options for higher reliability applications. Both Group A and Group
B testing/inspection options per MIL–PRF–49467 are available for
the SM Series.
Benefits
•
•
•
•
•
•
-55°C to +125°C operating temperature range
Large Case Sizes (≥ 1515)
Formed “L” or “J” leadframe configurations.
Group A and B screening per MIL–PRF–49467 available
Reliable and robust leadframe termination system
DC voltage ratings of 500 V, 1 KV, 2 KV, 3 KV, 4 KV, 5 KV,
7.5 KV, and 10 KV
• Capacitance offerings ranging from 10 pF up to 0.39 μF
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
Ordering Information
SM20
Style/Size
SM20
SM21
SM22
SM23
SM24
SM25
SM26
1
2
N
Dielectric
SM30
SM31
SM33
SM34
SM35
SM36
N = C0G
472
Capacitance
Code (pF)
2 Significant
Digits +
Number of
Zeros
J
Capacitance
Tolerance
J = ±5%
K = ±10%
M = ±20%
P = +100%, -0%
Z = +80%, -20%
501
Voltage
501 = 500 V
102 = 1,000 V
202 = 2,000 V
302 = 3,000 V
402 = 4,000 V
502 = 5,000 V
B
Lead
Configuration
1
A = Formed "L"
B = Formed "J"
M
Testing/
Inspection Option
2
Blank = None
M = Group A per MIL–PRF–49467
Standard lead configuration is formed "J". If the appropriate character is excluded from the ordering code, the assumed lead configuration will be formed "J".
Group B testing/inspection option per MIL–PRF–49467 is available upon request. Please contact KEMET for ordering details.
150% of rated voltage for voltage rating of ≤ 1,250 VDC
120% of rated voltage for voltage rating of > 1,250 VDC
(5 ±1 seconds and charge/discharge not exceeding 50 mA)
0.15%
1,000 megohm microfarads or 100 GΩ
(Rated voltage DC applied for 120 ±5 seconds @ 25°C for voltage rating of ≤ 500 VDC)
(500 VDC applied for 120 ±5 seconds @ 25°C for voltage rating of > 500 VDC)
Parameters/Characteristics
To obtain IR limit, divide MΩ-µF value by the capacitance and compare to GΩ limit. Select the lower of the two limits.
Capacitance and dissipation factor (DF) measured under the following conditions:
1 MHz ±100 kHz and 1.0 Vrms ±0.2 V if capacitance ≤ 100 pF
1 kHz ±50 Hz and 1.0 Vrms ±0.2 V if capacitance > 100 pF
Note: When measuring capacitance it is important to ensure the set voltage level is held constant. The HP4284 and Agilent E4980 have a feature known as
Automatic Level Control (ALC). The ALC feature should be switched to "ON."
Post Environmental Limits
High Temperature Life, Biased Humidity, Moisture Resistance
[color=#454545]1) Single-step operation is possible, but continuous operation always returns to address 0: Watchdog is not turned off, and continuous operation resets DSP back to address 0. [/color] [...
I would like to ask why the breakpoints I set do not stop when debugging wince? The same breakpoints worked before, but now they do not stop, I don't know what I changed?...
After adding the component "Include_VX_TRADITIONAL_SCHEDULER" to the component, the kernel scheduling strategy adopted by the kernel is the traditional scheduling strategy. The kernel program guide ha...
In order to prevent traffic accidents, when the intelligent detection device of the car detects danger ahead, it must send a warning message to the driver. The voice alarm clearly reminds the drive...[Details]
A ventilator is an instrument that can replace or assist a person's respiratory function. It is suitable for artificial respiration of patients with respiratory failure or even respiratory arrest. I...[Details]
This article discusses how to use an ultra-low-power RF transceiver chip from Zarlink Semiconductor for pacemakers, neurostimulators, drug pumps, and other such implantable medical devices to achiev...[Details]
1. Design Overview
1. Design Intent
The rapid development of medical imaging technology continues to promote the progress of modern medicine. CT, MRI, and PET are widely ...[Details]
Implantable Cardivoerter Defibrillators (ICDs) have been in common use for several years. ICDs apply a high voltage pulse between two electrodes connected to the heart, which detects cardiac fibrillat...[Details]
As a single-host multi-slave bus system, the number of slave devices that can be connected to a 1-Wire bus is almost unlimited. In order to avoid logical conflicts, the 1-Wire bus interfaces of all...[Details]
With the development of the automobile industry, the complexity and information density of automobile information systems are increasing. Displays are no longer just basic centralized instrument di...[Details]
The small size and low cost of home appliance control boards mean that high-cost materials will not be used in the circuit to solve the electromagnetic interference problem. The interference of hom...[Details]
To help improve DC/DC conversion efficiency at lighter loads and higher frequencies, Schottky diodes can be integrated into MOSFET chips to form a single package to reduce power dissipation in the ...[Details]
Complex circuits and 3D EM simulation tools have reached a point where complex system-level behavior can be simulated before fabrication. Performing EM simulations simultaneously with circuit simul...[Details]
Multiple Input and Multiple Output (MIMO) technology is arguably the next most important development in wireless communications since the advent of digital communications. Many new wireless commun...[Details]
There are many ways to attenuate signals. The most commonly used method is to divide the voltage using resistors. The common circuits are as follows:
Oscilloscope pre-stage attenuation c...[Details]
1. Introduction
The intelligent detector discussed in this paper is an integrated semiconductor photodetector. Compared with traditional semiconductor photosensitive devices, its most ...[Details]
Power Integrations (PI) has introduced three charger/adapter reference designs using its new LinkSwitch-II series of AC-DC switching power conversion ICs. The new LinkSwitch-II devices use high-pre...[Details]
Abstract:
An amplifier solution for ceramic speaker systems is presented.
Keywords:
audio; ceramic speaker; amplifier; Class G
Today's portable devices require smaller, thinne...[Details]