Reduced footprint from ABLS (standard HC/49US package) by 50%
• Low profile: 2.0mm max. height
• Suitable for RoHS compliant reflow
• Tight stability & extended temperature options
• High reliability & Cost effective
• Resistance welded metal package
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.0mm
Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and not Moisture Sensitive - MSL = N/A: Not Applicable
APPLICATIONS:
•
Wireless Applications
• Home electronics
• Computers, modems, and communications
• Microprocessors
STANDARD SPECIFICATIONS:
Parameters
Freq
u
ency Range*
Standard Frequencies
Operation Mode
Operating Temperature
Storage Temperat
u
re
Frequency
Tolerance @+25°C
Frequency
Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent
series resistance (R1)
@+25°C
Sh
u
nt capacitance (C0)
Loa
d
capacitance (CL)
Drive Level
Aging
Ins
u
lation Resistance
Drive level
dependency
(DLD)
-5
18
50
100
+5
Minimum
Typical
Maximum
Units
M
H
z
MHz
Notes
12.0
40.0
12.0, 12.288, 13.5, 13.56, 14.31818,
14.7456, 16.0, 18.432, 20.0, 20.5, 24.0,
24.576, 25.0, 26.0, 27.0
Fundamental (AT-cut)
0
-40
-50
-50
+70
+125
+50
+50
60
40
25
5
ºC
ºC
ppm
ppm
Ω
pF
pF
µW
ppm
See options
See options
See options
12.000 ~ 16.000MHz
16.001 ~ 30.000MHz
30.001 ~ 40.000MHz
Standard
(See options if
other than STD)
* Please contact Abracon for other frequencies.
500
M
Ω
10nw ~ 100uw,12 points
Change in ESR (Maximum - Minimum) over DLD range < 30% ESR max.
@25°C±3°C
First year
@ 100Vdc
± 15V
ABRACON IS
ISO9001:2015
CE R TIFIED
Revised:07.29.2021
Headquarters: 5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
SMD MICROPROCESSOR CRYSTAL
ABLS7M2
PART IDENTIFICATIONS:
(left blank if standard)
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.0mm
ABLS7M2 -
Frequency in MHz
Please specify the
frequency
in
MHz.
e.g.
12.000MHz
14.31818MHz
Load Capacitance
(pF)
Please specify CL
(Minimum 8pF) in pF
or S for series
Custom ESR if other
than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
MHz -
-
-
-
Packaging
Blank: Bulk
T: Tape
&
Reel
Operating Temp.
Blank: 0°C ~ +70°C
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J: -40°C ~ +105°C
K: -40°C ~ +125°C
Freq. Tolerance
Blank: ± 50 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
(See Table 1 for details)
Blank: ± 50 ppm
U: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H:
± 35 ppm
Q: ± 100 ppm
Table 1 Available Combinations of Operating Temp. and Freq. Stability
Operating Temp.
A: -10°C ~ +60°C
Std.: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J: -40°C ~ +105°C
K: -40°C ~ +125°C
Freq. Stability
U:±10ppm
√
√
G:±15ppm
√
√
√
X:±20ppm
√
√
√
√
W:±25ppm
√
√
√
√
Y:±30ppm
√
√
√
√
√
√
H:±35ppm Std.:±50ppm Q:±100ppm
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Note: Please contact Abracon for other frequency stability and operating temperature range options.
ABRACON IS
ISO9001:2015
CE RTIFIED
Revised:07.29.2021
Headquarters: 5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
SMD MICROPROCESSOR CRYSTAL
ABLS7M2
OUTLINE DIMENSION:
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.0mm
Actual Size Comparison
ABLS
11.4 x 4.7 x 4.2 mm
ABLS7M2
7.0 x 4.1 x 2.0 mm
Dimension: inches [mm]
REFLOW PROFILE:
ABRACON IS
ISO9001:2015
CE R TIFIED
Revised:07.29.2021
Headquarters: 5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
SMD MICROPROCESSOR CRYSTAL
ABLS7M2
TAPE & REEL:
T = tape and reel (3000pcs/reel)
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.0mm
No.
A
C
D
T
F
G
H
Dimensions
(mm)
100 ± 1.0
330 ± 2.0
16.4 ± 1.0
20.4 ± 0.5
13.0 ± 0.2
20.2 min.
1.5 min.
No.
J
K
L
M
N
P
Q
R
S
Dimensions
(mm)
Ø1.5
4.0 ± 0.1
16.0 ± 0.3
7.5 ± 0.1
9.4 ± 0.1
2.5 ± 0.1
0.3 ± 0.05
8.0 ± 0.1
4.4 ± 0.1
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where
designated,
Automotive
Applications. Abracon’s products are not specifically
designed
for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high
reliability where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environ-
ment, written consent and authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO9001:2015
CE R TIFIED
Revised:07.29.2021
Headquarters: 5101 Hidden Creek Ln Spicewood TX 78669
说明The TMP275 is a 0.5°C accurate, Two-Wire, serial output temperature sensor available in an MSOP-8 or an SO-8 package. The TMP275 is capable of reading temperatures with a resolution of 0.0625°C.The ...
I read the relevant posts in the forum and set up according to the corresponding methods, but I still can't generate a txt file. There is only an out file in the debug folder of the project, but no tx...
The product function requires Ethernet communication SD/MMC and at least 2RS485 channels. I chose STM32F107 at first, mainly because of its Ethernet function.But now there are several problems. I need...
I am a newbie and I need advice from seniors. I am a student and I am currently working on a small project. I use ARM as the main control to mount FPGA as a peripheral on ARM. ARM and FPGA need to be ...
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
Due to the significant increase in electronic devices in automotive and industrial applications, the automotive and industrial markets continue to play an important role in China's electronics in...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
In recent years, lighting has become an important area that countries around the world are targeting to promote energy conservation and environmental protection. According to statistics, about 20% ...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
AD8205 is
a single-supply high-performance differential
amplifier
launched by
Analog
Devices of the United States
. The typical single-supply voltage is 5V, and its common-mode volta...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
Overview
In spectral measurement, photomultiplier tubes (PMT) and charge-coupled devices (CCD) are often used as photoelectric converters. PMT is used in slow-changing, high-precision spectral...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
Abstract: The output of high-range acceleration sensor is less than 10 mV under the excitation of small signal. The noise of traditional test system may cover such small voltage signal, so that hig...[Details]
Introduction
Nowadays, people pay more and more attention to the security alarm system, and people have higher and higher requirements for the functions and performance of the alarm. This paper prop...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]