NOTE: For non-standard capacitance values or voltages, contact your local KEMET sales representative.
50 Volt Ceramic Chips can be used in 63 volt applications.
Improved product with higher ratings and tighter capacitance tolerance product may be substituted within the same size (length, width, and thickness) at KEMET’s option.
Reels with such substitutions will be marked with the improved KEMET part numbers.
C0G CAPACITANCE RANGE – 1210, 1812, 1825, 2220, 2225
CAP.
PF
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
1200
1500
1800
2200
2700
3300
3900
4700
5600
6800
8200
10,000
12,000
15,000
18,000
22,000
27,000
33,000
CAP
CODE
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
Cap
CAP.
Cap
pF
Code
TOL.
0.5-2.4 508-249
2.7-9.1
J ,K ,M
279-919
C ,D
10.0-13.0 100-130
C ,D
15.0-24.0
J ,K ,M
150-240
27.0-51.0 270-510
C ,D G ,J ,K
,M
56.0-82.0 560-820
C
91.0-360.0
,J ,K ,M
,D G
910-361
C ,D
390.0
,J ,K ,M
G
391
430.0
431
D,F,G ,J ,K ,M
470.0
471
D,F,G ,J ,K ,M
510.0
511
560.0
,J ,K ,M
D,F,G
561
620.0
621
D,F,G ,J ,K ,M
680.0
681
750.0
751
F,G ,J ,K ,M
820.0
821
F,G ,J ,K ,M
910.0
911
F,G
102
1,000.0
,J ,K ,M
1,100.0
,J ,K ,M
F,G
112
122
1,200.0
F,G
132
1,300.0
,J ,K ,M
1,500.0
,J ,K ,M
F,G
152
1,600.0
F,G
162
,M
182
1,800.0
,J ,K
F,G
202
2,000.0
,J ,K ,M
222
2,200.0
,J ,K ,M
F,G
242
2,400.0
F,G
272
2,700.0
,J ,K ,M
3,000.0
,J ,K ,M
F,G
302
3,300.0
F,G
332
362
3,600.0
,J ,K ,M
3,900.0
,J ,K ,M
F,G
392
432
4,300.0
F,G ,J ,K ,M
472
4,700.0
F,G
512
5,100.0
,J ,K ,M
5,600.0
,J ,K ,M
F,G
562
622
6,200.0
F,G
682
6,800.0
,J ,K ,M
7,500.0
,J ,K ,M
F,G
752
8,200.0
F,G ,J
822
,M
912
9,100.0
,K
F,G
103
10,000.0
,J ,K ,M
123
12,000.0
,J ,K ,M
F,G
153
15,000.0
F,G
183
18,000.0
,J ,K ,M
22,000.0
,J ,K ,M
F,G
223
27,000.0
F,G
273
333
33,000.0
,J ,K ,M
F,G
473
47,000.0
,J ,K ,M
56,000.0
,J ,K ,M
F,G
563
683
68,000.0
F,G
823
82,000.0
,J ,K ,M
100,000.0
,J ,K ,M
F,G
104
120,000.0
F,G
124
154
150,000.0
,J ,K ,M
220,000.0
,J ,K ,M
F,G
224
274
270,000.0
F,G ,J ,K ,M
334
330,000.0
F,G
474
470,000.0
,J ,K ,M
560,000.0
,J ,K ,M
F,G
564
Cap
Tolerance 10V
D
.
