Insulation Resistance at 25°C — Product which is not acceptable
for twice the military limit but is acceptable per the military limit,
is removed from the lot but shall not be considered defective for
determination of the PD.
10. Visual and Mechanical Examination
— Performed per MIL-
PRF-123 criteria.
11. Radiographic Examination (Leaded Devices Only)
Radial devices receive a one-plane X-ray.
12. Destructive Physical Analysis (DPA)
— A sample is exam-
ined on each lot per EIA-469. Sampling Plan is per MIL-PRF-123.
STANDARD PACKAGING
All products are packaged in trays except C512 capacitors which
are packaged 1 piece per bag.
DATA PACKAGE
A data package is sent with each shipment which contains:
1.
Final Destructive Physical Analysis (DPA) report.
2.
Certificate of Compliance stating that the parts meet all applic-
able requirements of the appropriate military specification to the
best failure level to which KEMET is approved.
3.
Summary of Group A Testing.
12
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Looking for an operational amplifier!
I want to find the use of an operational amplifier: Pin 5 is grounded, Pins 1 and 7 are not used, Pins 4 and 8 are connected to the power supply, and Pin 6 is the output! I want to ask if anyone has s...
305374869 Analog electronics
How to integrate *.cab package into code? ~~~
We are currently using the K3 platform and are working on a WQGA screen camera. The supplier only provides a cab package, which works after a try. My goal is: as long as the cab package works when the...
killer302vs Embedded System
High voltage inverter research and development
Use this chip to develop a high-voltage variable-frequency power unit control system...
traveller FPGA/CPLD
Upload some MSP430 information I collected myself.
MSP430 system microcontroller interface technology and system design examplesMSP430 MCU Development and ApplicationMSP430 series 16-bit ultra-low power microcontroller principle and applicationDesign ...
billjing Microcontroller MCU
CCS Beginner Questions
1. Do I need to set the relevant options in setup ccs before opening ccs? 2. I created a new project and added .c .cmd rts.lib vector.asm rebuild all. The result is error: library 'C:\\CCStudio_v3.3\\...
cl丑小鸭 DSP and ARM Processors
Does anyone have a Chinese tutorial for Microwave Office? Can you lend it to me?
I need it urgently, please help me. An electronic version is best....
bliefroad Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 820  1000  2865  485  891  17  21  58  10  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号