Standard Frequencies – see Page 5 for developed frequencies.
* Check with factory for availability of frequencies not listed.
pplications
utomotive Electronics
Mobile Multimedia/Infotainment
Car Navigation Systems
Internet of Things [IoT, IIot]
Microcontrollers and FPG s
Wireless Communication
Ethernet/GbE/SyncE
Medical Electronics
Commercial Military & erospace
Description
CTS Model S 5 2 incorporates a low cost, high Q, small size quartz resonator specifically developed to operate
over extended temperature ranges for use in automotive electronics.
Ordering Information
Model
S 5 2
Frequency Code
[MHz]
X X X or X X X X
Mode of
Oscillation
F
Tolerance
@ +25°C
Temperature
Stability
5
Temperature
Range
G
Load
Capacitance
Packaging
T
Code
Frequency
Product Frequency Code
1
Code
1
X
2
5
Tolerance
±10ppm
±15ppm
±20ppm
± 0ppm
±50ppm
Code
I
G
H
N
P
M
Stability
±15ppm
±20ppm
± 0ppm
Code
5
6
7
Temp. Range
2
-40°C to +85°C
-40°C to +105°C
4
-40°C to +125°C
-40°C to +150°C
5
5
-55°C to +105°C
-55°C to +125°C
5
Packing
Code
1k pcs./reel
T
Code
F
T
Mode
Fundamental
rd Overtone
Code
X
2
Stability
±50ppm
±100ppm
±150ppm
Code Capacitance Code Capacitance
7pF
16pF
V
C
8pF
18pF
K
D
9pF
20pF
J
E
10pF
24pF
F
12pF
0pF
L
G
1 pF
Series
B
S
Notes:
1]
2]
]
4]
5]
Refer to document 016-1454-0, Frequency Code Tables. -digits for frequencies <100MHz, 4-digits for frequencies 100MHz or greater.
vailable with all stability codes.
vailable with stability codes , 5, 6 and 7.
vailable with stability codes 5, 6 and 7.
Stability codes 6 and 7. Contact factory for code 5 availability.
Not all performance combinations and frequencies may be available.
Contact your local CTS Representative or CTS Customer Service for availability.
This product is specified for use only in standard commercial applications. Supplier disclaims all express and implied warranties and liability in connection with any use of this
product in any non-commercial applications or in any application that may expose the product to conditions that are outside of the tolerances provided in its specification.
[i=s]This post was last edited by yichun417 on 2014-10-28 10:37[/i] [align=left][color=#0000ff][b]In order to meet the requirements of my country's high-speed railway construction, slab ballastless tr...
When I wrote this study note, it was not long after the last note. During this period, some netizens asked why I didn't update the article. The main reason was that I was too busy at work and didn't h...
When using assign in Verilog, the following error occurs: assign lholdA = state[1]; assign ads = state[0]; error:***Illegal LHS of continuous assign . What's going on?...
Some logical operators have two s, and some have one . The same is true for logical OR ||. Can an expert tell me if one or two give the same result?...