EEWORLDEEWORLDEEWORLD

Part Number

Search

1812Y1K00152MAT

Description
Ceramic Capacitor, Multilayer, Ceramic, 1000V, 20% +Tol, 20% -Tol, C0G, 30ppm/Cel TC, 0.0015uF, Surface Mount, 1812, CHIP, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size562KB,9 Pages
ManufacturerKnowles
Websitehttp://www.knowles.com
Environmental Compliance
Download Datasheet Parametric View All

1812Y1K00152MAT Overview

Ceramic Capacitor, Multilayer, Ceramic, 1000V, 20% +Tol, 20% -Tol, C0G, 30ppm/Cel TC, 0.0015uF, Surface Mount, 1812, CHIP, ROHS COMPLIANT

1812Y1K00152MAT Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1469804558
package instruction, 1812
Reach Compliance Codecompliant
Country Of OriginMainland China
ECCN codeEAR99
YTEOL7.5
capacitance0.0015 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
JESD-609 codee3
Manufacturer's serial number1812
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
method of packingTR, 7 INCH
positive tolerance20%
Rated (DC) voltage (URdc)1000 V
GuidelineAEC-Q200
size code1812
surface mountYES
Temperature characteristic codeC0G
Temperature Coefficient30ppm/Cel ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Terminal shapeWRAPAROUND
Surface mount capacitors
1.1 to 1.3
1.1 - Production process flowchart
Ceramic powder
preparation
Electrode ink
material
1.2 - Syfer reliability grades
High reliability
(space quality)
Space
Grade
ESCC 3009
(1)
MIL Grade
(2)
IECQ-CECC
(3)
AEC-Q200
(4)
Standard components
Multilayer build
(wet process)
Fire
Standard
reliability
Rumble
Notes:
(1) Space grade tested in accordance with ESCC 3009. Refer to Syfer
specification S02A 0100.
Internal inspection
(2) MIL Grade. Released in accordance with US standards available on
request.
(3) IECQ-CECC. The International Electrotechnical Commission (IEC)
Quality Assessment System for Electronic Components. This is an
internationally recognised product quality certification which
provides customers with assurance that the product supplied
meets high quality standards.
View Syfer’s IECQ-CECC approvals at http://www.iecq.org or at
www.syfer.com
Termination
(if specified)
Plating
(4) AEC-Q200. Automotive Electronics Council Stress Test Qualification
For Passive Components. Refer to Syfer application note reference
AN0009.
Printing
(if specified)
1.3 - Syfer reliability surface mount product
groups
Electrical test
Tandem
FlexiCap
TM
capacitors
(1)
Open Mode
FlexiCap
TM
capacitors
(2)
Standard FlexiCap
TM
capacitors
(3)
Standard MLC capacitor
(4)
High reliability
Test verification
Additional sample
Rel tests
(if specified)
Standard
reliability
Notes:
QC inspection
Additional Hi Rel
activities
(S02A & S05
100% burn-in, QC insp)
(1) “Tandem” construction capacitors, ie internally having the
equivalent of 2 series capacitors. If one of these should fail
short-circuit, there is still capacitance end to end and the chip will
still function as a capacitor, although capacitance maybe affected.
Refer to application note AN0021. Also available qualified to
AEC-Q200.
(2) “Open Mode” capacitors with FlexiCap
TM
termination also reduce
the possibility of a short circuit by utilising inset electrode margins.
Refer to application note AN0022. Also available qualified to
AEC-Q200.
(3) Multilayer capacitors with Syfer FlexiCap
TM
termination. By using
FlexiCap
TM
termination, there is a reduced possibility of the
mechanical cracking occurring.
(4) “Standard” capacitors includes MLCCs with tin finish over nickel,
but no FlexiCap
TM
.
Packaging
4
Finished goods store
Electronic computing software
A very old small software, which was often used before. It is very useful for hardware engineers. Someone should have posted it on the forum. I will post it again....
xiaomizia Power technology
What is the command in realview similar to obey command in axd?
Dear friends: I want to use RealView for development recently. I want to execute some scripts under RealView. I can use obey command to load scripts under AxD, but now I have switched to RealView. I d...
xibeifengse Embedded System
Calling the remove function to delete a file will result in all files in the folder being deleted.
I called the remove function to delete a file, but it deleted all the files in the folder. And the Flash driver I made always reports an error when reading DQ1 when reading data, thus exiting the writ...
huguan Embedded System
What basics are needed to learn programming?
Programmers have high salaries and good working environments, and are a profession that many students aspire to, making many non-computer science majors envious. Does that mean non-computer science ma...
xyd小英雄 Programming Basics
I want Vxworks OS source code
This kind of commercial code is rare, and is a treasure for learning. I want to get it. Is there anyone in this field who can provide it? I just want to learn....
yygy Real-time operating system RTOS
How to Eliminate the Output Offset Error of the MSP4301611 Internal 12-bit DAC Module
The manual says that it can be corrected by controlling the DAC12CALON bit, but in actual use, it is found that there is still an offset error, often a negative offset of about 0.01mv. 1. How can I el...
zhangxiajoa Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 199  1127  187  778  1494  4  23  16  31  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号