• Glass sealed package assures high reliability and high temperature operation
• Tight tolerance and stability available
• Suitable for RoHS compliant re ow
• Low cost glass sealed crystal solution
RoHS /RoHS II Compliant
RoHS/RoHS II compliant. Pb in glass (exempt 7(c) per 2015/863/EU Annex)
Typical 8.0 x 4.5 x 1.6 mm
Moisture Sensitivity Level (MSL) –This product is Hermetically Sealed and not Moisture Sensitive -MSL = N/A: Not Applicable
APPLICATIONS:
• High density applications
• Modems, communication and test equipment
• PMCIA, Wireless applications
• Microprocessor crystals
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Minimum
8.000
8.000
Operation mode
40.001
40.001
Operating Temperature
Storage Temperature
Frequency Tolerance@ +25°C
Frequency Stability over the Operating
Temperatu ( ref. to +25°C)
re
Equivalent series resistance
-10
-40
-50
-50
-----
-----
-----
-----
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging @ 25°C±3°C
Insulation Resistance
-----
-----
-----
-----
500
Typical
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
18
10
-----
-----
Maximum
100.000
40.000
100.000
60.000
+60
+85
+50
+50
ºC
ºC
ppm
ppm
MHz
Units
Notes
Fundamental
Fundamental AT-
cut (Standard)
3
rd
OT AT -cut
(Standard)
Fundamental AT-
cut (See options)
See options
See options
See options
8.000 – 10.000MHz
(Fundamental)
10.001 – 15.999MHz
(Fundamental)
16.000 – 60.000MHz
(Fundamental)
40.000 – 100.000MHz
(3
rd
OT)
100
60
50
70
7
-----
100
±5
-----
pF
pF
µW
ppm
MΩ
Ω
-----
See options
First year
@ 100Vdc
LLC
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
ABRACON IS
REVISED: 02-13-20
ISO9001-2015
CERTIFIED
CERAMIC SMD MICROPROCESSOR CRYSTAL
ABM2
ABM 2-
Frequency in MHz
e.g. 8.000MHz
14.31818MHz
26.000MHz
RoHS /RoHS II Compliant
RoHS/RoHS II compliant. Pb in glass (exempt 7(c) per 2015/863/EU Annex)
Typical 8.0 x 4.5 x 1.6 mm
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
MHz -
-
-
-
-
Packaging
Blank: Bulk
T : 1k reel
T2 : 250pcs/reel
Mode
F: Fund AT for >40MHz
Load Capacitance (pF)
Please specify CL in pF
(8 to 33pF) or S for series
Please contact ABRACON for
other values
Custom ESR if other
than standard
R
: Specify a value in Ω
(e.g.: R4 0)
Operating Temp.
(See Table 1 for details)
E : 0°C ~ + 70°C
B : -20°C ~ +70°C
C: -30°C ~ + 70°C
N: -30°C ~ + 85°C
D: -40°C ~ +85°C
Freq. Tolerance
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
(See Table 1 for details)
U: ±10 ppm
G: ±15 ppm
X : ±20 ppm
W: ±25 ppm
Y : ±30 ppm
H: ±35 ppm
A : ±80 ppm
Q: ±100 ppm
V : ±120 ppm
P: ±150 ppm
Note: See Table 1 for the availability of Operating Temp. and Freq. Stability combination
Table 1 Available Combinations of Operating Temp. and Freq. Stability
Operating Temp.
Std: -10°C ~ +60°C
E: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
Freq. Stability
U:±10ppm
√
G:±15ppm
√
√
√
X:±20ppm
√
√
√
W:±25ppm
√
√
√
√
Y:±30ppm
√
√
√
√
√
√*
H:±35ppm
√
√
√
√
√
√*
Operating Temp.
Std: -10°C ~ +60°C
E: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
Freq. Stability
Std:±50ppm
√
√
√
√
√
√*
A:±80ppm
√
√
√
√
√
√
Q:±100ppm
√
√
√
√
√
√
V:±120ppm
√
√
√
√
√
√
P:±150ppm
√
√
√
√
√
√
Note: *: Availability depends on frequency.
