The Bold specifications apply to the full operating temperature range.
Note 1: Maximum positive supply voltage of 60V must be of limited duration (<100msec) and duty cycle.) The maximum continuous supply voltage is 26V.
Note 2: Full load current (I
FL
) is defined as 1.25A for the LM2941.
Note 3: Dropout voltage is defined as the input-to output differential when the output voltage drops to 99% of its nominal value with V
OUT
+ 1V applied to V
IN
.
Note 4: VIN = V
OUT (NOMINAL)
+1V. For example, use V
IN
= 4.3V for a 3.3V regulator. Employ pulse-testing procedures to minimize temperature rise.
Note 5: Ground pin current is the regulator quiescent current. The total current drawn from the source is the sum of the load current to the ground current.
Note 6: Output voltage temperature coefficient is defined as the worst case voltage changed divided by the total temperature range.
Note 7: Thermal regulation is defined as the change in the output voltage at a time T after a change in power dissipation is applied, excluding load or line regulation
effects. Specifications are for a 200mA load pulse as V
IN
= 20V (a 4W pulse) for T = 10ms.
Note 8: VREF
≤
V
OUT
≤
(V
IN
- 1), 2.3V
≤
V
IN
≤
26V, 10mA < I
L
≤
I
FL
, T
J
≤
T
JMAX
Note 9: Comparator threshold is expressed in terms of a voltage differential at the Adjust terminal below the nominal reference voltage measured 6V input. To express
these thresholds in terms of output voltage change, multiply the error amplifier gain = V
OUT
/V
REF
= (R1 + R2)/R2. For example, at a programmable output voltage of
5V, the Error output is guaranteed to go low when the output drops by 95mVx 5V/ 1.240V = 38mV. Threshold remains constant as a percent of V
OUT
as V
OUT
is varied,
with the dropout warning occurring at typically 5% below nominal, 7.7% guaranteed.
These data sheets contain descriptions of products that are in development. The specifications are based on the engineering calculations, computer simulations and/
or initial prototype evaluation.
Preliminary Information-
These data sheets contain minimum and maximum specifications that are based on the initial device characterizations. These limits are subject to change upon the
completion of the full characterization over the specified temperature and supply voltage ranges.
The application circuit examples are only to explain the representative applications of the devices and are not intended to guarantee any circuit design or permit any
industrial property right to other rights to execute. Bay Linear takes no responsibility for any problems related to any industrial property right resulting from the use of
the contents shown in the data book. Typical parameters can and do vary in different applications. Customer’s technical experts must validate all operating parameters
including “ Typical” for each customer application.
LIFE SUPPORT AND NUCLEAR POLICY
Bay Linear products are not authorized for and should not be used within life support systems which are intended for surgical implants into the body
to support or sustain life, in aircraft, space equipment, submarine, or nuclear facility applications without the specific written consent of Bay Linear
TF0 is the overflow flag of timer T0, which can be queried and cleared by the program. TF0 is also the interrupt request source and is cleared by hardware when the CPU responds to T0 interrupt.
What I...
I would like to ask you a question: I want to cut down the Linux system (the system functions are simple, only the network function needs to be retained) and make it into an ISO CD for installation. H...
TD-SCDMA (Time Division Synchronous Code Division Multiple Access) is one of the three major standards for the third generation of mobile communications. It is a communication standard with indepen...[Details]
A ventilator is an instrument that can replace or assist a person's respiratory function. It is suitable for artificial respiration of patients with respiratory failure or even respiratory arrest. I...[Details]
1 Introduction
The multifunctional monitor is a commonly used clinical medical device. It can display the patient's electrocardiogram (ECG), respiration (RESP), blood oxygen saturation (SP...[Details]
1 Overview
Drugs are like a "double-edged sword". They can treat diseases but can also cause serious adverse consequences. The dual nature of drugs depends on whether they are used rationally....[Details]
Digital signal processors have efficient numerical computing capabilities and can provide a good development environment, while programmable logic devices have highly flexible configurability. This...[Details]
Implantable Cardivoerter Defibrillators (ICDs) have been in common use for several years. ICDs apply a high voltage pulse between two electrodes connected to the heart, which detects cardiac fibrillat...[Details]
1 Overview
The BP01 pressure sensor is specially designed for monitoring blood pressure and is mainly used in portable electronic sphygmomanometers. It uses a precision thick-film ceramic chip and...[Details]
Preface
Sleep apnea is a very common sleep breathing disease. According to research, about 24% of adult men and 9% of adult women, or more than 2 million people, suffer from this disease ...[Details]
Overview
Bioelectric signals are very weak, and there is strong interference when detecting them. Therefore, there are many technical difficulties in designing high-quality bioelectric ampli...[Details]
With the development of automatic control technology, the application of precision air pressure generation and control technology is becoming more and more extensive. However, the traditional valve...[Details]
Engineers who are new to wireless design and wireless product development need to master the basics of
RF measurement
. In many cases, this process is to enable engineers who have been engag...[Details]
This article first briefly introduces the working principles of current mode and voltage mode and their respective advantages and disadvantages; then discusses the ideal voltage mode using output c...[Details]
Today's mobile phone production testing faces an increasingly complex environment, with challenges of multiple frequency bands and multiple standards, pressure on production test speed, and pres...[Details]
Multi-parameter monitor is an important device in clinical nursing. It can monitor the patient's ECG, blood pressure, blood oxygen saturation, respiratory rate, pulse rate and temperature. At present,...[Details]
Introduction With the continuous development of economy, people's demand for automobiles is increasing day by day. Correspondingly, automobile consumer groups are becoming more and more mature. It...[Details]