EEWORLDEEWORLDEEWORLD

Part Number

Search

2132-N1-17-60

Description
64 CONTACT(S), FEMALE, RIGHT ANGLE SINGLE PART CARD EDGE CONN, SOLDER
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerE Connector Solutions
Download Datasheet Parametric View All

2132-N1-17-60 Overview

64 CONTACT(S), FEMALE, RIGHT ANGLE SINGLE PART CARD EDGE CONN, SOLDER

2132-N1-17-60 Parametric

Parameter NameAttribute value
Objectid1970687096
Reach Compliance Codeunknown
ECCN codeEAR99
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.175 mm
Termination typeSOLDER
Total number of contacts64
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
91program, yashi experts, please take a look at the implementation of EventModify function
There is a backlight dialog box in the display of the control panel. Here, only the registry change is implemented. Now I want to control the backlight here. I found the implementation code in screen....
hanbin Embedded System
Design and implementation of single chip caller display
Abstract: This paper introduces a caller ID display that uses the AT89C52 single-chip microcomputer to receive and display the caller ID of a phone. The display receives the caller ID information tran...
rain MCU
Cracking the bandwidth and options of RGUAN DS1000Z and DS2000A series oscilloscopes
Since I started my internship at the end of last year, I have felt that analog small signal conditioning is my weak link, so I want to go back home after get off work at night to make up for it. I dec...
qq849682862 Integrated technical exchanges
TI Wireless MCU Offline Automatic Programming Instructions
In order to solve the problem of slow burning speed and difficulty in protecting intellectual property rights when using emulators in mass production, an offline automatic burning tool is now provided...
Jacktang RF/Wirelessly
Commonly used ARM instruction sets and assembly
Simple explanation of various commands, good reference material...
wokao55555 MCU
Can this circuit be modified to be electronically controlled?
This is a robot relay control circuit! I want to modify it with an electronic circuit! Is it possible? (The original position of the robot is at point A, position XW1. After the start button is presse...
到处看看 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1207  1676  1091  2014  429  25  34  22  41  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号