Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
M
Ω
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
Table 1
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
Operation Mode
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MH z
Please specify the frequency
in x x .x x x x M Hz.
e .g . 14.3181MHz
MHz -
-
-
-
-
-
-
P a c k a g in g
Blank: Bulk (std.)
T: Tape & Reel
(For MJ option only)
Q u a lit y F a c t o r * * *
Minimum
QXXXk
Value
L o a d Capacit anc e (pF)
Please specify CL
(Minimum 10 pF) in pF or
S fo r series
Custo m E SR if other
than st a n d a r d
R□
□: Specify
a value in
Ω
(e .g .: R40)
Operating Temp.
A: -10°C ~ + 60° C
B: -20°C ~ + 70° C
C: -30°C ~ + 70° C
N: -30°C ~ + 85° C
D: -40°C ~ + 85° C
Valu e Added
I
V
QXX
MJ
Operation Mode
Fund. AT > 24MHz
F
FB
O
Freq. Tolerance
1: ± 10 pp m
7: ± 15 pp m
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq . St abilit y
Option s fo r A T -
Cut only *
U * * : ± 1 0 p pm
G: ± 15 ppm
X: ± 20 ppm
W : ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 5 0 p pm
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriat e code numbers for
other trimmed lengths not liste d.
(e.g. Q14 for 0.14 inch (3.55 mm))
Fund. BT>24MHz
3rd OT>66MHz
Insulator Tab
Vinyl Sleeve
T rimmed lea ds
See Ta ble 2
Metal jacket
NOTE:
*:Fr equency Stability ± 100
ppm max at -10 to +60C only
for BT cut.
** : -10 to +60C only.
*** : Quality factor must be
ac companied by a k value
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Tape and reel packaging applies only to MJ (metal jacket) option
E
1.75±0.10
E2
22.25 MIN.
F
11.5±0.10
P2
2.00±0.10
ØD0
1.50±0.10
P0
4.00±0.10
W
24.00±0.30
Dimensions: mm
ATTENTION:
Abracon products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon is required. Please contact Abracon for more information.
I want to make an intelligent lighting system . The specific idea is as follows: use two human infrared sensors to make a monitoring point. When the first sensor detects a person passing by, it sends ...
To be honest, I was very surprised by this kind of labeling. I know that no matter which series of FPGA, high, medium or low, the latest ones are Cyclone V, Arria V, or stratix V. This leapfrog labeli...
I am a beginner in microcontrollers and want to make a development board myself, but I don't know where to start. Could the senior give me some advice? I would be very grateful....
scancodetovirtualkey, I looked at the source code and it is calling *puiVk = MapVirtualKey(*puiSc, MAP_SC_TO_VK); but I can't find this function. Does anyone know, please help me solve it.```...
I know that the second parameter is the code to be executed, but these codes are just some numbers. How can I match these numbers with specific iocontrol functions? What is the specific matching proce...
Designers use PSpice primarily to simulate analog circuits. However, it can also be used to simulate digital filters. The main components in a digital filter are delay elements, adders, and multipl...[Details]
Medicines are special commodities. If patients are given the wrong medicine, fake medicine, inferior medicine or expired medicine, it will pose a threat to people's health and lives.
In recent...[Details]
The particularity of portable medical devices determines that they should be user-friendly, must work in a sterile environment, and occupy little space and consume low energy.
At the same time, por...[Details]
Many medical applications require portable, self-powered devices that do not require external power and data cables. The most obvious example is a portable data logger that patients carry with them to...[Details]
The hardware circuit principle is shown in Figure 1. In the specific design, each part should consider the anti-interference problem to minimize the impact of interference on the performance of the...[Details]
Demand Analysis
In an era of rapid information development, the process of electronicization of the financial system has also been greatly accelerated. As a platform that provides services 24 ...[Details]
The microwave multifunctional therapeutic device uses microwave radiation for heating treatment, which can achieve the effects of sterilization and blood circulation. Using microwaves to directly c...[Details]
Abstract:
This paper introduces the excitation system designed for 3/3 phase double winding induction generator, which is composed of DSP and FPGA. The interface circuit of the control sys...[Details]
Automatic target recognition (ATR) algorithms usually include algorithms for automatically detecting, tracking, identifying, and selecting attack points for targets. The complexity of the battlefi...[Details]
Billboards are information display terminals for the public, with a wide range of civil and commercial values. However, most of the information displayed on billboards is currently solidified in th...[Details]
The full name of RFID is Radio Frequency Identification, which uses radio frequency to realize data transmission between programmable controller (PLC) or microcomputer (PC) and identification, ther...[Details]
0 Introduction
One of the basic tasks of machine vision is to obtain image information from the camera and calculate the geometric information of objects in three-dimensional space, so as ...[Details]
0 Introduction
A gyroscope is an instrument that can accurately determine the direction of a moving object. It is an inertial navigation instrument widely used in modern aviation, navigation...[Details]
Fairchild Semiconductor provides the industry's smallest power management solution FAN5902 for 3G mobile phone and wireless data card designers. This RF power DC-DC converter uses a 12-bump 0.5mm p...[Details]
In the past one or two years, driven by Apple's iPhone, the smartphone market has expanded rapidly. An important feature of portable products such as smartphones is that they have more and more fun...[Details]