Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
MΩ
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Table 1
Operation Mode
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MHz
Please specify the frequency
in xx.xxxxMHz.
e.g. 14.3181MHz
Load Capacitance (pF)
Please specify CL
(Minimum 10pF) in pF or
S for series
Custom ESR if other
than standard
R□
□: Specify
a value in
Ω
(e.g.: R40)
MHz -
-
-
-
-
-
-
Packaging
T: Tape & Reel
Quality Factor***
Minimum
QXXXk
Value
Value Added
I
Insulator Tab
V
Vinyl Sleeve
Trimmed leads
QXX
See Table 2
MJ
Metal jacket
Operation Mode
Fund. AT > 24MHz
F
Fund. BT>24MHz
FB
3
rd
OT>66MHz
O
Freq. Stability
Options for AT-
Cut only*
U**: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 50 ppm
Operating Temp.
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
Freq. Tolerance
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
NOTE:
*:Frequency
Stability ±100
ppm maxat -10 to +60C only
for BT cut.
**:
-10 to +60C only.
***:
Quality factor must be
accompanied by a k value
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriate code numbers for
other trimmed lengths not listed.
(e.g. Q14 for 0.14 inch (3.55 mm))
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
High efficiency and low standby power consumption are two major challenges in today's switching power supply design. Resonant topology or LLC topology is becoming increasingly popular because it ca...[Details]
The rapid development of the Internet has realized high-speed information transmission and resource sharing, greatly facilitating people's lives. Embedded systems are widely used in various electr...[Details]
Sailing is gaining more and more attention. How to use modern technology to assist training and improve competition results is particularly important. Considering the real-time data collection in t...[Details]
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
introduction
Solar cells and LED lighting are typical applications of new energy and energy-saving and efficient technologies. Solar LED lighting uses solar cells to convert solar energy...[Details]
With the development and widespread application of computer technology, especially in the field of industrial control, computer communication is particularly important. Although serial communication g...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
MediaTek (2454) announced the acquisition of F-MStar (3697) and attracted the attention of IC design industry. This morning, Gartner Semiconductor Industry Research Director Hong Cenwei analyzed ...[Details]
General LED lighting has a current limiting resistor in the driving circuit, and the power consumed by the resistor has nothing to do with the LED light emission. In order to improve efficiency, a...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Abstract: With the development and construction of BeiDou II system, China will shift from the situation dominated by GPS to the situation dominated by BeiDou II global navigation system independen...[Details]
LED guardrail lights use fluorescent tubes or LEDs as light sources and continuous guardrails as carriers to form an approximately linear guardrail light strip. This article mainly introduces...[Details]