L13-B2-26-410-H62-K3

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L13-B2-26-410-H62-K3 Overview

Magnetic Circuit Breaker,

L13-B2-26-410-H62-K3 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7347453940
Reach Compliance Codecompliant
Country Of OriginMexico
YTEOL7.3
Actuator typeROCKER
Other featuresSTANDARDS: MIL-PRF-55629, MIL-STD-202
body width57.15 mm
body height49.4 mm
Body length or diameter92.58 mm
circuit functionSERIES TRIP
Circuit protection typeMAGNETIC CIRCUIT BREAKER
Environmental characteristicsMOISTURE RESISTANT
Installation featuresPANEL MOUNT
Number of poles3
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Rated breaking capacity5000 A
Rated current1 A
Rated voltage (AC)120 V
GuidelineEN; TUV; UL
surface mountNO
Terminal shapeSCREW
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
There is a serial communication protocol that needs to be analyzed and cracked, and I am looking for help from experts
There is a serial communication protocol that needs to be analyzed and cracked. I am looking for help from experts! Thank you! to:hawking20001981 (Dongdong VC++ Primer) Please contact me as soon as po...
simon_eun Embedded System
[Question] WINCE implements HIVE problem 3: Have you encountered such an error? Invalid size specification (e32_vsize == 0) in m
[Question] Problem 3 of HIVE implementation in WINCE: Have you encountered such an error? Invalid size specification (e32_vsize == 0) in module boot.hv [color=#33CCCC]I. Environment description[/color...
liguangemail Embedded System
Altera BlockRAM related settings
Does Altera's BlockRam have a Read before Write function like Xilinx? That is, when WriteEN is pulled up, the data in the Address will be output first and then written. In Quartus IP, I only found Rea...
simonsss FPGA/CPLD
When the operating system is vxworks, how can I check the performance of each function defined when testing c?
There are corresponding tools to view it under Windows, but I don't understand it under VxWorks...
coolbi5 Real-time operating system RTOS
Which expert can recommend an introductory book on basic ARM development?
Can anyone recommend an introductory book on basic ARM development? Or can someone write a cradle-to-grave learning book on ARM development like Hou Jie did :)...
pcblayout ARM Technology
4-layer board design schematic problem
[i=s] This post was last edited by okhxyyo on 2015-5-13 09:42 [/i] As shown in the figure, part of the circuit,I am very confused. For this circuit suitable for a 12V adapter, why do we need a DC-DC c...
okhxyyo PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 905  755  1828  2856  916  19  16  37  58  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号