124H12-E2P-02-HB

Description
Non-Linear Resistor
CategoryPassive components    The resistor   
File Size65KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

124H12-E2P-02-HB Overview

Non-Linear Resistor

124H12-E2P-02-HB Parametric

Parameter NameAttribute value
Objectid402276913
Reach Compliance Codeunknown
ECCN codeEAR99
Bussmann
®
SHORTSTOP
®
Auto, Manual & Modified Reset Circuit Protectors
Series 120
SPECIFICATIONS
Single Pole Thermal Type Breakers
Ratings:
8A to 50A; 12 VDC; 24 VDC.
Operating Temperature:
–10°F (–23°C) to 150°F (65°C).
Storage Temperature:
–20°F (–29°C) to 200°F (93°C).
Applications:
Battery chargers, trucks, buses, RV’s, trolling motors, etc.
Approvals:
Complies with SAE Standard J553.
TEMPERATURE DERATING CURVES
200%
% 0F RATED CURRENT
% 0F RATED CURRENT
150%
100%
50%
0%
-50º
Two 10-32 studs:
.66" (AUX); .56" (BAT)
.69"
(17.5)
Two 10-32 studs:
.56" (AUX & BAT)
.99"
(25.2)
.66"
(16.8)
TIME VS. PERCENT OF RATED CURRENT
600%
500%
400%
300%
200%
100%
0
5
10 15
20 30 40 100 200 500
TIME IN SECONDS
Terminal Options
.69"
(17.5)
.66"
(16.8)
.69"
(17.5)
.56"
(14.2)
A
B
.56"
(14.2)
50º 77º 100º 150º
200º
TEMPERATURE IN DEGREES F.
250º
C
D
.41"
(10.3)
Cover & Bracket Options
METAL COVER
1.24"
(31.5)
.79"
(20.1)
1.56"
(39.6)
.38" (9.6)
1.24"
(31.5)
.79"
(20.1)
PLASTIC COVER
1.27"
(32.3)
.83" 1.56"
(21.1) (39.6)
.62"
(15.7)
O Bracket
1.56"
(39.6)
.83"
1.27" (21.1)
(32.3)
A Bracket
.37" (9.4)
.37" (9.4)
Two 10-32 studs:
.66" (AUX & BAT)
.84"
(21.4)
.41"
(10.3)
Two .25" Q.C.
(AUX & BAT)
.69"
(17.5)
E
.56"
(14.2)
.41"
(10.3)
H
.56"
(14.2)
One .25" Q.C. (AUX);
One 10-32 stud (BAT)
.99"
(25.2)
.30"
(7.7)
Double .25" Q.C. (AUX);
One 10-32 stud (BAT)
.84"
(21.4)
.64"
(16.3)
O Bracket
.69"
(17.5)
A Bracket
.79"
1.24"
(31.5) (20.1)
1.27"
(32.2)
B Bracket
.12" (3.0)
dia. boss
1.27"
(32.2)
C Bracket
J
.41"
(10.3)
K
.83"
(21.1)
.54"
(13.7)
1.56"
(39.6)
.79"
(20.1)
1.24"
(31.5)
.69"
(17.5)
B Bracket
Double .25" Q.C. (AUX);
Single .25" Q.C. (BAT)
.69"
(17.5)
Two .25" Q.C. (AUX & BAT)
Perpendicular
Orientation
Reset button
.06"
(1.5)
.62"
(15.7)
1.27"
(32.3)
.83"
(21.1)
.38" (9.6)
1.56"
(39.6)
L
.37" (9.4)
.69"
(17.5)
C Bracket
Two 10-32 studs
(AUX & BAT)
.62" (15.7)
Ref. (Typ)
w/base attached
E Bracket
Series 123
O Bracket w/reset
PART NUMBERING SYSTEM
Series
Terminal
Rating
Bracket
Mtg. Holes
Cover*
Options
Hardware
1 2
ttt
t
tt
t
O – No bracket
A – Bracket
B – Bracket
C – Bracket
E – Bracket
(plastic only)
t
0 – No bracket
1 – .140 dia.
2 – .196 dia.
3 – .237 dia.
(metal only)
4 – .265 dia.
(plastic only)
5 – .228 dia.
(plastic only)
6 – .221 dia.
(metal only)
t
tt
tt
M – Metal
P – Plastic
01 – Waterproof
(metal
covers only)
02 – Splashproof
(optional on
metal covers -
add 02 suffix;
std. on plastic
covers - omit
02 suffix.)
WA – Whiz-lock nut
assembled
WB – Whiz-lock
nut bulk un-
assembled
HA – Nut & lock
washer
assembled
HB – Nut & lock
washer bulk
unassembled
KA – Keps lock nut
assembled
KB – Keps lock
nut bulk
unassembled
121 – Auto Reset
08 – 8 amps
A – Two 10-32 studs;
12 VDC
10 – 10 amps
.66 (Aux), .56 (Bat)
122 – Modified
12 – 12 amps
B – Two 10-32 studs;
12 VDC
15 – 15 amps
.56 (Aux & Bat)
123 – Manual
20 – 20 amps
C – Two 10-32 studs;
24 VDC
25 – 25 amps
.66 (Aux & Bat)
115 VAC
30 – 30 amps
***D – Two .250 QC;
124 – Auto
35 – 35 amps
(Aux & Bat)
24 VDC
***E – One .250 QC (Aux); 40 – 40 amps
125 – Modified
One 10-32 stud (Bat) 50 – 50 amps
24 VDC
** H – One 10-32 stud
.56 (Bat), Double
.250 QC (Aux)
***J – Single .250 QC (Bat)
Double .250 QC (Aux)
***K – Two .250 QC (Aux & Bat)
L – Two 10-32 studs; .37 (Aux & Bat)
* Series 123 available in plastic cover only. Series
122 & 125 available in metal cover only.
** 40A maximum
*** 30A maximum
12-16-98
SB98107 Rev. A
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies
of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide
technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design
or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or
update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the
user in all possible applications.
Form No. 120 ShortStop
Page 1 of 1
BIF Document: 2067
【Technical White Paper】Application and parameter design of bootstrap circuit in HVIC
Bootstrap Network Analysis: Focusing on the Integrated Bootstrap Functionality...
安_然 Analog electronics
Recruiting Wince developers, applications, BSP
If you have a dream, you have hope. Location: Shenzhen. Excellent treatment. Strong company. If you are interested, please send an email to pz_forever@126.com...
ckuangling Embedded System
[TI star product limited time purchase] + AWR6843 purchase experience and unboxing
[i=s]This post was last edited by wangran_95 on 2020-12-24 11:11[/i]First of all, I am very happy to participate in this event, thanks to the discount coupon from eeworld. The development board that o...
wangran_95 TI Technology Forum
EEWORLD University ---- VLSI Testing
VLSI Testing : https://training.eeworld.com.cn/course/6040This course is offered by Prof. James Chien-Mo Li, Lab of Dependable Systems, National Taiwan University. Lecture notes available on course we...
桂花蒸 Embedded System
【STEVAL-MKI109V3+LSM6DSOX】Build a test environment from scratch
When I posted before, I found that the pictures I copied and pasted were not in the document. I checked today and found that they were not chosen to be used. I will update the post accordingly. The co...
ROychen ST MEMS Sensor Creative Design Competition
Seven commonly used and effective LED light source spectroscopic and color separation detection technologies
[hide]   1. Luminous flux binning: Luminous flux value is an indicator that LED users are very concerned about. LED application customers must know the range of the LED luminous flux they use, so as t...
探路者 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1827  982  1739  515  2105  37  20  36  11  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号