EEWORLDEEWORLDEEWORLD

Part Number

Search

DS1601-9RD9

Description
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, HEAT SINK, METAL, CASE S02, MODULE
CategoryPower/power management    The power supply circuit   
File Size439KB,33 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

DS1601-9RD9 Overview

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, HEAT SINK, METAL, CASE S02, MODULE

DS1601-9RD9 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE S02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage220 V
Minimum input voltage44 V
Nominal input voltage110 V
JESD-30 codeR-MXMA-X
Maximum load regulation0.167%
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage26.4 V
Minimum output voltage9.6 V
Nominal output voltage24 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Fine-tuning/adjustable outputYES
Base Number Matches1
S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
Features
Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz
1or 2 isolated outputs up to 48 VDC
Class I equipment
RoHS lead solder exemption compliant
Extremely-wide input voltage range
Input over- and undervoltage lockout
Efficient input filter and built-in surge and transient
suppression circuitry
Outputs: SELV, no-load, and short-circuit proof
No derating over entire operating temperature range
111
4.4"
3U
60
2.4"
12 TE
168
6.6"
PCBs coated with protective lacquer
Very high reliability
Safety according to IEC/EN 60950
Description
The S Series AC-DC and DC-DC converters represents a broad
and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LS models can be powered by
DC or AC with a wide-input frequency range (without PFC).
The converter inputs are protected against surges and
transients. An input over- and undervoltage lockout circuitry
disables the outputs if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-on.
All outputs are open- and short-circuit proof and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to pin 18
(i). If the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.
Full input-to-output, input-to-case, output-to-case and output-to-
output isolation is provided. The converters are designed and
built according to the international safety standards IEC/EN
60950 and EN50155. They have been approved by the safety
agencies TÜV and UL (for USA and Canada).
The case design allows operation at nominal load up to 71 °C in a
free-air ambient temperature. If forced cooling is provided, the
ambient temperature may exceed 71 °C, but the case temperature
must remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which disables
the outputs if the case temperature
Tc
exceeds the limit. The
outputs are automatically re-enabled when the temperature drops
below the limit.
Various options are available to adapt the converters to individual
applications.
The converters may either be plugged into a 19" rack system
according to IEC 60297-3, or be chassis mounted. They are ideally
suited for Railway applications.
Important:
For applications requiring compliance with IEC/EN
61000-3-2 (harmonic distortion), please use our LS4000 and LS5000
Series with incorporated power factor correction (PFC).
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ....................................15
Immunity to Environmental Conditions ..................................17
Mechanical Data ....................................................................18
Safety and Installation Instructions ........................................19
Description of Options ............................................................23
Accessories ............................................................................32
EC-Declaration of Conformity ................................................33
Description ................................................................................1
Model Selection ........................................................................2
Part Number Description and Product Marking ........................3
Functional Description ..............................................................4
Electrical Input Data ..................................................................5
Electrical Output Data ..............................................................8
Auxiliary Functions ..................................................................12
APR 26, 2006 revised to SEP 25, 2006
Page 1 of 33
www.power-one.com
arm linux driver development
Required abilities: 1. Basic principles and basic operations of Linux 2. C language is the basis. (Pointers and structures are the key points)Learning method: Read the code -- Write a driver Develop g...
多瑙河夏之夜 ARM Technology
Can bus communicates with Ethernet, does anyone have any information? Share it,
Find the solution for CAN bus and Ethernet communication......
zjd0608 Microcontroller MCU
[TI mmWave Radar Evaluation] 2+AWR1443 EVM board power-on and initial test
When using the AWR1443 EVM board, the easiest thing to do is to first perform power-on verification on the onboard software. This can be done by simply using the software mmWave_Demo_Visualizer, which...
dingzy_2002 TI Technology Forum
Looking for Chinese information on MAX3232
Looking for Chinese information on MAX3232...
starli521 Test/Measurement
Throwing Away the Current Transformer - Part 3: How to Use Shunt Current Sensors in Multiphase Metering Systems
[align=left][color=#000]Shunts are often used as current sensors in metering systems because of the many advantages they offer. [/color][/align][align=left][color=#000]However, as discussed in the pre...
maylove Analogue and Mixed Signal
How to test LED chips, fluorescent glue, and fluorescent powder
Faced with the chaos of the LED market, the various and mixed auxiliary material markets have indeed confused many new generation packaging engineers. The following are several quick and simple method...
探路者 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 808  705  778  170  1396  17  15  16  4  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号