EEWORLDEEWORLDEEWORLD

Part Number

Search

C0805T272G3GBC7800

Description
Ceramic Capacitor, Ceramic, 25V, 2% +Tol, 2% -Tol, C0G, -/+30ppm/Cel TC, 0.0027uF, 0805,
CategoryPassive components    capacitor   
File Size147KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

C0805T272G3GBC7800 Overview

Ceramic Capacitor, Ceramic, 25V, 2% +Tol, 2% -Tol, C0G, -/+30ppm/Cel TC, 0.0027uF, 0805,

C0805T272G3GBC7800 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid711053246
package instruction, 0805
Reach Compliance Codecompliant
Country Of OriginMexico
ECCN codeEAR99
YTEOL7.9
capacitance0.0027 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.78 mm
JESD-609 codee3
length2 mm
negative tolerance2%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Plastic, 7 Inch
positive tolerance2%
Rated (DC) voltage (URdc)25 V
seriesC(SIZE)-COTS
size code0805
Temperature characteristic codeC0G
Temperature Coefficient30ppm/Cel ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
width1.2 mm
Product Bulletin
Ceramic Commercial-Off-The-Shelf Surface Mount Capacitors (COTS)
KEMET is a qualified supplier of various military and high reliability specifications. The COTS program is an extension
of KEMET's knowledge of high reliability test regimes and requirements. KEMET has for years supplied product that has
been "up-screened" by working with customer drawings and imposing the design and test requirements specified. The COTS
program will offer the same high quality and reliability components "up-screened" to the ordered test level at a lower cost to
the customer. It eliminates the need for customer specific drawings used to achieve the reliability level required for customer
applications. The tests and inspections imposed by the COTS program have been selected to provide the accelerated con-
ditioning and 100% screening to eliminate infant mortal failures from the population.
All COTS testing includes Voltage Conditioning and post electrical testing per MIL-PRF-55681, paragraph 4.8.3.1, Standard
voltage conditioning. For enhanced reliability, KEMET also provides the following test options and conformance certification.
Test Level “A”
Test Level “B”
Test Level “C”
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
PDA 8%
C of C
PDA 8%
DPA
C of C
PDA 8%
DPA
85/85
C of C
• All COTS testing includes
Voltage Conditioning and post
electrical testing per MIL-PRF-
55681
• DPA per EIA-469
• Humidity, steady state, low
voltage (85/85) per MIL-STD
202, Method 103, condition A
• Certificate of Compliance
KEMET COTS MLCC surface mount capacitors are available in standard EIA case sizes from 0402 to 2225 and
standard capacitance values in X7R and C0G dielectrics. Voltage ratings range from 6.3V to 200V. To order the
COTS part number use a T in the 6th digit of the part number in conjunction with the desired test level A, B, or C
in the 13th digit. A Tin/Lead termination option is also available with COTS by using a L in the 14th digit of the
part number. For additional dielectrics and voltage ratings please contact the factory or local Sales personnel.
Applications
Military Products
Space Quality Products
High Reliability Electronics
F-9038B 01/06
3 keys to control the motor, 1 key to turn the motor on and off, 2 keys to accelerate, 3 keys to decelerate
#include__CONFIG(0X1832); // 877A, the hardware has been debugged #define keyO3 RB5 //Connect the pull-up for keyboard input #define keyO4 RB4 // #define keyI2 RB2 //For output, it forms 4 buttons wit...
eeleader-mcu MCU
How to view the port status of PORTB in Hiwave
How can I see the port status of PORTB in Hiwave, in the Memory window? What is the address of PORTB? I am using the example of mc9212dg128. Thank you! :victory:...
aude5420 NXP MCU
A small oversight can ruin EMI performance
[p=24, null, left][color=rgb(51, 51, 51)][font=微软雅黑, Tahoma,]By Robert Kollman, Senior Applications Manager, Texas Instruments[/font][/color][/p][p=24, null, left][color=rgb(51, 51, 51)][font=微软雅黑, Ta...
qwqwqw2088 Analogue and Mixed Signal
AD835 usage issues
[i=s]This post was last edited by paulhyde on 2014-9-15 03:34[/i]The day of the competition is getting closer and closer. I have been preparing for it recently and have encountered some problems. Some...
wgdit Electronics Design Contest
Help: When debugging the kernel on Marvell PXA310, after the kernel starts, the serial port does not output any startup information. Tip: The serial port cannot be registered. Attached: DEBUG debugging information
I am currently porting to Android. I patched and compiled the linux kernel provided by Marvell, generated a kernel zImage file, and downloaded it to the pxa310 platform via blob tftp. The code trackin...
makun Embedded System
About msp430 F149 12864 serial communication
The routine that my boss gave me for my development version is not correct. I searched for it on the Internet for a long time and found one that I modified and it works. I will share it with you....
宇飞天 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1042  120  1831  1355  1460  21  3  37  28  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号