EEWORLDEEWORLDEEWORLD

Part Number

Search

RHS001.0UD621C207411Z18

Description
Absolute Magnetostrictive Sensor
CategoryThe sensor   
File Size2MB,14 Pages
ManufacturerMTS Sensors
Websitehttps://www.mtssensors.com
Download Datasheet Parametric View All

RHS001.0UD621C207411Z18 Overview

Absolute Magnetostrictive Sensor

RHS001.0UD621C207411Z18 Parametric

Parameter NameAttribute value
Objectid1288064417
Reach Compliance Codeunknown
YTEOL8.1
Other featuresIP 67, IP 68
Linearity(%)0.01 %
Maximum operating temperature75 °C
Minimum operating temperature-40 °C
resolution5 µm
Sensor/temperature sensor typeLINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
Maximum supply voltage28.8 V
Minimum supply voltage20.4 V
Termination typeCONNECTOR
Temposonics
®
®
Magnetostrictive, Absolute, Non-contact
Linear-Position Sensors
R-Series Models RP and RH
CANbus Outputs (CANopen/CANbasic)
Data Sheet
SENS
O
RS
Document Part Number
550991 Revision D
Model RP Profile-style position sensor
FEATURES
Linear, Absolute Measurement
LEDs For Sensor Diagnostics
Superior Accuracy, Resolution down to 2 μm
Non-Contact Sensing Technology
Linearity Deviation Less Than 0.01%
Repeatability Within 0.001%
Direct CAN Output (Position + Velocity)
Model RH Rod-style position sensor
Time-based Magnetostrictive position sensing principle
Movable position magnet
Magnetic field encompasses
entire waveguide - generated
by the interrogation pulse
Interrogation
Return wire
Waveguide
Strain-Pulse detector
Bias magnet
Magnetic field from
position magnet
Interaction of magnetic
fields causes waveguide to
generate a strain pulse
BENEFITS
Rugged Industrial Sensor
Selectable Bus Termination (CANopen)
CANopen with Heartbeat Function
APPLICATIONS
Continuous Operation In Harsh Industrial Conditions
High Pressure Conditions
For Accurate, Multi-Magnet Position Measurement
(up to 20 positions per sensor)
TYPICAL INDUSTRIES
Factory Automation
Fluid Power
Plastic Injection and Blow Molding
Material Handling and Packaging
Benefits of Magnetostriction
Temposonics linear-position sensors use the time-based
magnetostrictive position sensing principle developed by MTS.
Within the sensing element, a sonic-strain pulse is induced in a
specially designed magnetostrictive waveguide by the momentary
interaction of two magnetic fields. One field comes from a moveable
permanent magnet that passes along the outside of the sensor. The
other field comes from an “interrogation” current pulse applied along
the waveguide. The resulting strain pulse travels at sonic speed along
the waveguide and is detected at the head of the sensing element.
The position of the magnet is determined with high precision and
speed by accurately measuring the elapsed time between the applica-
tion of the interrogation pulse and the arrival of the resulting strain
pulse with a high-speed counter. The elapsed time measurement is
directly proportional to the position of the permanent magnet and is
an absolute value. Therefore, the sensor's output signal corresponds
to absolute position, instead of incremental, and never requires
recalibration or re-homing after a power loss. Absolute, non-contact
sensing eliminates wear, and guarantees the best durability and
output repeatability.
All specifications are subject to change. Contact MTS for specifications and
engineering drawings that are critical to your application. Drawings contained
in this document are for reference only. Go to http://www.mtssensors.com for
the latest support documentation and related media.
What is your career plan for electronic engineering?
What is your career plan for electronic engineering?...
AngryCucumber TI Technology Forum
ADI Data - Analog Circuit Design
ADI Data - Analog Circuit Design Very useful for you whatever you are an expert or beginner!...
linda_xia Analog electronics
Prepare to connect MSP430 with Android's USB Host
The main solution is to use MSP430 to implement standard hardware, and then use the Android USB port for power supply and data transmission. Use Android as a hardware screen to implement various mobil...
nisen Microcontroller MCU
Please help explain the 430 header file
Could you please explain the functions in intrinsics.h and how they are implemented?...
zmsxhy Microcontroller MCU
Thumb software interrupt instructions
The behavior of the Thumb[font=宋体]soft interrupt instruction is exactly the same as the[/font]ARM[font=宋体]equivalent instruction. The instruction that enters the exception enters the[/font]ARM[font=宋体...
sunplusedu2012a Linux and Android
Implementation of the puppy detector in Prometheus
[i=s]This post was last edited by kejoy on 2015-5-6 12:50[/i] Many of you may have seen "Prometheus", the prequel to Alien. The most practical thing in the movie is the puppy detector used to detect u...
kejoy Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 570  1938  2780  2076  487  12  40  56  42  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号