FB
D
FB
K,M FB
FB
D
J,K,M FB
FB
D
FB
G,J,K,M FB
D,F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FF
FB
FB
F,G,J,K,M FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
FB
FB
F,G,J,K,M FB
F,G,J,K,M FC
FB
FB
F,G,J,K,M FC
FB
FB
F,G,J,K,M FE
FC
FB
F,G,J,K,M FF
F,G,J,K,M FG
FC
FB
F,G,J,K,M FG
FF
FB
F,G,J,K,M FB
F,G,J,K,M FB
FF
FB
F,G,J,K,M FB
FF
FF
F,G,J,K,M FB
FF
FB
F,G,J,K,M FB
F,G,J,K,M FB
FG
FB
F,G,J,K,M FB
FC
F,G,J,K,M FC
F,G,J,K,M FE
FF
F,G,J,K,M FG
FG
F,G,J,K,M FH
F,G,J,K,M FK+
F,G,J,K,M
F,G,J,K,M
F,G,J,K,M
F,G,J,K,M
C1210*
16V 25V
FB FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FB FB
FB
FB FB
FB
FF FF
FB
FB FB
FB FB
FB
FB FB
FB
FB FB
FC FC
FE
FC FC
FE
FE FE
FG
FF FF
FG FG
FC
FG FG
FF
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FC FC
FE FE
FG FG
FH FH
FK+ FK+
C1812*
C1825*
C2220
C2225
50V 100V 200V 50V 100V 200V
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB
FB FB
FB GB GB GB
FB FB
FB
FB FB
FB GB GB GB
FB FB
FB
FB FB
FB GB GB GB
FB FB
FB
FB FB
FB GB GB GB
FB FB
FB
FB FB
FB GB GB GB
FB FB
FB
FB FB
FB GB GB GB
FB FB
FC
FB FB
FE GB GB GB
FB FB
FE
FB FB
FE GB GB GB
FB FC
FE
FB FC
FG GB GB GB
FB FC
FC
FB FC
FC GB GB GB
FB FC
FF
FB
FF
FF GB GB GB
FB
FF
FF
FB
FF
FF GB GB GB
FB
FF
FF
FF FG
FG GB GB GD
FB FG
FG
FB FG
FG GB GB GH
FB FG
FB FG
GB GB GJ
FC FC
FC FC
GB GH
FE FE
FF
FF
GB GH
FG FB
GB GG
FG FB
GB GB
FB FB
GB GB
FB FB
GB GB
FB FB
GB GB
FB FB
GB GB
FB FE
GB GB
FB
FF
GB GB
FC FG
GB GB
FF FH
GB GB
FG FM+
GB GD
FH
GB GH
FM+
GD GN
GK
50V 100V 200V 50V 100V 200V 50V 100V 200V
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HB
HE
HE
HF
HB
HB
HB
HB
HB
HE
HE
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JD
JG
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JB
JD
JF
JH
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KE
KB
KB
KB
KB
KB
KB
KE
F,G ,J ,K ,M
X7R CAPACITANCE RANGE – 0402, 0603, 0805, 1206
Cap
pF
150
180
220
270
330
390
470
560
680
820
1,000
1,200
1,500
1,800
2,200
2,700
3,300
3,900
4,700
5,600
6,800
8,200
10,000
12,000
15,000
18,000
22,000
27,000
33,000
39,000
47,000
56,000
68,000
82,000
100,000
120,000
150,000
180,000
220,000
270,000
330,000
390,000
470,000
560,000
680,000
820,000
1,000,000
1,200,000
1,500,000
1,800,000
2,200,000
2,700,000
3,300,000
3,900,000
4,700,000
5,600,000
6,800,000
8,200,000
10,000,000
Cap
Code
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
125
155
185
225
275
335
395
475
565
685
825
106
Cap Tol
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
C0402
6.3V
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
10V
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
16V
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
25V
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
50V
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
BB
6.3V
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
10V
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
16V
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
C0603
25V
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
50V
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CD
100V 200V 6.3V
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DD
DD
DD
DD
DC
DC
DC
DC
DD
DD
DG
DD
DD
DD
DD
DD
DE
DG
DG
DG
10V
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DD
DD
DD
DD
DC
DC
DC
DC
DD
DD
DG
DD
DD
DD
DD
DD
DE
DG
DG
DG
16V
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DD
DD
DD
DD
DC
DC
DC
DC
DD
DD
DG
DD
DD
DD
DD
DD
DE
DG
DG
DG
C0805
25V
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DD
DD
DD
DD
DC
DC
DC
DC
DD
DD
DG
DD
DG
DG
DG
DG
50V
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DD
DD
DD
DD
DD
DD
DD
DD
DD
DE
DE
DH
DH
100V 200V 6.3V
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DD
DD
DD
DD
DD
DD
DE
DE
DE
DE
DE
DG
DG
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DE
DE
DE
DG
DG
10V
16V
C1206
25V
50V
100V 200V
CD
CC*
CC*
CC*
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EC
EC
EC
EC
EB
EB
EB
EC
ED
EE
EF
EF
ED
EF
EF
ED
EN
ED
EF
EF+
EH+
EH+
EH+
EH+
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EC
EC
EC
EC
EB
EB
EB
EC
ED
EE
EF
EF
ED
EF
EF
ED
EN
ED
EF
EF+
EH+
EH+
EH+
EH+
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EC
EC
EC
EC
EB
EB
EB
EC
ED
EE
EF
EF
ED
EF
EF
ED
EN
ED
EF
EF+
EH+
EH+
EH+
EH+
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EC
EC
EC
EC
EB
EB
EB
EC
ED
EE
EF
EG
EG
EG
EF
EH
EH+
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EC
EC
EC
EC
EC
EC
EC
EC
EC
ED
ED
ED
EH
EH
EH
EH
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EC
EC
EB
EB
EB
EB
EC
EC
EC
EC
EM
EG
EG
EG
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
EB
ED
ED
ED
ED
EM
EM
EG
*
Capacitance K or M. ontact KEMET Sales Rep for J tolerance availability. +_ Reflow Only.
