EEWORLDEEWORLDEEWORLD

Part Number

Search

315VXS330MOOESN22X45

Description
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 315V, 330uF, THROUGH HOLE MOUNT, CAN, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size197KB,2 Pages
Manufacturerrubycon
Websitehttp://www.rubycon.co.jp/cn/
Environmental Compliance
Download Datasheet Parametric View All

315VXS330MOOESN22X45 Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 315V, 330uF, THROUGH HOLE MOUNT, CAN, ROHS COMPLIANT

315VXS330MOOESN22X45 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1009773283
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
capacitance330 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
JESD-609 codee3
leakage current0.96724 mA
Manufacturer's serial numberVXS
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Package shapeCYLINDRICAL PACKAGE
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)315 V
ripple current1450 mA
surface mountNO
Delta tangent0.2
Terminal surfaceTin (Sn)
Terminal shapeSNAP-IN
LARGE CAN TYPE ALUMINUM ELECTROLYTIC CAPACITORS
VXS
VXS
SERIES
NEW
105℃ 5000hour, Charge-Discharge Facility, Snap-in Terminal Type
◆FEATURES
Load Life : 105℃ 5000 hours.
RoHS compliance.
ΔV=
Specified the endurance of 100milion times Charge-Discharge load.
◆SPECIFICATIONS
Items
Category Temperature Range
Rated Voltage Range
Capacitance Tolerance
Characteristics
−25∼+105℃
315∼450V.DC
±20%
(20℃,
120Hz)
I=3
CV (After 5 minutes application of rated voltage)
Leakage Current(MAX)
I=
Leakage Current
(μA)
(V)
Rated Voltage
tanδ
(V)
Rated Voltage
Z
(−25℃) (20℃)
/Z
C=
Rated Capacitance
(μF)
315∼450
0.20
315∼450
8
V=
Rated Voltage
(V)
(tanδ)
Dissipation Factor(MAX)
(20℃,
120Hz)
(120Hz)
Impedance Ratio(MAX)
After applying the following charge discharge load for 100milion times , the capacitors shall meet the following requirements.
Charge voltage
Discharge voltage
Rated voltage
VR[V]
Rated Voltage
-150V VR-150 [V]
R
V
V
R
- V
Charge-Discharge endurance
Charge-Discharge frequency
Charge-Discharge Resistance
Capacitance Change
Dissipation Factor
Leakage Current
Refer to Standard Size table
Refer to Standard Size table
Within ±20% of the initial value.
Not more than 200% of the specified value.
Not more than the specified value.
R
+D.U.T
After applying rated voltage with rated ripple current for 5000 hours at 105℃, the capacitors shall meet the following requirements.
Within ±20% of the initial value.
Not more than 200% of the specified value.
Not more than the specified value.
Endurance
Capacitance Change
Dissipation Factor
Leakage Current
◆MULTIPLIER FOR RIPPLE CURRENT
 Frequency coefficient
Frequency
(Hz)
◆OPTION
60
120
1.00
300
1.16
500
1.20
1k
10k≦
Pet sleeve without plate
1.30 1.40
PVC Sleeve without plate
PVC Sleeve with plate
Code
EFC
OOE
Blank
315∼
Coefficient
0.80
450WV
◆PART NUMBER
□□□
Rated Voltage
VXS
Series
□□□
Rated Capacitance
Capacitance Tolerance
□□□
Option
SN
Terminal Code
D×L
Case Size
[Popular Science] How does alternating current become direct current?
[Popular Science] How does alternating current become direct current?...
aigtekatdz Test/Measurement
XDS510 USB2.0, CCS2.2 connection f2812 error
I used CCS to connect to the DSP development board some time ago and there was no problem. But recently, I can't connect to the same development board. The error message is Can't Initialize target cpu...
benbeu Microcontroller MCU
[PCB] Analysis of key points of PCB design
[PCB] Analysis of PCB design points In today's society, a large number of electronic products are widely used in our daily work and life, so their reliability needs to be guaranteed. Most electronic s...
pcb2015 PCB Design
Google's high-altitude hot air balloon project Project Loon
Beijing time, June 25, according to foreign media reports, Google[font=宋体]officially recently released several dynamic pictures of the Project Loon project. [align=left][size=14px]Last week, [font=Tim...
qwqwqw2088 Energy Infrastructure?
How to measure AC signals
The signal collected by the current transformer and voltage transformer is an AC signal, but the AD of the microcontroller can only convert DC signals, so how to measure the AC signal? 1. Is it necess...
bigbat Power technology
Research on DSP online UPS uninterruptible power supply control system
[size=4] With the popularization of computers and the widespread application of information processing technology, uninterruptible power supplies (UPS) play an important role in connecting critical lo...
fish001 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 690  1782  238  2551  1896  14  36  5  52  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号