Description
fuse glass 1.25a 250vac 5x20mm
CategoryCircuit protection   
File Size126KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

BK/S506-1.25A Overview

fuse glass 1.25a 250vac 5x20mm

BK/S506-1.25A Parametric

Parameter NameAttribute value
Datasheets
S506 Series
Product Photos
S506-R Series
Other Related Documents
S50x, GDC Series Part Numbering/RoHS
PCN Obsolescence/ EOL
S50x Series Non-Rohs 01/Aug/2011
PCN Design/Specificati
S506 Ratings 4/Aug/2008
Standard Package100
CategoryCircuit Protecti
FamilyFuses
PackagingBulk
Fuse TypeCartridge, Glass
Current Rating1.25A
Voltage Rating - AC250V
Voltage Rating - DC-
Response TimeSlow
Package / Case5mm x 20mm
Mounting TypeHolde
Breaking Capacity @ Rated Voltage35A
Melting I²6.7
ApprovalsBSI, CCC, CSA, cULus, IMQ, MITI, SEMKO, VDE
Operating Temperature-
Col-
Size / Dimensi0.205" Dia x 0.787" L (5.20mm x 20.00mm)
DC Cold Resistance0.045 Ohm
Other NamesBK-S506-1-25AS506-1.25A
5mm x 20mm Fuses
S506 Series, Time Delay, Glass Tube
Description
• Time delay, low breaking capacity
• Optional axial leads available
• 5mm x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2 (32mA-10A)
S506 ELECTRICAL CHARACTERISTICS
2.1 In
2.75 In
4 In
10 In
In
max
min
max
min
max
min
max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec 10 ms 300 ms
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
8A-15A
2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
RoHS
2002/95/EC
Dimensions
Drawing Not to Scale
Agency Information
• UL Recognized Card: (32mA-15A) Guide JDYX2,
File E19180
• CSA Component Acceptance: File 53787
• cURus Recognition: Guide JDYX8, File E19180
• SEMKO Approval, 32mA-10A
• VDE Approval, 32mA-10A
• BSI Approval, 32mA-10A
• IMQ Approval, 32mA-10A
• MITI Approval, 32mA-6.3A
• CCC Approval, 32mA-6.3A
Ordering
• Specify packaging, product, and option code
• For -R option, drop mA or A from product code
(i.e. S506-2-R)
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
Interrupting Rating
at Rated Voltage (50Hz)
AC
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
40A
50A
63A
80A
100A
125A
125A
• Ratings above 6.3A have a 0.8mm diameter lead
• With TR2 packaging code, lead wire length is 19.05mm
SPECIFICATIONS
Product Code
S506-32mA
S506-40mA
S506-50mA
S506-63mA
S506-80mA
S506-100mA
S506-125mA
S506-160mA
S506-200mA
S506-250mA
S506-315mA
S506-400mA
S506-500mA
S506-630mA
S506-800mA
S506-1A
S506-1.25A
S506-1.6A
S506-2A
S506-2.5A
S506-3.15A
S506-4A
S506-5A
S506-6.3A
S506-8A
S506-10A
S506-12.5A
S506-15A
Typical DC
Cold Resistance
(ohms)*
21.0
13.90
9.24
6.96
4.42
2.74
1.97
1.27
1.00
0.640
0.450
0.308
0.183
0.186
0.128
0.062
0.045
0.038
0.028
0.023
0.017
0.012
0.008
0.008
0.006
0.004
0.004
0.004
Minimum
Pre-Arching I
2
t
(A
2
Sec) AC†
0.0014
0.0034
0.006
0.012
0.015
0.022
0.034
0.052
0.078
0.17
0.41
0.61
0.67
1.0
2.2
2.7
6.7
9.7
15
25
51
88
150
214
192
420
812
1029
Typical
Voltage
Drop (mV)‡
1050
920
800
760
580
490
390
320
340
270
250
210
140
150
75
80
70
70
68
68
66
66
66
60
55
54
45
73
* DC Cold Resistance (Measured at <10% of rated current)
† Minimum Pre-Arching I
2
t (Measured at 10 In and rated voltage)
‡ Typical Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current)
Ask an expert to install CYGWIN
I would like to ask for the complete installation tutorial of CYGWIN. Why do I always encounter errors during installation and cannot proceed?...
cxsgo Linux and Android
What is FRAM? Why should I integrate FRAM into my system?
FRAM, also known as Ferroelectric Random Access Memory, is a memory technology that combines the non-volatility of Flash with the flexibility and low power consumption of SRAM. MSP430 ultra-low-power ...
Aguilera Microcontroller MCU
How to achieve more accurate uS or mS level delay when writing the underlying driver of wince?
For example, I want a GPIO to be set to a high level first, and then become a low level after 2uS....
picmcu Embedded System
Is VxWorks CPU scheduling time considered a critical resource?
After obtaining the corresponding resources, the task changes from the blocked state to the ready state, and then waits for the CPU to execute it. So, is the execution time slice of this CPU considere...
wangxiaoyu Real-time operating system RTOS
Why can't I install my own custom SDK?
Every time at the end of the installation, an error prompt dialog box appears: ToolsMsmCA(Error):Setup package issue: Xml file not found: Then the progress bar has the legendary automatic rolling back...
zxs72 Embedded System
Has anyone used the ST7576 128*64 LCD?
Has anyone used the ST7576 128*64 LCD?Could you please send me a Datasheet? Thanks!...
academic 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1154  2281  1372  468  2893  24  46  28  10  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号