EEWORLDEEWORLDEEWORLD

Part Number

Search

2129-N2-33-30

Description
Card Edge Connector, 58 Contact(s), 2 Row(s), Female, Straight, Solder Terminal
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerE Connector Solutions
Download Datasheet Parametric View All

2129-N2-33-30 Overview

Card Edge Connector, 58 Contact(s), 2 Row(s), Female, Straight, Solder Terminal

2129-N2-33-30 Parametric

Parameter NameAttribute value
Objectid1970373976
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.18 mm
Termination typeSOLDER
Total number of contacts58
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
Failed to use IImage component in WINCE6
I use JPG images in my application and use the IImage interface. However, the image cannot be displayed successfully. I found through debugging that the program returns a failure when it runs to the f...
loaddd Embedded System
Which company's products are usually used for ECUs in cars?
Which company's products are usually used for ECUs in cars?...
bairubing Automotive Electronics
What are the main advantages and basic principles of LDC1314?
Please help me...
子陶 Electronics Design Contest
J-Link_UG_V2.3.pdf
J-Link_UG_V2.3.pdf...
yuandayuan6999 MCU
Question: Industrial Ethernet VLAN division and its efficiency
1. In a 100M switch, multiple VLANs are configured. Do these VLANs share the 100M bandwidth or have exclusive use of it? 2. Two VLANs are set up, namely VLAN1 and VLAN2. A port in VLAN1 is set as Hybr...
eeleader Industrial Control Electronics
EEWORLD Assessment Expert Rules (Effective from now on)
[align=left][size=4]In order to better standardize and manage the EEWORLD assessment expert team and improve the quality and level of assessment experts, the "EEWORLD Assessment Expert Application and...
okhxyyo Suggestions & Announcements

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1130  830  650  1178  1174  23  17  14  24  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号