RESISTOR, THIN FILM, 0.125 W, 0.5 %, 50 ppm, 8200 ohm, SURFACE MOUNT, 0805, CHIP, ROHS COMPLIANT
CategoryPassive components    The resistor   
File Size162KB,12 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance
Download Datasheet Parametric View All

231225558202 Overview

RESISTOR, THIN FILM, 0.125 W, 0.5 %, 50 ppm, 8200 ohm, SURFACE MOUNT, 0805, CHIP, ROHS COMPLIANT

231225558202 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerVishay
package instruction, 0805
Reach Compliance Codeunknown
ECCN codeEAR99
JESD-609 codee3
Manufacturer's serial numberMCU0805
Installation featuresSURFACE MOUNT
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
method of packingTR, CARDBOARD
Rated power dissipation(P)0.125 W
Rated temperature70 °C
resistance8200 Ω
Resistor typeFIXED RESISTOR
size code0805
surface mountYES
technologyTHIN FILM
Temperature Coefficient50 ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Terminal shapeWRAPAROUND
Tolerance0.5%
Operating Voltage150 V
Base Number Matches1
MCS 0402, MCT 0603, MCU 0805, MCA 1206 - Professional
Vishay Beyschlag
Professional Thin Film Chip Resistors
FEATURES
Approved according to EN 140401-801
Excellent overall stability: Class 0.5
Professional tolerance of value: ± 0.5 % and ± 1 %
Lead (Pb)-free solder contacts
Compliant to RoHS directive 2002/95/EC
APPLICATIONS
MCS 0402, MCT 0603, MCU 0805 and MCA 1206
Professional Thin Film Flat Chip Resistors are the perfect
choice for most fields of modern professional electronics
where reliability and stability is of major concern. Typical
applications include telecommunication, medical equipment
and high-end computer and audio/video electronics.
Automotive
Telecommunication
Medical equipment
Industrial equipment
METRIC SIZE
INCH:
METRIC:
0402
RR 1005M
0603
RR 1608M
0805
RR 2012M
1206
RR 3216M
TECHNICAL SPECIFICATIONS
DESCRIPTION
Metric size
Resistance range
Resistance tolerance
Temperature coefficient
Operation mode
Climatic category (LCT/UCT/days)
Rated dissipation,
P
70 (1)
Operating voltage,
U
max.
AC/DC
Film temperature
Max. resistance change at
P
70
for resistance range,
|ΔR/R| max., after:
1000 h
8000 h
225 000 h
Insulation voltage:
1 min;
U
ins
Continuous
Failure rate: FIT
observed
75 V
75 V
0.1 x 10
-9
/h
100 V
75 V
0.1 x 10
-9
/h
200 V
75 V
0.1 x 10
-9
/h
300 V
75 V
0.1 x 10
-9
/h
125
°C
Standard
55/125/56
0.063 W
50 V
155
°C
125
°C
Power
55/155/56
0.1 W
Standard
55/125/56
0.1 W
MCS 0402
RR 1005M
10
Ω
to 4.99 MΩ
MCT 0603
RR 1608M
1
Ω
to 10 MΩ
MCU 0805
RR 2012M
1
Ω
to 10 MΩ
MCA 1206
RR 3216M
1
Ω
to 2 MΩ
± 1 %; ± 0.5 %
± 50 ppm/K; ± 25 ppm/K
Power
55/155/56
0.125 W
75 V
155
°C
Standard
55/125/56
0.125 W
150 V
125
°C
155
°C
Power
55/155/56
0.2 W
Standard
55/125/56
0.25 W
200 V
125
°C
155
°C
Power
55/155/56
0.4 W
10
Ω
to 4.99 MΩ
0.25 %
0.5 %
1.5 %
0.5 %
1.0 %
1
Ω
to 10 MΩ
0.25 %
0.5 %
1.5 %
0.5 %
1.0 %
1
Ω
to 10 MΩ
0.25 %
0.5 %
1.5 %
0.5 %
1.0 %
1
Ω
to 10 MΩ
0.25 %
0.5 %
1.5 %
0.5 %
1.0 %
Notes
(1)
The power dissipation on the resistor generates a temperature rise against the local ambient, depending on the heat flow support of the
printed-circuit board (thermal resistance). The rated dissipation applies only if the permitted film temperature is not exceeded.
• These resistors do not feature a limited lifetime when operated within the permissible limits. However, resistance value drift increasing over
operating time may result in exceeding a limit acceptable to the specific application, thereby establishing a functional lifetime.
Document Number: 28705
Revision: 20-Nov-09
For technical questions, contact:
thinfilmchip@vishay.com
www.vishay.com
191
By acquiring CICLON, TI is entering the low-voltage FET market!
[size=12pt]Last February, TI acquired CICLON, a high-frequency, high-efficiency power management semiconductor designer based in Pennsylvania. At that time, Steve Anderson, senior vice president of TI...
soso Analogue and Mixed Signal
I have a problem with orcad. Please help!
How to prevent network aliasing on the bus?...
llliii2656 FPGA/CPLD
07.07【Weekly Discussion】Evaluation of Engineer Title
Facing graduation, there are many things to deal with and they are annoying. I don’t know what to do with many things. What are the uses of the "Employment Agreement" and "Reporting Certificate" (Disp...
longxtianya Integrated technical exchanges
[ADI Engineer’s Insights, What Do You Think] High Dynamic Range ADCs – Successive Approximation or Σ-Δ?
[i=s] This post was last edited by Yuzhong on 2014-11-29 20:30 [/i] [color=#247ab5][size=14px][b]Q: My medical imaging application requires 100 dB dynamic range. Can you help me choose an ADC architec...
雨中 ADI Reference Circuit
Can programs developed with ppc2003 run under Windows Mobile 6?
I would like to ask you masters, I developed a program using ppc2003, and now I need to write an operating environment for users. How should I write it? I have tested that it can run under Windows 5.0...
fjfzpeggy Embedded System
TIc2000 F28069M
Does anyone know more about servo motors under F28069M control?...
yl8816 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 463  1463  650  2226  1402  10  30  14  45  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号