EEWORLDEEWORLDEEWORLD

Part Number

Search

3191BC682S035DNA1

Description
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 35V, 6800uF, STUD MOUNT, CAN, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size362KB,4 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Environmental Compliance  
Download Datasheet Parametric View All

3191BC682S035DNA1 Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 35V, 6800uF, STUD MOUNT, CAN, ROHS COMPLIANT

3191BC682S035DNA1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1653339934
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance6800 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
ESR17.2 mΩ
Manufacturer's serial number3191
Installation featuresSTUD MOUNT
negative tolerance10%
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Package shapeCYLINDRICAL PACKAGE
polarityPOLARIZED
positive tolerance30%
Rated (DC) voltage (URdc)35 V
ripple current8800 mA
surface mountNO
Terminal shapeBINDING POST
Type 3191
Aluminum Electrolytic, Screw Terminals, Switching and Audio Output
Screw Terminal Capacitors for Power Output Filtering
The low ESR of Type 3191 capacitors makes them
a great choice for output filtering in switching and
audio power supplies. It’s available with the capacitor
element potted in place for lowest cost or secured by
rill, spoon shaped dimples in the side of the can. Rilled
construction offers high vibration and shock with-
standing and excellent heat transfer for higher ripple
current.
Outline Drawing
Highlights
Stud mount available
High current application
Industrial applications
Smoothing and filtering
Audio power supplies
Specifications
Operating Temperature:
Rated Voltage:
Capacitance Range:
Capacitance Tolerance:
Ripple Current Multipliers
–40 to + 85 ºC
7.5 Vdc to 55 Vdc
2700 µF to 150000 µF
–10 to + 30%; –10 to +50%; ±20%
Ambient Temperature
Temperature
I
R
Multiplier
45 ºC
2.24
60 Hz
0.90
55 ºC
2.00
120 Hz
1.00
65 ºC
1.73
300 Hz
1.05
75 ºC
1.41
85 ºC
1.00
Frequency
Frequency
I
R
Multiplier
1000 Hz
≥10
Khz
1.10
1.15
Life Test:
Shelf Life:
Vibration:
Complies with the EU Directive
2002/95/EC requirement restricting
the use of Lead (Pb), Mercury (Hg),
Cadmium (Cd), Hexavalent chromium
(Cr(VI)), PolyBrominated Biphenyls
(PBB) and PolyBrominated Diphenyl
Ethers (PBDE).
Endurance, 1500 h at rated voltage and 85 ºC
Δ Capacitance: ±10%
ESR ≤ 200% of limit
DCL ≤ 100% of limit
Storage, 500 h at 85 ºC
Δ Capacitance: ±10%
ESR ≤ 175% of limit
DCL ≤ 200% of limit
10 to 500 Hz, 0.75 mm or 10 g* if less,
3 directions, 2 h ea
Δ Capacitance: ±5%
no visible damage or leakage
*15 g if rilled construction
CDM Cornell Dubilier • 140 Technology Place. • Liberty, SC • 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
Analog Devices' Two-Wire Loop-Powered Transmitter Solution
[color=#000000][size=14px][b]Industrial Loop-Powered Transmitter System Principles and Trends[/b][/size][/color] [align=left]Contemporary field instruments, also known as smart transmitters, are micro...
苏莎莎 ADI Reference Circuit
TCP Hardware Protocol Stack Data--W5500
TCP Hardware Protocol Stack Data--W5500...
heping88888 Industrial Control Electronics
sht20 temperature and humidity sensor exchange area
[color=rgb(0,0,0)][backcolor=rgb(255,255,255)]Hello everyone in the forum, who has used the sht20 temperature and humidity sensor? If you have a program that can be used to adjust it, please share it....
dingshidong MCU
【TI's First Low Power Design Competition】Sacq's Wolverine (6): LCD1602 display under Energia
[i=s]This post was last edited by sacq on 2014-10-15 23:31[/i] There are already many LCD1602 routines in Energia's routines. When using Wolverine to drive LCD1602, these routines need to be slightly ...
sacq Microcontroller MCU
If two nodes are 100 meters apart, what aspects can be used to ensure the maximum transmission rate, and what is the maximum rate that can be achieved?
If two nodes are 100 meters apart, what aspects can be used to ensure the maximum transmission rate, and what is the maximum rate that can be achieved?...
洋洋阳阳 stm32/stm8
[Xiao Meige SOPC learning notes] How to use the system clock
[i=s] This post was last edited by Core Route Runner on 2017-4-14 13:48 [/i] [b][align=center][b][size=5]Add a surging heart to NIOS II CPU - Use of system clock [/size][/b][/align] [/b][color=#000][s...
芯航线跑堂 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2662  916  831  798  2106  54  19  17  43  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号