AEC - Q200
Qualified
ZCM Series Datasheet
SMD Precision Metal Film Resistors | MELF Style
ORDERING CODE-Example
New SAP Part Nr.:
APPLICATIONS
Automotive
Charger
Power Supply
Industrial
ZCM
Serie
207
Power rating
204 = 0,4W
207 = 1,0W
F
Tol.
B
= ±0,1%
C
= ±0,25%
D
= ±0,5%
F
= ±1%
G
= ±2%
J
= ±5%
K
Pack-Code
K
= Blister
tape reel
E
TCR
C
= ±15ppm
D
= ±25ppm
E
= ±50ppm
F
= ±100ppm
07-
Forming type
07-
= 07 inch
(Reel diameter)
or
13-
= 13 inch
(Reel diameter)
1K
R Value
AA
Special
AA
= Standard
Alternative Energy
Home Appliances
FEATURES
Precision MELF resistor
Advanced MELF technology
Excellent stability in different environmental conditions
Best in class pulse load capability
AEC – Q200 Qualified
Intrinsic sulfur resistance
RoHs & REACH Compliant
Historical VTM Part Nr.:
ZC
Type
0207
Size
F
Tol.
K
K = Blister tape reel
E
TC
07
Reel diam.
1K
R Value
ELECTRICAL SPECIFICATIONS
Type
Historical Part Number
Nominal Power Rating
Resistance Range
E-Series
Tolerances
Temperature Coefficient
IEC60115-1 clause 4.2 ; 4.8
(+20 / -55[°C] and (+20 / +125[°C])
ZCM204
SMD
ZCM207
ZC0207
ZC0204
P
70
[W]
[Ω]
±[%]
±[10
-6*
K
-1
]
[ºC]
[ºC]
[AC
or
DC]
RMS
[V]
RMS
0,4
0R22 … 10M
(Other values upon request)
1,0
0R16 … 10M
E24 / E96 / E192
B = 0,1% , C = 0,25% , D = 0,5% , F = 1% , G = 2% , J = 5%
Depends on the value, please check the table below
-55 … +155
155
200
300
350
500
Working Temperature Range
Permissible film temperature
(
ϑ
F max.)
Max. Working Voltage
Dielectric Withstanding Voltage
IEC115-1 clause 4.7 (1[min])
DIMENSIONS [mm]
Type
ZCM204
ZCM207
ZC0207
Recommended solder pads dimensions
Type
ZCM204
ZCM207
Wave soldering
Reflow soldering
I
1,5
2,4
a
1,5
2,3
b
1,8
2,6
c
4,5
7,0
I
1,7
2,6
a
1,2
2,0
b
1,6
24
c
4,1
6,6
File Nr. 3900.18-450.113.16 |
Revision: 201710
Historical
P/N:
ZC0204
L
Ø
D
L
1
Ø
D
1
A
0,80
±0,10
1,25
±0,2
MASS
(mg)
3,6
+0 /-0,2
1,4
+0 /-0,1
1,8
min.
5,8
+0 /-0,3
2,2
±0,2
2,6
min.
