Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
T2039_T322_AXIAL_T323 • 8/19/2021
3
Tantalum Through-Hole Capacitors – Molded Axial
T322 & T323 MIL-PRF-49137/1 and /5 (CX01 & CX05 Style)
Table 1 – Ratings & Part Number Reference
Rated
Voltage
(V) 85°C
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
(V) 85°C
Rated
Cap
µF
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
3.3
3.9
3.9
4.7
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
82.0
100.0
120.0
µF
Case Code/
Case Size
A
A
A
B
B
B
B
B
B
C
C
C
C
A
A
A
B
B
B
B
B
B
C
C
C
C
D
D
A
A
B
A
B
B
B
B
B
B
B
C
C
C
C
D
D
D
D
E
E
E
KEMET Part
Number
(See below for
part options)
T322A685(1)002A(2)
T322A825(1)002A(2)
T322A106(1)002A(2)
T322B126(1)002A(2)
T322B156(1)002A(2)
T322B186(1)002A(2)
T322B226(1)002A(2)
T322B276(1)002A(2)
T322B336(1)002A(2)
T322C396(1)002A(2)
T322C476(1)002A(2)
T322C566(1)002A(2)
T322C686(1)002A(2)
T322A475(1)004A(2)
T322A565(1)004A(2)
T322A685(1)002A(2)
T322B825(1)004A(2)
T322B106(1)004A(2)
T322B126(1)004A(2)
T322B156(1)004A(2)
T322B186(1)004A(2)
T322B226(1)004A(2)
T322C276(1)004A(2)
T322C336(1)004A(2)
T322C396(1)004A(2)
T322C476(1)004A(2)
T322D566(1)004A(2)
T322D686(1)004A(2)
T322A335(1)006A(2)
T322A395(1)006A(2)
T322B395(1)006A(2)
T322A475(1)006A(2)
T322B475(1)006A(2)
T322B565(1)006A(2)
T322B685(1)006A(2)
T322B825(1)006A(2)
T322B106(1)006A(2)
T322B126(1)006A(2)
T322B156(1)006A(2)
T322C186(1)006A(2)
T322C226(1)006A(2)
T322C276(1)006A(2)
T322C336(1)006A(2)
T322D396(1)006A(2)
T322D476(1)006A(2)
T322D566(1)006A(2)
T322D686(1)006A(2)
T322E826(1)006A(2)
T322E107(1)006A(2)
T322E127(1)006A(2)
(see below for
part options)
DC
Leakage
µA at 25°C
Max/5 Minimum
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.8
0.9
1.1
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.7
0.9
1.1
1.2
1.5
1.8
2.2
0.5
0.5
1.0
0.5
1.0
1
1
1
1
1
1
0.9
1.1
1.3
1.5
1.9
3
2.7
3.3
3.9
4.8
5.0
µA at 25°C
Max/5 Minimum
DF
% at 25°C
120 Hz Maximum
10
10
10
10
10
10
10
10
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
4
4
6
4
6
6
6
8
8
8
8
6
6
6
8
6
8
6
6
8
8
8
% at 25°C
120 Hz Maximum
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX01D395(3)
CX05D475(3)
CX01D475(3)
CX01D565(3)
CX01D685(3)
CX01D825(3)
CX01D106(3)
CX01D126(3)
CX05D156(3)
T323B395(3)006AS
T323A475(3)006AS
T323B475(3)006AS
T323B565(3)006AS
T323B685(3)006AS
T323B825(3)006AS
T323B106(3)006AS
T323B126(3)006AS
T323B156(3)006AS
CX05D336(3)
CX05D476(3)
T323C336(3)006AS
T323D476(3)006AS
Rated Voltage
Rated Cap
Case Code/
Case Size
Military Part Number
KEMET Part Number
KEMET Part Number
DC
Leakage
DF
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
(3) To complete MIL-PRF part number, insert M for ± 20%, K for ± 10%. Designates Capacitance tolerance.
(4) To complete MIL-PRF part number, insert 01 for specification sheet /1 or 05 for specification sheet /5.
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
T2039_T322_AXIAL_T323 • 8/19/2021
4
Tantalum Through-Hole Capacitors – Molded Axial
T322 & T323 MIL-PRF-49137/1 and /5 (CX01 & CX05 Style)
Table 1 – Ratings & Part Number Reference cont.
