EEWORLDEEWORLDEEWORLD

Part Number

Search

C1206T393M5RAC

Description
Ceramic Capacitor, Ceramic, 50V, 20% +Tol, 20% -Tol, X7R, -/+15ppm/Cel TC, 0.039uF, 1206,
CategoryPassive components    capacitor   
File Size147KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

C1206T393M5RAC Overview

Ceramic Capacitor, Ceramic, 50V, 20% +Tol, 20% -Tol, X7R, -/+15ppm/Cel TC, 0.039uF, 1206,

C1206T393M5RAC Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid711378204
package instruction, 1206
Reach Compliance Codecompliant
Country Of OriginMexico
ECCN codeEAR99
YTEOL7.75
capacitance0.039 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.78 mm
JESD-609 codee3
length3.2 mm
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Paper, 7 Inch
positive tolerance20%
Rated (DC) voltage (URdc)50 V
seriesC(SIZE)-COTS
size code1206
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
width1.6 mm
Product Bulletin
Ceramic Commercial-Off-The-Shelf Surface Mount Capacitors (COTS)
KEMET is a qualified supplier of various military and high reliability specifications. The COTS program is an extension
of KEMET's knowledge of high reliability test regimes and requirements. KEMET has for years supplied product that has
been "up-screened" by working with customer drawings and imposing the design and test requirements specified. The COTS
program will offer the same high quality and reliability components "up-screened" to the ordered test level at a lower cost to
the customer. It eliminates the need for customer specific drawings used to achieve the reliability level required for customer
applications. The tests and inspections imposed by the COTS program have been selected to provide the accelerated con-
ditioning and 100% screening to eliminate infant mortal failures from the population.
All COTS testing includes Voltage Conditioning and post electrical testing per MIL-PRF-55681, paragraph 4.8.3.1, Standard
voltage conditioning. For enhanced reliability, KEMET also provides the following test options and conformance certification.
Test Level “A”
Test Level “B”
Test Level “C”
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
PDA 8%
C of C
PDA 8%
DPA
C of C
PDA 8%
DPA
85/85
C of C
• All COTS testing includes
Voltage Conditioning and post
electrical testing per MIL-PRF-
55681
• DPA per EIA-469
• Humidity, steady state, low
voltage (85/85) per MIL-STD
202, Method 103, condition A
• Certificate of Compliance
KEMET COTS MLCC surface mount capacitors are available in standard EIA case sizes from 0402 to 2225 and
standard capacitance values in X7R and C0G dielectrics. Voltage ratings range from 6.3V to 200V. To order the
COTS part number use a T in the 6th digit of the part number in conjunction with the desired test level A, B, or C
in the 13th digit. A Tin/Lead termination option is also available with COTS by using a L in the 14th digit of the
part number. For additional dielectrics and voltage ratings please contact the factory or local Sales personnel.
Applications
Military Products
Space Quality Products
High Reliability Electronics
F-9038B 01/06
Urgent need for automatic bus stop announcement program
[i=s]This post was last edited by paulhyde on 2014-9-15 09:15[/i] Does anyone have an assembly language program based on the AT89C51 microcontroller? Please lend it to me for reference....
zy_sh_npk Electronics Design Contest
How to use three MOS to realize the switching of small signal to control large voltage
I would like to ask you, as shown in the figure, the SRC and DRN interfaces have two voltages of different potentials, which will control the output of COM to be the SRC potential or the DRN potential...
hjyouth Analog electronics
Gates' advice to young people is very touching
1Society is full of unfairness. Don’t try to change it. You can only adapt to it first. 2. The world doesn't care about your self-esteem. People only see your achievements. Don't overemphasize self-es...
向农 Talking about work
Can WinCE5.0 use the CImage class? Does it support GDI+?
Does WinCE5.0 support GDI+? I got this error when developing: error C2039: 'Load' : is not a member of 'ATL::CImage'. The tool I used is: VS2005. MFC single document based on Smart device. When develo...
panshiowen Embedded System
How to use Fujitsu FRAM? How do people use it?
[i=s] This post was last edited by Sur on 2013-12-23 16:50 [/i] Fujitsu FRAM, no board, how did everyone do it, did they make their own board, or what, please explain...
Sur Integrated technical exchanges
The STM32F205 chip is currently not stable -- it seems to be still in the engineering sample stage
I made a 205 board and ran a small test program of the RTX operating system. I found that the MUTEX operation would cause the S machine. (The same test program ran on 105 and was very stable).Are ther...
luckyboy stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2164  961  1608  2187  84  44  20  33  45  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号