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
ABRACON IS
LLC
REVISED: 02-13-20
ISO9001-2015
CERTIFIED
CERAMIC SMD MICROPROCESSOR CRYSTAL
ABM2
RoHS /RoHS II Compliant
RoHS/RoHS II compliant. Pb in glass (exempt 7(c) per 2015/863/EU Annex)
Typical 8.0 x 4.5 x 1.6 mm
OUTLINE DIMENSION:
0.062±.019
(1.6 ±0.20)
Note: Due to the availability of raw materials, the chamfer may not appear on the both pads. Be advised that this does
not affect the electrical characteristics of the crystal in any way.
Dimensions: inches (mm)
REFLOW PROFILE:
LLC
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
ABRACON IS
REVISED: 02-13-20
ISO9001-2015
CERTIFIED
CERAMIC SMD MICROPROCESSOR CRYSTAL
ABM2
RoHS /RoHS II Compliant
RoHS/RoHS II compliant. Pb in glass (exempt 7(c) per 2015/863/EU Annex)
Typical 8.0 x 4.5 x 1.6 mm
TAPE & REEL:
T: 1000pcs/reel
T2: 250pcs/reel
Dimensions: mm
ATTENTION:
Abracon LLC’s products are COTS – Commercial-O -The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependent Medical applications or any application requiring high reliability
where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment,
written consent and authorization from Abracon LLC is required. Please contact Abracon LLC for more information.
When debugging 430f5418, it sometimes keeps resetting. I use a 12m crystal oscillator. I have debugged more than 10 boards in total, and they all seem normal. But now there is a problem. And the same ...
[align=center][/align] [align=left][size=4][b]Good things never come alone! From now until November 17, the TI store's biweekly special offer is on: Selected tools are [color=#ff0000]11% off[/color] f...
I saw a friend on the forum saying that there is something weird with USB, maybe it's an ASF problem. In fact, the first reaction is the USB chipset, because many USB chipsets are quite disappointing ...
中9 Panasonic Technology Star tdx-668b Hi2023E+RDA5812+AVL1108E+MXT8211a+25L8005 chipset; no need to unplug the line. Directly available, has been tested! After downloading, you can use it directly! Ad...
[i=s]This post was last edited by ydcman on 2016-12-14 16:52[/i] Before I got the development board, I downloaded all the relevant information. The manual says that each one has an ST-LINK/V2 debuggin...
0 Introduction
With the development of society, people pay more and more attention to security work. Monitoring products have been used in various fields instead of being used only in importan...[Details]
Instrument stepper motor
The stepper motor is an open-loop control element that converts electrical pulse signals into angular displacement or linear displacement. In the case of non...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
Introduction
Nowadays, people pay more and more attention to the security alarm system, and people have higher and higher requirements for the functions and performance of the alarm. This paper prop...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
Temperature compensated quartz crystal oscillator (TCXO) is widely used as a high-precision frequency source in communication systems, radar navigation systems, precision measurement and control sy...[Details]
introduction
When it comes to the production of mobile phone lithium-ion batteries, the first thing that comes to mind is Japan's industrialized mechanical assembly line, NOKIO, MOTOLROLA's st...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
Measurement compatibility
It is very important to ensure the compatibility between the pressure sensor and its actual application. Before making a pressure sensor selection, the fo...[Details]
Power supply is often the most easily overlooked link in the circuit design process. In fact, as an excellent design, power supply design should be very important, which greatly affects the perfor...[Details]
DigRF
is
poised to replace the two main forms of data communication paths between RF and baseband semiconductor devices:
analog
signaling, and proprietary digital signaling (paralle...[Details]
The biggest advantage of Profibus is that it is guaranteed by the stable international standard EN50170 and has been proven to be universal in practical applications. It has been widely used in man...[Details]