Rated
Voltage
(V) 85°C
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
(V) 85°C
Rated
Cap
µF
150.0
180.0
220.0
270.0
330.0
2.2
2.7
2.7
3.3
3.3
3.9
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
82.0
100.0
120.0
150.0
180.0
220.0
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
µF
Case Code/
Case Size
E
E
E
F
F
A
A
B
A
B
B
B
B
B
B
B
C
C
C
C
D
D
D
D
E
E
E
E
E
E
F
F
A
A
A
B
B
B
B
B
B
C
C
C
C
D
D
D
D
E
KEMET Part
Number
(See below for
part options)
T322E157(1)006A(2)
T322E187(1)006A(2)
T322E227(1)006A(2)
T322F277(1)006A(2)
T322F337(1)006A(2)
T322A225(1)010A(2)
T322A275(1)010A(2)
T322B275(1)010A(2)
T322A335(1)010A(2)
T322B335(1)010A(2)
T322B395(1)010A(2)
T322B475(1)010A(2)
T322B565(1)010A(2)
T322B685(1)010A(2)
T322B825(1)010A(2)
T322B106(1)010A(2)
T322C126(1)010A(2)
T322C156(1)010A(2)
T322C186(1)010A(2)
T322C226(1)010A(2)
T322D276(1)010A(2)
T322D336(1)010A(2)
T322D396(1)010A(2)
T322D476(1)010A(2)
T322E566(1)010A(2)
T322E686(1)010A(2)
T322E826(1)010A(2)
T322E107(1)010A(2)
T322E127(1)010A(2)
T322E157(1)010A(2)
T322F187(1)010A(2)
T322F227(1)010A(2)
T322A155(1)015A(2)
T322A185(1)015A(2)
T322A225(1)015A(2)
T322B275(1)015A(2)
T322B335(1)015A(2)
T322B395(1)015A(2)
T322B475(1)015A(2)
T322B565(1)015A(2)
T322B685(1)015A(2)
T322C825(1)015A(2)
T322C106(1)015A(2)
T322C126(1)015A(2)
T322C156(1)015A(2)
T322D186(1)015A(2)
T322D226(1)015A(2)
T322D276(1)015A(2)
T322D336(1)015A(2)
T322E396(1)015A(2)
(see below for
part options)
DC
Leakage
µA at 25°C
Max/5 Minimum
5.0
8.6
10.0
10.0
10.0
0.5
0.5
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0.7
1.0
1.0
1.2
1.4
1.5
2.0
3
5
5
4.4
5.0
5.0
8.0
9.6
10.0
10.0
10.0
0.5
0.5
1.0
0.5
0.5
0.5
0.6
0.7
1.0
1.0
1.2
1.4
1.5
2.2
3.0
3.2
5.0
4.7
µA at 25°C
Max/5 Minimum
DF
% at 25°C
120 Hz Maximum
8
8
8
8
8
4
4
6
6
6
4
4
4
6
6
8
6
6
6
8
8
8
8
8
6
6
8
8
8
8
8
8
4
4
6
4
4
4
4
4
6
6
6
6
8
6
8
6
8
6
% at 25°C
120 Hz Maximum
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX01F275(3)
CX05F335(3)
CX01F335(3)
T323B275(3)010AS
T323A335(3)010AS
T323B335(3)010AS
CX05F106(3)
T323B106(3)010AS
CX05F226(3)
CX05F276(3)
CX05F336(3)
CX05F396(3)
CX05F476(3)
T322C226(3)010AS
T322D276(3)010AS
T323D336(3)010AS
T322D396(3)010AS
T323D476(3)010AS
CX05H225(3)
T323A225(3)015AS
CX05H685(3)
T323B685(3)015AS
CX05H156(3)
CX05H226(3)
CX05H336(3)
Military Part Number
T323C156(3)015AS
T323D226(3)015AS
T323D336(3)015AS
KEMET Part Number
Rated Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
(3) To complete MIL-PRF part number, insert M for ± 20%, K for ± 10%. Designates Capacitance tolerance.
(4) To complete MIL-PRF part number, insert 01 for specification sheet /1 or 05 for specification sheet /5.
Invitation to the "First China R&D Management Summit" November 22-24, 2007 Beijing Product development is the industrial battlefield of the 21st century, just as manufacturing was the industrial battl...
Enter SILICON LABS official website:
https://cn.silabs.com/development-tools/mcu/32-bit/efm32pg22-development-kit Then select "Get Started"on the web pageand download and installSimplicity Studio vers...
The domestic chip GD is compatible with STM32, and the BUG has been fixed. It supports the same firmware library and is cheaper than STM32. Has anyone used it?...
[backcolor=rgb(238, 238, 238)][size=12px] Need to evaluate MCU for a project? Need a core board for a small project but don't see a suitable one? The development boards on the market have complicated ...
The C6678.cmd file is grayed out for some reason. I didn't notice it at first, but when I compiled the project, I found that all memory allocated in DDR failed. Is it possible that my cmd file is not ...
I want to buy a spectrum analyzer, mainly for testing RF transceiver units at 430MHz, 860Mhz, and 2.4GHz. Can anyone recommend a brand or model that you have used and found good? If I adopt your sugge...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
Ever since the Tesla fire incident, electric cars, already known for their poor reputation, have been subjected to even more scathing criticism. Despite this, many people are still willing to buy t...[Details]
On August 21, WeRide officially launched WePilot AiDrive, a one-stage end-to-end assisted driving solution developed in cooperation with Bosch. This comes only half a year after the two parties' "t...[Details]
Have you ever heard stories about "crazy appliances"? Think of microwaves that turn on automatically or ovens that preheat without any human input? With radios and electromagnetic interfaces ubiqui...[Details]
Electric vehicles are now widespread, but they've brought with them a host of problems, the most prominent of which is charging. Small electric vehicles (EVs) are a new form of transportation in a ...[Details]
There are basically three causes of spontaneous combustion of electric vehicles: The first is that the battery components are punctured or suffer fatal damage due to a collision accident, and part ...[Details]
Electric vehicles are powered by electricity, and charging is a device that supplements the vehicle's energy source. It is common to need to recharge the vehicle when driving. But can you charge th...[Details]
Magna's integrated in-cabin perception system fuses vision and millimeter-wave radar data to detect the presence of passengers, identify stranded children, monitor driver fatigue and vital signs, a...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]
In the field of intelligent driving, regulations are becoming increasingly stringent, and the technical threshold continues to rise. Especially after the traffic accident in March 2025, the Ministr...[Details]
A tubular motor is an electric motor that is typically used to control the movement of machines and equipment. Tubular motors are generally divided into two categories: linear tubular motors and ro...[Details]
In daily life, when we purchase a transformer, we are faced with the installation and wiring procedures. Generally speaking, large transformers such as power transformers are equipped with speciali...[Details]
A pure sine wave inverter has a good output waveform with very low distortion, and its output waveform is essentially the same as the AC waveform of the mains power grid. In fact, the AC power prov...[Details]
A scale, a large, ground-mounted scale, is typically used to measure the tonnage of truck cargo. It's the primary weighing device used in factories, mines, and businesses for bulk cargo measurement...[Details]