Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
M
Ω
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
Table 1
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
Operation Mode
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MH z
Please specify the frequency
in x x .x x x x M Hz.
e .g . 14.3181MHz
MHz -
-
-
-
-
-
-
P a c k a g in g
Blank: Bulk (std.)
T: Tape & Reel
(For MJ option only)
Q u a lit y F a c t o r * * *
Minimum
QXXXk
Value
L o a d Capacit anc e (pF)
Please specify CL
(Minimum 10 pF) in pF or
S fo r series
Custo m E SR if other
than st a n d a r d
R□
□: Specify
a value in
Ω
(e .g .: R40)
Operating Temp.
A: -10°C ~ + 60° C
B: -20°C ~ + 70° C
C: -30°C ~ + 70° C
N: -30°C ~ + 85° C
D: -40°C ~ + 85° C
Valu e Added
I
V
QXX
MJ
Operation Mode
Fund. AT > 24MHz
F
FB
O
Freq. Tolerance
1: ± 10 pp m
7: ± 15 pp m
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq . St abilit y
Option s fo r A T -
Cut only *
U * * : ± 1 0 p pm
G: ± 15 ppm
X: ± 20 ppm
W : ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 5 0 p pm
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriat e code numbers for
other trimmed lengths not liste d.
(e.g. Q14 for 0.14 inch (3.55 mm))
Fund. BT>24MHz
3rd OT>66MHz
Insulator Tab
Vinyl Sleeve
T rimmed lea ds
See Ta ble 2
Metal jacket
NOTE:
*:Fr equency Stability ± 100
ppm max at -10 to +60C only
for BT cut.
** : -10 to +60C only.
*** : Quality factor must be
ac companied by a k value
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Tape and reel packaging applies only to MJ (metal jacket) option
E
1.75±0.10
E2
22.25 MIN.
F
11.5±0.10
P2
2.00±0.10
ØD0
1.50±0.10
P0
4.00±0.10
W
24.00±0.30
Dimensions: mm
ATTENTION:
Abracon products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon is required. Please contact Abracon for more information.
The rapid development of the Internet has realized high-speed information transmission and resource sharing, greatly facilitating people's lives. Embedded systems are widely used in various electr...[Details]
Today's computer peripherals are pursuing high speed and high versatility. In order to meet user needs, seven companies led by Intel launched the USB (Universal Serial Bus) bus protocol in 1994, wh...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
introduction
Solar cells and LED lighting are typical applications of new energy and energy-saving and efficient technologies. Solar LED lighting uses solar cells to convert solar energy...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
The solidification and modularization of intelligent video analysis algorithms are the current trends in the application of intelligent video analysis technology. It perfectly combines intelligent ...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]
One in five car failures are caused by batteries, a problem that will become more serious in the coming years as electric-by-wire, start/stop engine management and hybrid (electric/gas) vehicles be...[Details]
DCDC means DC to DC (conversion of different DC power values). Anything that meets this definition can be called a DCDC converter. Specifically, it means converting the input DC into AC through a s...[Details]
This paper describes the design method of electronic multifunctional watt-hour meter, the key technology of hardware design and the software design process. Taking NEC's μPD78F0338 microcontroller ...[Details]