38-A126J4 Overview

POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT

38-A126J4 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 305 V, COIL RELEASE VOLTAGE(AC): 60 V
body width46.2 mm
body height51.6 mm
Body length or diameter46.2 mm
Coil current (AC) maximum value0.03 A
Coil power5000 mW
Coil resistance15200 Ω
Maximum coil voltage (AC)452 V
Coil/Input Power TypeAC
Contact/Output Power TypeAC
Electrical life250000 Cycle(s)
Manufacturer's serial number38
Installation featuresPANEL MOUNT
physical size46.2mm X 46.2mm X 51.6mm
GuidelineUL
Relay actionMOMENTARY
Relay functionSPST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeQUICK CONNECT
Base Number Matches1
Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
The MegaCore Function in DSP builder has nothing.
There is no IP core in the MegaCore Function in DSP builder, but there is IP in the installed Quartus. How can I add the IP core in DSPbuilder? DSPbuilder is installed correctly because the sine wave ...
ljjshuishou FPGA/CPLD
STM8207 PA1 and PA2 are not working smoothly
I am using PA1 and PA2 of STM8207 as output pins, but I found that these pins are not controlled. These pins are also the input and output pins of external crystals, but in our system, no external cry...
owentangye stm32/stm8
Can the pulsating DC be directly input into the three-phase inverter bridge without filtering after rectification?
[b]As the title says, in a frequency converter, is it possible to directly input the pulsating DC into the three-phase inverter bridge without filtering after rectification? [/b]...
huahua123 Power technology
【Altera soc experience tour】+ Implementation of wireless routing design based on ad hoc network on FPGA-SOC (4)
[align=center][size=14px] IF Design of DU[/size][size=14px]CIC Design of FPGA Software Part[/size][/align] [align=center][size=14px][align=left]Cascaded Integrator Comb Filter (CIC) is a multi-rate fi...
muhan9 FPGA/CPLD
wince flash player spark example modified to display while parsing
Has anyone modified the spark example to display while parsing? If someone has modified it, can you give me some guidance? The code is a bit complicated. I hope experts who have done it can give me so...
xag1980 Embedded System
How to control some devices via Bluetooth
I want to use a single-chip microcomputer to make some intelligent control things, and hope to use the Bluetooth device on an Android phone to control it. Please give me some advice....
pangwenbin Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1467  2640  1988  872  1150  30  54  41  18  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号