EEWORLDEEWORLDEEWORLD

Part Number

Search

FKP3F014703D00MH

Description
Film Capacitor, Polypropylene, 250V, 20% +Tol, 20% -Tol, 0.0047uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size327KB,8 Pages
ManufacturerWIMA
Websitehttps://www.wima.de/
Environmental Compliance  
Download Datasheet Parametric View All

FKP3F014703D00MH Overview

Film Capacitor, Polypropylene, 250V, 20% +Tol, 20% -Tol, 0.0047uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

FKP3F014703D00MH Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid2103763274
package instruction,
Reach Compliance Codecompliant
Country Of OriginGermany
ECCN codeEAR99
YTEOL6.9
capacitance0.0047 µF
Capacitor typeFILM CAPACITOR
dielectric materialsPOLYPROPYLENE
JESD-609 codee3
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
method of packingTR, 20 INCH
positive tolerance20%
Rated (AC) voltage (URac)160 V
Rated (DC) voltage (URdc)250 V
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapeWIRE
WIMA FKP 3
Polypropylene (PP) Film and Foil
Capacitors for Pulse Applications
PCM 7.5 mm to 15 mm
Special Features
˜
Pulse duty construction
˜
Very low dissipation factor
˜
Negative capacitance change
versus temperature
˜
Very low dielectric absorption
˜
According to RoHS 2002/95/EC
D
Electrical Data
Capacitance range:
100 pF to 0.22
m
F (E12-values on request)
Rated voltages:
63 VDC, 100 VDC, 250 VDC, 400 VDC,
630 VDC, 1000 VDC
Capacitance tolerances:
±20%, ±10%, ±5%
Operating temperature range:
–55+ C to +100+ C
Test specifications:
In accordance with IEC 60384-13
and EN 131 800
Climatic test category:
55/100/56 in accordance with IEC
Insulation resistance
at +20+ C:
5 x 10
5
(mean value: 1 x 10
6
M¸)
Measuring voltage:
U
r
= 63 V: U
test
= 50 V/1 min.
U
r
100 V: U
test
= 100 V/1 min.
Test voltage:
2 U
r
, 2 sec.
Maximum pulse rise time:
1000 V/
m
sec for pulses equal to the
rated voltage
Dielectric absorption:
0.05 %
Temperature coefficient:
–200 x 10
-6
/+ C (general guide)
Dissipation factors
at +20+ C: tan
d
at f
C0.1
mF
0.1
mF
P
C
0.22
mF
3 x 10
-4
6 x 10
-4
Typical Applications
For high frequency applications e.g.
˜
Sample and hold
˜
Timing
˜
LC-Filtering
˜
Oscillating circuits
˜
Audio equipment
1 kHz
4 x 10
-4
10 kHz
5 x 10
-4
100 kHz
10
x 10
-4
Construction
Dielectric:
Polypropylene (PP) film
Capacitor electrodes:
Metal foil
Internal construction:
Voltage derating:
A voltage derating factor of 1.35 % per K
must be applied from +85+ C for DC
voltages and from +75+ C for AC
voltages.
Reliability:
Operational life 300 000 hours
Failure rateP 5 fit (0.5 x U
r
and 40+ C)
Plastic film
Metal foil electrode
Terminating wire
Mechanical Tests
Pull test on leads:
10 N in direction of leads according to
IEC 60068-2-21
Vibration:
6 hours at 10 ... 2000 Hz and 0.75 mm
displacement amplitude or 10 g in
accordance with IEC 60068-2-6
Low air density:
1kPa = 10 mbar in accordance with
IEC 60068-2-13
Bump test:
4000 bumps at 390 m/sec
2
in
accordance with IEC 60068-2-29
Packing
Available taped and reeled.
Detailed taping information and graphs
at the end of the catalogue.
Encapsulation:
Solvent-resistant, flame-retardant plastic
case with epoxy resin seal, UL 94 V-0
Terminations:
Tinned wire.
Marking:
Colour: Red. Marking: Black.
Epoxy resin seal: Yellow
For further details and graphs please
refer to Technical Information.
54
01.10
Which formaldehyde sensor is good? Which model? If you have used it, please share and discuss.
Which formaldehyde sensor is good? Which model? If you have used it, please share and discuss....
damiaa Sensor
Good design idea: "head-and-body-separated multimeter" Fluke 233
Imagine the possibilities What would you do if you could be in two places at once?The new Fluke 233 True-rms Remote Display Digital Multimeter gives you tremendous flexibility in handling those unusua...
cscl Test/Measurement
I'm a newbie, how can I port a 51 program to a 430?
Now I have a 51 program, how do I change it to a 430 program? What do I need to change? What do I need to pay attention to?...
Ben讨厌苦咖啡 Microcontroller MCU
Questions about learning Verilog
Is there a more vivid way to describe tasks and functions in Verilog hdl? I have read the book several times, but I still don't understand it. Can any expert share his experience? I would be very grat...
wall_e FPGA/CPLD
MSP430 Timer B capture issue
I am a newbie. I recently needed to measure the frequency of a square wave. I was confused and figured out a code after a long time. The result was wrong. The code is as followsCode: #includemsp430x14...
iceflasher Microcontroller MCU
[Transfer] Lifting the red underwear of foreign companies: those who want to work in foreign companies should
[align=right][float=right][url=http://www.2ic.cn/bbs/misc.php?action=viewratings&tid=335967&pid=619922][img]http://www.2ic.cn/bbs/images/default/agree.gif[/img][img]http://www.2ic.cn/bbs/images/defaul...
analogstudy Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 822  163  1871  2158  1397  17  4  38  44  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号