D
+0 /-0,15
D
+0 /-0,2
22
77
1
1
ZCM Series Datasheet
PERFORMANCE DATE
Type
Historical Part Number
Climatic Category
Short Time Overload
ZCM204
ZC0204
55/155/56
0,03 (≤1M) ; 0,1 (>1M)
0,05 (≤1M) ; 0,1 (>1M)
0,15
0,15
0,15
0,3
≤ 0,1
0.05 (10R≤1M)
0.1 (10R≤1M)
0.15 (<10R) ; 0.1 (10R≤1M) ; 0.25 (>1M)
0.3 (<10R) ; 0.2 (10R≤1M) ; 0.5 (>1M)
0.25
0.5
0.15 (<10R) ; 0.1 (10R≤1M) ; 0.25 (>1M)
0.3 (<10R) ; 0.2 (10R≤1M) ; 0.5 (>1M)
0,15 (≤ 1M) ; 0,25 (>1M)
0.05 (10R≤1M)
0.1 (10R≤1M)
0.15 (≤1M) ; 0.5 (>1M)
0.3 (≤1M) ; 1 (>1M)
0,25 (≤1M) ; 0,5 (>1M)
0,5 (≤1M) ; 1 (>1M)
0,15 (≤1M) ; 0,5 (>1M)
0,3 (≤1M) ; 1 (>1M)
0,25 (≤ 1M) ; 1 (>1M)
ZCM207
ZC0207
0,03 (≤1M) ; 0,15 (>1M)
0,05 (≤1M) ; 0,15 (>1M)
0,25
0,5
0,15
0,3
Standard
operation
IEC60115-1 clause 4.13
Power
(U=2,5*
, ≤2*
U
max,
5
[s])
operation
Standard
Single pulse high voltage overload
operation
IEC60115-1 clause 4.27
Power
(U=10*
,
Severity 4, 10 pulses 10[µs]/700[µs]
operation
±[%]
±[%]
±[%]
[10 h ]
-9
-1
Periodic electric overload
IEC60115-1 clause 4.39
(U=15*
,
0.1[s]on, 2.5[s]off,1000 cycles
Failure Rate
(Total,
ϑ0 ,
max, 60[%] cont. lev.)
Standard
operation
Power
operation
Endurance at 70ºC,
(U=
Precision
operation
Standard
operation
Power
operation
±[%]
±[%]
±[%]
±[%]
IEC60115-1 clause 4.25.1
U
max,
, 1,5[h]ON ; 0,5[h]OFF)
Endurance at upper Category Temp.
IEC60115-1 clause 4.25.3
( 1000[h]
1000h
8000h
1000h
8000h
1000h
8000h
125ºC
155ºC
Damp Heat, Steady State
IEC60115-1 clause 4.24
(40 [°C], 93 [% r.h.], 56[d])
±2
±3
±[%]
±[%]
±[%]
-55~125ºC
-55~155ºC
Damp Heat, Steady State, Accelerated
IEC60115-1 clause 4.37
(85 [°C], 85 [%RH], U = 0.3*
±2
±5
0,25 (≤ 1M) ; 2 (>1M)
0,15 (≤ 1M) ; 0,25 (>1M)
0,5
0,05 (≤ 1M) ; 0,1 (>1M)
0,1 (≤ 10R) ; 0,05 (>10R)
0,5 [2 kV]
No flash over or breakdown
No burning after 30[s]
0,5 (≤ 1M) ; 2 (>1M)
0,25
0,5
0,05
0,1 (≤ 10R) ; 0,05 (>10R)
0,5 [4 kV]
)
Temperature Cycling
( 30[min] each , 1000 cycles)
IEC60068-2-14 ; IEC60115-1 clause 4.19
Vibration
IEC60068-2-6 ; IEC60115-1 clause 4.22
(10;2000[Hz],
≤1,5[mm]
, or
≤200[m/s
] 7,5[h])
2
±[%]
±[%]
±[%]
Resistance to Soldering Heat
IEC60115-1 clause 4.18
±5
±1
(260 [°C], 10 [s])Solder bath method
Electrostatic Discharge
Voltage proof
U
RMS
=U
INS
, 60 [s]
IEC60115-1 clause 4.38 ; IEC61340-3-1
( 3 positives + 3 negatives discharges)
IEC60115-1 clause 4.7
Flammability
Solderability
(235 [ºC] 2
±3
±0,2
IEC60115-1 clause 4.35, IEC60695-11-5
Needle flame test, 10[s]
IEC60068-2-20 ; IEC60115-1 clause 4.17
[s],SnAg
3
Cu
0.5
or SnAg
3.5
)
≥ 95% covered, no visible damage
Component Resistance to Solvents
(50[ºC] method 2)
IEC60068-2-45 ; IEC60115-1 clause 4.29
No visible damage
File Nr. 3900.18-450.113.16 |
Revision: 201710
Resistance to solvents of Marking
(50[ºC] method 1)
IEC60068-2-45 ; IEC60115-1 clause 4.30
Marking visible , no visible damage
Color code
Marking
IEC60062
NOTES: MARKING [COLOR CODE]:
•
ZCM204
Color code marking is applied according to IEC 60062 in four bands (E24 series) for 5 % tolerance, or in five bands (E96 or E192 series). Each color band appears as a single solid
line, voids are permissible if at least
2/3
of the band is visible from each radial angle of view. The last color band for tolerance is approximately 50 % wider than the other bands.
