EEWORLDEEWORLDEEWORLD

Part Number

Search

C1206T392M5GBC7025

Description
Ceramic Capacitor, Ceramic, 50V, 20% +Tol, 20% -Tol, C0G, -/+30ppm/Cel TC, 0.0039uF, 1206,
CategoryPassive components    capacitor   
File Size147KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

C1206T392M5GBC7025 Overview

Ceramic Capacitor, Ceramic, 50V, 20% +Tol, 20% -Tol, C0G, -/+30ppm/Cel TC, 0.0039uF, 1206,

C1206T392M5GBC7025 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid711376684
package instruction, 1206
Reach Compliance Codecompliant
Country Of OriginMexico
ECCN codeEAR99
YTEOL6.88
capacitance0.0039 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.9 mm
JESD-609 codee3
length3.2 mm
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Plastic, 7 Inch
positive tolerance20%
Rated (DC) voltage (URdc)50 V
seriesC(SIZE)-COTS
size code1206
Temperature characteristic codeC0G
Temperature Coefficient30ppm/Cel ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
width1.6 mm
Product Bulletin
Ceramic Commercial-Off-The-Shelf Surface Mount Capacitors (COTS)
KEMET is a qualified supplier of various military and high reliability specifications. The COTS program is an extension
of KEMET's knowledge of high reliability test regimes and requirements. KEMET has for years supplied product that has
been "up-screened" by working with customer drawings and imposing the design and test requirements specified. The COTS
program will offer the same high quality and reliability components "up-screened" to the ordered test level at a lower cost to
the customer. It eliminates the need for customer specific drawings used to achieve the reliability level required for customer
applications. The tests and inspections imposed by the COTS program have been selected to provide the accelerated con-
ditioning and 100% screening to eliminate infant mortal failures from the population.
All COTS testing includes Voltage Conditioning and post electrical testing per MIL-PRF-55681, paragraph 4.8.3.1, Standard
voltage conditioning. For enhanced reliability, KEMET also provides the following test options and conformance certification.
Test Level “A”
Test Level “B”
Test Level “C”
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
PDA 8%
C of C
PDA 8%
DPA
C of C
PDA 8%
DPA
85/85
C of C
• All COTS testing includes
Voltage Conditioning and post
electrical testing per MIL-PRF-
55681
• DPA per EIA-469
• Humidity, steady state, low
voltage (85/85) per MIL-STD
202, Method 103, condition A
• Certificate of Compliance
KEMET COTS MLCC surface mount capacitors are available in standard EIA case sizes from 0402 to 2225 and
standard capacitance values in X7R and C0G dielectrics. Voltage ratings range from 6.3V to 200V. To order the
COTS part number use a T in the 6th digit of the part number in conjunction with the desired test level A, B, or C
in the 13th digit. A Tin/Lead termination option is also available with COTS by using a L in the 14th digit of the
part number. For additional dielectrics and voltage ratings please contact the factory or local Sales personnel.
Applications
Military Products
Space Quality Products
High Reliability Electronics
F-9038B 01/06
A small problem
Does one ucos clock tick necessarily run all tasks once?...
sxy4517 Real-time operating system RTOS
"ADI Analog University" collection post
[size=4][color=#000080]「ADI Simulation University」This time, I collected the materials of ADI's seminar in 2012. I don't know how many people will like it. Anyway, I will post it in the forum in the f...
chen8710 ADI Reference Circuit
Problems with using C51 microcontroller to send infrared air conditioner codes
Now the waveform sent by the microcontroller is basically the same as the waveform sent by the air conditioner remote control. I have checked it with an oscilloscope, but the air conditioner has no re...
rezire199847 51mcu
The op amp has a single power supply and a virtual ground. Is this okay?
[i=s] This post was last edited by Feihong Haojie on 2016-11-29 16:45 [/i] [size=4] The op amp is powered by a single power supply, used for common-phase amplification, and connected to a resistor for...
飞鸿浩劫 Analog electronics
Why does an overload error occur in the UART receive interrupt when writing EEPROM in STM8?
Why does the UART receive interrupt overload error occur when the STM8 writes to the EEPROM? The UART_SR is set to OR.The serial port interrupt receives data normally when the EEPROM is not written....
x02004514 stm32/stm8
【TI Technical Article】: KeyStone Memory Architecture
As massive amounts of data around the world are overwhelming wireless and wired networks, operators are facing severe challenges. They need to continuously launch networks that can meet both current a...
德仪DSP新天地 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 435  2399  2134  2081  1534  9  49  43  42  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号