EEWORLDEEWORLDEEWORLD

Part Number

Search

2639LHCE23001L110V/6

Description
Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2639LHCE23001L110V/6 Overview

Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2639LHCE23001L110V/6 Parametric

Parameter NameAttribute value
Objectid313111105
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL8.9
Actuator colorGREEN
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact functionON-OFF-ON
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
illuminationLAMP
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Printed circuit diagram recognition method
Printed circuit diagrams are closely related to repairs, and their importance to repairs is second only to the electrical schematic diagram of the entire machine, so printed circuit diagrams are mainl...
lhy FPGA/CPLD
Simplify application design with IoT development kits
Engineers who choose to design a wireless IoT application from scratch will quickly realize that the task is difficult. First, building an IoT network system from scratch requires knowledge of many di...
fish001 Wireless Connectivity
SDHC card initialization process, no data can be read.
My 51 development board, SPI reads and writes SD card, and there is a problem when reading the SD card sector data. No data can be read at all, that is, the data is all 0. My initialization process is...
wuxinyi MCU
Could you please tell me about the signal transmission line?
Hello everyone, please help me look at the signal transmission line in the figure below. The transmission distance is about 30m. +-12V is used to power the op amp and other chips on the circuit board ...
武帝座一 Analog electronics
Analysis of Data Transmission Methods between Digital Video Networks
From an engineering perspective, we have three methods to interconnect independent digital network video servers to exchange programs and information: 1. Use independent storage physical media such as...
wuyugwz Industrial Control Electronics
Testing and debugging of DSP systems
Testing and debugging of DSP systemFriends who have experience in this area can share more testing and debugging experiences!...
雨墨 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2929  2115  2479  2790  2920  59  43  50  57  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号