Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and
not Moisture Sensitive - MSL = N/A: Not Applicable
FEATURES:
• Suitable for RoHS compliant reflow
• Low height reduced to 3.3mm
• Available suitable for thin equipment
• Tight stability & extended temperature
Reduced height
to 3.3mm
Pb
RoHS
Compliant
11.4 x 4.7 x 3.3 mm
APPLICATIONS:
• Computers, Modems, Microprocessors
• Wireless Applications
STANDARD SPECIFICATIONS:
PARAMETERS
Parameters
Minimum
3.579545
Typical
-----
-----
-----
Maximum
24.00
50.00
70.00
Units
Notes
Fundamental AT
(Standard)
Fundamental AT
or
BT
(See options)
3
rd
Overtone
(Standard)
)
Frequency
Range
24.01
24.01
MHz
Operation
Mode
Operating Temperature
Storage
Temperature
Frequency
Tolerance @+25°C
Frequency
Stability
over the Operating
Temperature (
ref. to
+25°C)
Equivalent series resistance
(R1)
Shunt capacitance
(C0)
Load capacitance
(CL)
Drive Level
Aging
Insulation Resistance
Drive level dependency
(DLD)
Fundamental
or 3
rd
Overtone
0
-----
+70
-55
-----
+125
-50
-----
+50
-50
-----
-----
-----
-5
-----
See table
1
below
-----
18
100
-----
+50
7
-----
1000
+5
ºC
ºC
ppm
ppm
Ω
pF
pF
µW
ppm
See
options
See options
See
options
(For BT
cut,
±100ppm
max.at
-10° C
to
+60° C
only)
Standard
(See
options if
other than
STD)
500
-----
-----
MΩ
Minimum 7 points tested: from
1µW
to
500µW.
Change in frequency
(Maximum -
Minimum) over
DLD
range < ±10ppm
Change in
ESR
(Maximum
-
Minimum) over
DLD
range <
25%
of Max
ESR
value.
Maximum
ESR
over
DLD
range < Max
ESR value.
ESR (Ω)
180
120
100
80
60
50
40
100
80
@25°C±3°C
First year
@ 100Vdc ± 15V
TABLE 1: ESR
FREQUENCY (MHz)
3.579545
- 4.999 (Fund.)
5.000 - 5.999 (Fund.)
6.000 - 7.999 (Fund.)
8.000 - 8.999 (Fund.)
9.000 - 9.999 (Fund.)
10.000 - 15.999 (Fund.)
16.000 - 50.000 (Fund.)
24.01 -
31.999
(3rd O/T)
32.000
- 70.00 (3rd O/T)
ABRACON IS
ISO
ISO9001:2008
9001 / QS 9000
CERTIFIED
Revised: 03.31.11
30332
Esperanza, Rancho Santa
Margarita,
California 92688
tel
949-546-8000
|
fax
949-546-8001
|
www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC/ 49US (AT49) LOW PROFILE SURFACE
MOUNT MICROPROCESSOR CRYSTAL
ABLS2
Pb
RoHS
Compliant
Options and Part Identification
(left blank if standard)
Reduced height
to 3.3mm
11.4 x 4.7 x 3.3 mm
| | | | | | | | | | | | | | |
ABLS2 -
Frequency in MHz
Please specify the frequency
in MHz. e.g. 14.31818MHz
MHz -
-
-
-
-
Packaging
Blank: Bulk
T: Tape&Reel
Oscillation Mode
F: Fund. AT>24MHz
FB: Fund. BT>24MHz
Load Capacitance (pF)
Please specify CL
(Minimum 10pF) in pF or
S for series
Custom ESR if other
than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
Operating Temp.
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J*: -40°C ~ +105°C
K*: -40°C ~ +125°C
L*: -55°C ~ +125°C
Freq. Tolerance
H5: ± 5 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
U**: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
R: ± 150 ppm
NOTE: Fundamental BT frequency stability ± 100ppm max.
at -10° C to +60° C only.
* Frequency stability ±50ppm, ±100ppm, ±150ppm only.
Contact ABRACON for tighter frequency stability.
** -10 to +60C only.
ABRACON IS
ISO
ISO9001:2008
9001 / QS 9000
CERTIFIED
Revised: 03.31.11
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC/ 49US (AT49) LOW PROFILE SURFACE
MOUNT MICROPROCESSOR CRYSTAL
ABLS2
Pb
RoHS
Compliant
OUTLINE DRAWING:
Reduced height
to 3.3mm
11.4 x 4.7 x 3.3 mm
| | | | | | | | | | | | | | |
TAPE & REEL:
T = tape and reel (1000pcs/reel)
Reflow Profile
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component
failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization
from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO
ISO9001:2008
9001 / QS 9000
CERTIFIED
Revised: 03.31.11
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
King Wen of Wei asked the famous doctor Bian Que, "You have three brothers, all of whom are skilled in medicine. Which one is the best?Bian Que replied: "The eldest brother is the best, the middle bro...
After rtw is compiled, a .lo model is generated. How do you load the model .lo? When using loadModule to load, it always reports undefined symbol types... There are references that point out that the ...
1. How can I make the input panel immovable in CE5.0 application? 2. How can I show or hide the input panel and move the application window so that it is not blocked? 3. How can I add an input switch ...
This is a basic exercise for the MSP430FR5969 LaunchPad. It is programmed using the DriverLib library in CCS6. The board we designed needs to be powered off in many applications. For example, the mach...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
Due to the significant increase in electronic devices in automotive and industrial applications, the automotive and industrial markets continue to play an important role in China's electronics in...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
0 Introduction
There are many types of sensors, and the working principles, measurement targets and measurement environments of different types of sensors vary greatly. The corresponding detection s...[Details]
The demand for improved healthcare environments is endless, so medical imaging equipment with higher resolution is needed to better observe the human body. High resolution brings problems with sign...[Details]
Battery clamps, commonly known as battery connectors, come in two sizes depending on the thickness of the battery terminals. One is the battery clamp used on thick terminals, with a positive termin...[Details]
Electrostatic coupling and interference occur when a charged object is close to the input of the circuit being measured. At low impedance, the effects of interference are not noticeable because th...[Details]
When developing electronic products with processors, how to improve anti-interference ability and electromagnetic compatibility?
1. The following systems should pay special attention to anti-...[Details]
LonWorks fieldbus technology is widely used, for example, in intelligent buildings, industrial control, environmental protection, etc. Echelon's LonWorks system has been used in the products of tho...[Details]
The biggest advantage of Profibus is that it is guaranteed by the stable international standard EN50170 and has been proven to be universal in practical applications. It has been widely used in man...[Details]