solid line, voids are permissible if at least
2/
of the band is visible from each radial angle of view. The last color band represents the TCR for resistors with TCR
≤50
ppm/K and nominal tolerance
≤1
%.
3
•
ZCM207 Color code marking is applied according to IEC 60062 in four (E24 series) or six bands (E96 series). Each color band appears as a single
Zero ohm jumpers are marked with one centered black band.
2
1
ZCM Series Datasheet
TEMPERATURE COEFFICIENT
ZCM204
ZCM207
Resistance range
Tolerance
TCR
E-Series
0R16 … 0R91
± 5%
0R22 … 0R91
± 100 ppm/K
E24
0R22 … 0R91
± 2%
0R82… 10M
1R… 10M
± 1%
E24 / E96
± 50 ppm/K
10R… 1M65
1R… 2M21
± 0,5%
E24 / E192
10R… 1M65
43R… 1M
± 0,5%
22R… 1M65
43R… 1M
± 0,25%
± 25 ppm/K
E24 / E192
22R… 1M65
43R… 1M
± 0,1%
Notes :
10R… 221K
± 0,5%
•
ZCM204 - The color of the body coating is light green for
100R… 511K
for a temperature coefficient of ±50 ppm/K or ±100 ppm/K, pink for ±25 ppm/K, or violet for ±15 ppm/K.
jumpers and
•
ZCM207 - TCR ±10 ppm/K and
221K
22R…
±5 ppm/K in resistance
100R… 511K
100kΩ on request.
0,25%
range 100Ω to
±
± 15 ppm/K
E24 / E192
•
Zero ohm jumper - Are marked with one centered black band.
511K
43R… 221K
100R…
± 0,1%
Jumper
I
max
= 3A
Jumper
I
max
= 5A
≤ 10 mΩ
NOTES: RESISTOR BODY COLOR CODE:
•
The body coating color is light green for jumpers and for a temperature coefficient of ±50 or 100 [ppm], pink for ±25[ppm] and violet for ±15[ppm]
MAXIMUM RESISTANCE CHANGE AT RATED DISSIPATION
OPERATION MODE
Rated Power dissipation P
70
[W]
Operating temp. range [ºC]
Permissible film temperature ϑF Max [ºC]
Resistance range
1000h
Max. Resistance drift [%]
8000h
[ΔR/R]
225 000h
•
PRECISION
0,07
-10 to 85
85
10R – 1M
≤0,05
≤0,1
≤0,25
ZCM204
STANDARD
0,25
-55 to 125
125
R22 – 1M
≤0,15
≤0,3
≤0,75
POWER
0,4
-55 to 155
155
R22 – 10M
≤0,25
≤0,5
-
PRECISION
0,125
-10 to 85
85
100R – 511K
≤0,05
≤0,1
≤0,25
ZCM207
STANDARD
0,4
-55 to 125
125
1R0 – 1M
≤0,15
≤0,3
≤1,0
POWER
1,0
-55 to 155
155
1R0 – 1M
≤0,25
≤0,5
-
A suitable low thermal resistance of the circuit board assembly must be safeguarded in order to maintain the film temperature of the resistors within the specified
limits.
PERFORMANCE GRAPH’s
Derating – Precision Operation
Derating – Standard Operation
Derating – Power Operation
Non- Linearity
File Nr. 3900.18-450.113.16 |
Revision: 201710
3
1