EEWORLDEEWORLDEEWORLD

Part Number

Search

811-22-008-30-007101

Description
conn spring cont 08 pos .295 smd
CategoryThe connector   
File Size2MB,6 Pages
ManufacturerMill-Max
Websitehttps://www.mill-max.com
Environmental Compliance  
Download Datasheet Parametric View All

811-22-008-30-007101 Overview

conn spring cont 08 pos .295 smd

811-22-008-30-007101 Parametric

Parameter NameAttribute value
Datasheets
811 ,813 Series (in.)
811, 813 (metric)
Featured Produc
Spring-Loaded Connectors
Standard Package1
CategoryConnectors, Interconnects
FamilyRectangular Connectors - Spring Loaded
PackagingTube
Connector TypePis
Number of Contacts8
Pitch0.100" (2.54mm)
Number of Rows1
Row Spacing-
Mounting TypeSurface Mou
MaterialCopper Alloy
Contact FinishGold
Contact Finish Thickness20µin (0.51µm)
Other Names81122008300071008112200830007101ED8117-08
SPRING-LOADED
CONNECTORS
SERIES 811 & 813 • .100” GRID SURFACE MOUNT, LOW PROFILE •
SINGLE AND DOUBLE ROW STRIPS
• Modular contacts for use on .100” grid, available in five heights from .137” to .236”, supplied
in single and double row contact strips
• Precision-machined piston / base and gold-plated components assure a 1,000,000 cycle
life durability
Pistons have a long stroke relative to the low profile of the assembly
• Low resistance, high current contacts are rated at 2 amps continuous, 3 amps peak
• High temperature thermoplastic insulators are suitable for surface mount processes
• Both 811 & 813 series, contact styles 1 through 4, are available on 32mm wide carrier tape
and fitted with vacuum pick-up clips for automated pick and place assembly. Tape and Reel
packaging per EIA-481. See page 12 for strip lengths available and ordering information
SINGLE ROW Series 811
ORDERING INFORMATION
Single Row Series 811
811-22-0XX-30-00X101
Stroke
.042 DIA.
Specify number of contacts
01-64
Specify contact style
0-4
Stroke
B
A
.071
.110
Double Row Series 813
813-22-0XX-30-00X101
Specify number of contacts
04-72
CONTACT STYLE
0
1
2
3
4
INITIAL HEIGHT A
.137
.177
.197
.217
.236
Specify contact style
0-4
MAX. STROKE B
.039
.045
.055
.055
.055
For 811 and 813 Tape & Reel packaging, see page 12
B
A
Style 0 only
.016
.072 DIA.
DOUBLE ROW Series 813
Style 0 only
B
A
.071
.100
.042 DIA.
B
A
.110
.016
.072 DIA.
Mill-Max Mfg. Corp. • 190 Pine Hollow Road, P.O. Box 300, Oyster Bay, NY 11771 • 516-922-6000 • Fax: 516-922-9253 • www.mill-max.com
PAGE 7 | SPRING-LOADED CONNECTORS
Materials:
Contact piston & base: Machined copper alloy plated 20μ” gold over 100μ” nickel
Spring: Beryllium copper-plated 10μ” gold
Insulator: High temperature thermoplastic, rated UL94 V-0
Mechanical:
Spring force @ initial height (A): 25 grams
Spring force @ mid stroke (B/2): 60 grams
Durability: 1,000,000 cycles
Coplanarity: .005” (Single Row up to 10 pins; Double Row up to 20 pins),
For higher pin counts, contact Technical Support
Electrical:
Voltage rating: 100Vrms/150Vdc
Current rating: 2A (continous), 3A (peak) per contact
Contact resistance: 20mW
max.
RoHS - 2
Insulation resistance: 10,000MW
min.
2011/65/EU
Dielectric strength: 700Vrms min.
Capacitance: 1pF max.
Technical Specifications
Stroke
Stroke
Urgently looking for a component library for Proteus that includes AC motors
I need to use AC motor in my graduation project. When running Proteus simulation, it prompts that the model is missing. Due to time constraints, I cannot earn enough chips in a short time to download ...
dg0001 MCU
STM32 FLASH problem
I want to write an array of 156300 in the FLASH of STM32ZET6, 156K, ZET6's FLASH is 512K, but after writing the program, the program cannot run at all, just like the array is out of bounds, why? Here ...
qk333333 stm32/stm8
MSP430 FAQ
MSP430 FAQs[b][size=5][color=#a0522d][/color][/size][/b]...
qwqwqw2088 Microcontroller MCU
The "magic" hub
Can you guess what this is at a glance... If you guessed it right, you are so talented! This USB hub with 8 ports has a top hat shape, which is very beautiful. It looks like a magician's prop, which i...
xyh_521 Creative Market
The principles behind Wi-Fi revealed!
Wi-Fi and 4G/5G cellular networks are the two most commonly used access methods when we go online.These two access methods may not seem to make any difference when you are surfing the Internet, but th...
btty038 RF/Wirelessly
How to remove the no-pot detection of the induction cooker so that it can work?
I want to heat an iron pipe. I use the control board of an induction cooker. I made the coil myself by wrapping the wire around the iron pipe. The inductance of the coil is the same as that of the ind...
xingmiao Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2012  2053  1849  2094  542  41  42  38  43  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号