1 POLE(S), 0.8A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,
CategoryCircuit protection    Circuit protection   
File Size441KB,5 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

3120-F71R-P7T1-A19QG2-0.8A Overview

1 POLE(S), 0.8A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,

3120-F71R-P7T1-A19QG2-0.8A Parametric

Parameter NameAttribute value
Objectid1297375249
Reach Compliance Codecompliant
Actuator typeROCKER
body width21 mm
body height33 mm
Body length or diameter48 mm
circuit functionMANUAL ON/OFF
Circuit protection typeTHERMAL CIRCUIT BREAKER
Environmental characteristicsCORROSSION RESISTANT
Installation featuresPANEL MOUNT
Number of poles1
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
physical size48mm x 21mm x 33mm
Rated breaking capacity8 A
Rated current0.8 A
Rated voltage (AC)250 V
Rated voltage (DC)50 V
GuidelineCCC; CSA; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Thermal Overcurrent Circuit Breaker 3120-F...
Description
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the choice
of single pole, double pole with single pole protection, and double pole
with protection on both poles. Designed for snap-in panel mounting with
versions available for three different panel cut-out sizes. Illumination is
optional and there is a range of colours and markings for the rocker.
Add on modules:
Under voltage release coil (for double pole versions only).
Magnetic trip coil for short circuit protection.
Magnetic trip coil for remote relay trip.
Auxiliary contacts for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02
Safety of household and similar electrical appliances.
3120-F3...F5
Typical applications
Technical data
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, medical equipment to EN 60601.
Standard current ratings and typical internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2-pole)
Insulation resistance
Interrupting capacity I
cn
3120-F7
2
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
Current ratings
0.1...20 A
(up to 30 A to special order, single pole only)
Typical life
AC 240 V:
DC 50 V:
DC 28 V:
AC 415 V:
AC 240 V:
0.1...20 A
0.1...4 A
4.5...16 A
0.1...20 A
0.1...16 A
0.1...16 A
17...20 A
DC 50 V:
0.1...16 A
17...20 A
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A
1-pole
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, resistive
30,000 operations at 1 x I
N
, inductive
2-pole
10,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, inductive
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Illumination voltage/power consumption
operating voltage
12 V DC
24 V DC
115 V AC
230 V AC
power consumption
Y+R
2 mA
2 mA
0.9 mA
0.9 mA
G
3.5 mA
3.5 mA
2.8 mA
2.8 mA
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A 10 x I
N
2.5...20 A 250 A 2-pole, or 150 A 1-pole
Interrupting capacity (UL 1077)
I
N
1, 2-pole
1, 2-pole
Degree of protection
(IEC 60529/DIN 40050)
Vibration
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A
1000 A
Approvals
Authority
VDE (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
DC 50 V
DC 50 V
AC 250 V; DC 50 V
AC 250 V; DC 50 V
Current ratings
0.1...20 A
0.1...20 A
2-pole
0.1...10 A
1-pole
0.1...20 A
0.1...20 A
Shock
Corrosion
Humidity
Mass
UL, CSA
CCC
operating area IP40
(IP54 with water splash protection)
terminal area IP00
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 33 g (double pole)
approx. 27 g (single pole)
Issue D
www.e-t-a.de
2
- 67
Download and save image files on wince
Now I know there is a picture address on the Internet, I want to use code to download and save it, is there any way to achieve it?...
02024160 Embedded System
G2553 and NRF24L01 receiver can always detect the carrier
During the summer vacation, I want to make a small gadget with 5 transmitters and one receiver. Since I have adjusted the 24101 of 51 before, I decided to transplant it to 2553 and use the spi module ...
ZJ3024 Microcontroller MCU
Power meter based on ADE7758
Dear experts, if you have played ADE7758, please give me some advice....
wuxinxinxinxin ADI Reference Circuit
Recruiting amateur engineers
Our company is recruiting amateur engineers, who do not need to come to the company, and are familiar with STM32F10X microcontrollers and CAN communication programming. Contact number: 13874216976...
th_zhx stm32/stm8
PWM signal reading problem (please delete the post if the method has changed)
[i=s]This post was last edited by Liang Bing on 2022-11-9 11:24[/i]PWM signal reading problem (please delete the post if the method has changed)...
凉冰 MicroPython Open Source section
Why is the timer called TIMER RA in Renesas R8 microcontroller? Isn't it usually TIMER1 or TIMER2?
Why is the timer called TIMER RA in Renesas R8 microcontroller? Isn't it usually TIMER1 or TIMER2?...
一沙一世 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 470  1362  1785  2916  2001  10  28  36  59  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号