EEWORLDEEWORLDEEWORLD

Part Number

Search

2639LPC7/12100L220V3

Description
Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2639LPC7/12100L220V3 Overview

Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2639LPC7/12100L220V3 Parametric

Parameter NameAttribute value
Objectid312971623
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL8.8
Actuator colorBLUE
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features220VAC FLUORESCENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact functionON-OFF-ON
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
IoT/Smart Home Selection and Analysis
It's almost the weekend, so I plan to sort it out so that I can discuss it with my boss. The following is the sorted content. In the last part, the specific characteristics and parameters of several c...
辛昕 Embedded System
[Urgent] Has anyone used the gtm900c GPRS gateway to download data from a server?
I am currently debugging the gprs module of gtm900C. The current situation is: I can upload local data to the server (network) by using the put (upload API) AT command. The question is: what AT comman...
happysky.zheng Embedded System
After installing ADS, it won't run no matter what. The following prompt keeps popping up! Emergency!
cannot obtain license for feature:codewarrior license path:c:\program files\armv1_2\licenses\license.dat flexlm error:-5,357 In the ARM License Wizard, select license.dat using Browse....
awdx1 Embedded System
Namisoft about virtual voltmeter design and virtual digital multimeter
Namisoft 's design of virtual voltmeter and virtual digital multimeterCreation of Namisoft NS- Multimeter subVI1. Right-click the icon in the upper right corner and select "Show Connection Panel"; rig...
zhouyunying Integrated technical exchanges
Newly opened section - College Student Electronic Design Competition
[i=s]This post was last edited by paulhyde on 2014-9-15 09:51[/i] In response to the requests of all electronic engineering enthusiasts, we have opened a section for undergraduate electronic design co...
亲善大使 Electronics Design Contest
Couldn't find an AF_INET address for
[i=s]This post was last edited by ienglgge on 2018-10-27 01:35[/i] ubuntu 16.04 ros kinetic. Use ssh to connect to the lower computer. On the lower computer, run the camera signal publishing node. On ...
ienglgge Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1055  2613  1290  132  111  22  53  26  3  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号