EEWORLDEEWORLDEEWORLD

Part Number

Search

M5242-01000N-03KPS

Description
Pressure Sensor
CategoryThe sensor   
File Size299KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

M5242-01000N-03KPS Overview

Pressure Sensor

M5242-01000N-03KPS Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145014272424
Reach Compliance Codeunknown
YTEOL7.25
Maximum accuracy(%)0.25%
Other featuresIP67, REVERSE POLARITY PROTECTION, SHORT CIRCUIT PROTECTION
shellSTAINLESS STEEL
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range1-5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port type7/16-20 UNF FEMALE
Maximum pressure range3000 Psi
Minimum pressure range
Pressure sensing modeSEALED
Response time2000 µs
Sensor/temperature sensor typePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage30 V
Minimum supply voltage8 V
Termination typeCABLE
M5200
Industrial Pressure Transducer
SPECIFICATIONS
Wide Temperature Range
Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless-Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Compound
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.25% Accuracy
±1.0% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The M5200
pressure transducers from the Microfused line of MEAS,
with their modular design, offer maximum flexibility for different
configurations. This latest series sets a new price performance
standard for demanding commercial and heavy industrial applications.
This series is suitable for measurement of liquid or gas pressure, even
for difficult media such as contaminated water, steam, and mildly
corrosive fluids.
The wetted material is made of either 17-4 PH or 316L stainless steel
and the transducer’s durability is excellent with no welds or organics
exposed to the pressure media. The M5200 is weatherproof and
exceeds the latest heavy industrial CE requirements including surge
protection. The circuit is protected from reverse wiring at input and
short circuit at output.
This product is geared to the OEM customer for low to mid volumes.
MEAS stands ready to provide a custom design of the M5200 where
the volume and application warrants. Additional configurations not
listed are either available or possible. Please inquire for further
information.
APPLICATIONS
Industrial Process Control and Monitoring
Advanced HVAC Systems
Refrigeration Systems
Automotive Test Stands
Off-Road Vehicles
Pumps and Compressors
Hydraulic/Pneumatic Systems
Agriculture Equipment
Energy Generation and Management
SENSOR SOLUTIONS
///M5200
08/2020
Page 1
High-quality code resources recommendation (VIII) --- Refactoring - Improving the design of existing code
[align=center][color=rgb(0, 0, 0)][backcolor=rgb(237, 235, 235)][font=微软雅黑][size=5][b]Refactoring - Improving the Design of Existing Code[/b][/size][/font][/backcolor][/color][/align] [size=4][color=#...
tiankai001 Download Centre
【Design Tools】Xilinx DCM Usage
Xilinx DCM UsageAt present, it is generally recommended to use synchronous timing circuits for large-scale designs. Synchronous timing circuits are based on clock trigger edge design and have higher r...
sdjntl FPGA/CPLD
Battery discharge capacity tester/battery analyzer (schematic diagram + source code)
[color=rgb(51, 51, 51)][backcolor=rgb(247, 247, 247)][font=微软雅黑, Tahoma,]Batteries are the energy source of electric vehicles, which are directly related to the performance of electric vehicles. They ...
cardin6 Creative Market
How to solve the problem that the touch screen needs to be calibrated every time it is turned on
At present, the touch screen needs to be calibrated every time it is turned on. It should be calibrated when the system is burned for the first time, and it is not necessary in the future. How can I s...
panama Embedded System
C2000 key interrupt jitter
I am a novice who just started to learn c2000 launchpad. I set up the key interrupt program of S3-GPIO12. However, when I started running, I found that the interrupt would be entered even if no key wa...
nemo1991 Microcontroller MCU
Please tell me the function of the pull-up resistor of this transistor
The transistor in the figure is used as a switch to drive the buzzer, but the function of R41 in the figure is to pull up and provide a certain level to the transistor. Here is a question. VCC will al...
zhandizhandi Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2275  1933  2140  1247  1197  46  39  44  26  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号