EEWORLDEEWORLDEEWORLD

Part Number

Search

M3022--10012E-070BG

Description
Pressure Sensor
CategoryThe sensor   
File Size239KB,7 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

M3022--10012E-070BG Overview

Pressure Sensor

M3022--10012E-070BG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145071962144
Reach Compliance Codeunknown
Maximum accuracy(%)1%
Body length or diameter19.812 mm
shellSTAINLESS STEEL
Number of digits14
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
Output range0-100mV
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type1/4-19 BSPT
Maximum pressure range1015 Psi
Minimum pressure range
Pressure sensing modeGAGE
Response time1000 µs
Sensor/temperature sensor typePRESSURE SENSOR,STRAIN GUAGE
Termination typeCABLE
MSP300
Pressure Transducer
SPECIFICATIONS
Analog Output or 14-Bit Digital Pressure with 11-Bit
Temperature Output
One Piece Stainless Steel Construction
Low Cost
17-4PH or 316L Stainless Steel
Customizable
The MSP300
pressure transducer from the Microfused line of TE
is suitable for measurement of liquid or gas pressure, even for
difficult media such as contaminated water, steam, and mildly
corrosive fluids.
FEATURES
One Piece Stainless Steel
Construction
Ranges up to 15kpsi
Digital Pressure and Temperature
Output or Analog mV/Amplified
Output
±1 %Span Accuracy
UL Certification (analog only)
The transducer pressure cavity is machined from a solid piece of
17-4PH or 316L stainless steel. The standard version includes a
1/4 NPT pipe thread allowing a leak-proof, all metal sealed system.
With excellent durability, there are no o-rings, welds or organics
exposed to the pressure media.
TE’s
proprietary Microfused technology, derived from demanding
aerospace applications, employs micromachined silicon
piezoresistive strain gages fused with high temperature glass to a
stainless steel diaphragm. This approach achieves media
compatibility simply and elegantly while providing an exceptionally
stable sensor without the PN junctions of conventional
micromachined sensors.
This product is geared towards industrial and commercial OEMs
for small to high volume applications. Standard configurations are
suitable for many applications. Please contact factory for your
customization needs.
APPLICATIONS
Pumps and Compressors
Hydraulic/Pneumatic Systems
Automotive Test Systems
Energy and Water Management
Medical Gas Pressure
Leak Detection
Remote Measuring Systems
General Pressure Measurements
SENSOR SOLUTIONS
///MSP300
06/2017
Page 1
Are you used to saying LM3S or lumens? This is a question of seniority.
Although LM3S6892 is already well-known, I still see some people in the forum still calling it "Lumen". This should be a name brought over from Luminary before it was acquired by TI. People who are us...
向农 Microcontroller MCU
arms3c2410 Urgent... Please take a look, I have encountered some problems as a beginner
I am writing a key driver now. I have implemented two key drivers, but my problem is that the board does not have many interrupt ports (about 4). I want to write a key driver with about 8, but I must ...
yuanyou ARM Technology
Buffer issues in WinCE6.0 kernel mode driver
Previously, in the audio driver under WinCE6.0 (in kernel mode), 32B of space was applied for and used directly without mapping or checking embedded pointers. The application writes 32B in, and the dr...
lgh707 Embedded System
Question: What is the difference between STM32 simulation and DOWNLOAD operation?
When debugging ARM STM32, do you run it in simulation to find the problem, or do you run it directly in DOWNLOAD and then check the serial port output? Is there any difference?I seem to have seen a bu...
疯狂儿 stm32/stm8
Review and Prospect of Data-Driven Control Theory and Methods
Review and Prospect of Data-Driven Control Theory and Methods...
安_然 Test/Measurement
How can I detect the dynamic insertion and removal of the SD card at the AP level? Do I need to write a small driver myself? Or can I only use a timer to continuously query its status?
How can I detect the dynamic insertion and removal of the SD card at the AP level? Do I need to write a small driver myself? Or can I only use a timer to continuously query its status?...
小破孩one Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2726  1221  758  2252  2288  55  25  16  46  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号