EEWORLDEEWORLDEEWORLD

Part Number

Search

177-740-5-100CS4K5-18SWN

Description
Cable Assembly, 24AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-740-5-100CS4K5-18SWN Overview

Cable Assembly, 24AWG,

177-740-5-100CS4K5-18SWN Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7005077076
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL8.75
Other featuresSTANDARD: MIL-DTL-83513, EMI SHIELDED
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D FEMALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.205 mm2
DIN complianceNO
IEC complianceNO
insulator materialPOLYTETRAFLUOROETHYLENE
length0.467 mm
MIL complianceYES
Number of conductors100
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.08 Ω
shieldYES
stay19X36
Wire gauge24 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
Who has used TLC5510?
Has anyone used TLC5510? What is its package? Is it in the PCB library? Or do I have to build it myself? If anyone has good information or its package, please send it to me. 3Q nbmeixiang21@163.com...
nbmeixiang21 51mcu
Highly Integrated PROFET +24V Series Application Notes
Highly Integrated PROFET +24V Series Application Notes [size=4][color=darkred][b][/b][/color][/size]...
qwqwqw2088 Analogue and Mixed Signal
Application of lightning arrester in power supply system
[size=2]1. Basic principles of lightning protection The damage caused by lightning and other strong interference to the communication system and the consequences caused by it are serious, and lightnin...
程序天使 Industrial Control Electronics
Make a high voltage driver
Everyone, how difficult is it to make a high-voltage driving power supply, amplifying the 0-5V voltage output by DA to 0-120V, with a power supply power of 500W, a wave coefficient of less than 10mv, ...
萤火 Power technology
Why are there so many people jumping off buildings recently?
People from Beijing University of Posts and Telecommunications jumped, people from Beijing University of Science and Technology jumped, and people from Foxconn jumped. Why is this happening? . . ....
凯哥 Talking about work

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 488  1894  1482  2268  1668  10  39  30  46  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号