NOTE: For non-standard capacitance values or voltages, contact your local KEMET sales representative.
# X7R dielectric - Extended Range Values - Cap and DF measured @ 0.5 Vrms.
Improved product with higher ratings and tighter capacitance tolerance product may be substituted within the same size (length, width, and thickness) at KEMET's option.
Reels with such substitutions will be marked with the improved KEMET part numbers.
I want to use solar power to provide a stable 6V voltage. The solar power will charge the battery during the day, and the battery will provide 6V voltage at night. What kind of battery is good?...
[color=#ff00][backcolor=rgb(238, 238, 238)][size=12px]I would like to share some tutorials on FPGA from Xinchuang Electronics. I hope it will be helpful to you. If you think it is good, please give it...
Invited by two beautiful ladies, I am here to be a guest of eew. If you have any questions about PCB, you can post them. I can usually answer them within half a day. You can search online for my chara...
[align=left][font=宋体]Nand flash is special compared to other common devices, so special devices also have special designs, so some special hardware features need to be explained: [/align][align=left]1...
Some car power products were inexplicably shut down during production, but this phenomenon did not occur after the CAN box was plugged in. I tried adding a 2K resistor between the CANH and CANL signal...
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
1. Overview
The Virtual CAN Interface (VCI) function library is an application program interface specifically provided for the use of ZLGCAN devices on PCs. The functions in the library ar...[Details]
1. Project Introduction
Shandong Dezhou Xingtai Paper Co., Ltd. is a newly built high-end paperboard production enterprise with domestic leading level established by Shandong Zhaodongfang Pape...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
Recently, news came from the certification department that the photovoltaic grid-connected inverter of Samil New Energy Co., Ltd. (hereinafter referred to as "Samil New Energy") has once again obta...[Details]
Since AC mains power may experience power outages, voltage sags and surges, continuous undervoltage and overvoltage, and frequency fluctuations during supply, these factors will affect the continuous ...[Details]
1. Overview
At present, an information revolution is in the ascendant around the world, led by microelectronics, computers and communication technologies, and centered on information technolog...[Details]
1 Introduction
With the improvement of people's quality of life, lamps are no longer just basic indoor lighting tools, but also a kind of practical art for architectural decoration. When ther...[Details]
Overview
By transmitting ultrasonic energy into the human body and receiving and processing the returning reflected signals, phased array ultrasound systems can generate images of organs and s...[Details]
There are many types and styles of digital voltmeters in design and development. Traditional digital voltmeters have their own characteristics. They are suitable for manual measurement on site. Tra...[Details]
0 Introduction
Pneumatic
artificial muscle,
also known as pneumatic muscle actuator (PMA), began to be studied in the 1950s. In recent years, it has been widely studied and applied ...[Details]
AUTOSAR is a hierarchical architecture for automotive electronic embedded software jointly launched by global automotive OEMs and suppliers. The hierarchical architecture consists of a microcontrol...[Details]