EMI Suppression Capacitors
X2 / 275 Vac
X2 capacitors with very small dimensions
Rated ac voltage 275 V, 50/60 Hz
Construction
I
I
I
I
B 81 130
Dielectric: polypropylene (MKP)
Plastic case (UL 94 V-0)
Epoxy resin sealing, flame-retardant
Impregnated
Features
I
Very small dimensions
I
Self-healing properties
Terminals
I
Parallel wire leads, tinned
I
Two standard lead lengths
Lead spacing
±
0,4
10 mm
Lead diameter Lead length
l
1
∅
d
(mm)
(mm)
0,6
0,8
6–1
6–1
—
26
±
2
available: 6 mm und 26 mm
Other lead lengths available upon request.
Marking
Manufacturer’s logo and lot number
date code,
rated capacitance (coded),
capacitance tolerance (code letter),
rated ac voltage, type number,
interference suppression sub-class (X2),
style (MKP), climatic category,
awarded marks of conformity.
Delivery mode
Bulk (untaped)
Taped (Ammo pack or reel)
For notes on taping,
refer to chapter “Taping and packing”, page 274.
Marks of conformity
Marks of
conformity
Standards
EN 132400 / IEC 384-14, 2nd edition
UL 1414 (V
R
= 250 Vac)
Approved by UL according to
CSA C22.2 No. 0; 1 (V
R
= 250 Vac)
≥
15 mm
Lead spacing = 10 mm Lead spacing
≥
15 mm
(22 nF ... 1,0
µ
F)
AAAAA C1103
XX-10n M 275V~
AAAAA C1104
XX-µ1 M 275V~
B81130 X2 MKP/SH
40/100/21/C
V
D E
B81130 X2 MKP/SH
40/100/21/C
V
D E
IEC 384-14(2)
KMK0570-T
250 V~
250 V~
KMK0571-2
Lead spacing = 27,5 mm
(1,5 and 2,2
µ
F)
AAAAA C1155
XX-1µ5 M 275V~
B81130 X2 MKP/SH
40/100/21/C
V
D E
IEC 384-14(2)
250 V~
KMK0699-I
Certificate
18643-4670-1010/A1G
E97863/97NK11940A
E97863/97NK11940A
1)
1) Not for 1,5 and 2,2
µF
231
12/00
X2
B 81 130
275 Vac
Ordering codes and packing units
Lead
spacing
±
0,4
mm
10
C
R
Maximum
dimensions
b
×
h
×
l
(mm)
4,0
×
9,0
×
13,0
4,0
×
9,0
×
13,0
5,0
×
11,0
×
13,0
5,0
×
11,0
×
13,0
6,0
×
12,0
×
13,0
6,0
×
12,0
×
13,0
5,0
×
10,5
×
18,0
5,0
×
10,5
×
18,0
5,0
×
10,5
×
18,0
6,0
×
11,0
×
18,0
6,0
×
12,0
×
18,0
7,0
×
12,5
×
18,0
8,5
×
14,5
×
18,0
9,0
×
17,5
×
18,0
Ordering code
1)
Packing units (pcs)
Ammo Reel
Untaped
pack
Lead length
6 mm
26 mm
1700
1700
1300
1300
1100
1100
1300
1300
1300
1100
1100
900
700
700
700
600
500
400
400
350
350
350
300
250
—
—
—
—
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
720
630
510
540
540
510
320
320
280
260
240
200
200
180
—
—
—
—
—
—
1000
1000
1000
1000
1000
800
500
500
500
500
450
350
300
300
200
200
200
150
150
100
100
100
10 nF
15 nF
22 nF
33 nF
33 nF
47 nF
22 nF
33 nF
47 nF
68 nF
0,10
µ
F
0,10
µ
F
0,15
µ
F
0,22
µ
F
B81130-C1103-+
***
1000
B81130-C1153-+
***
1000
B81130-C1223-+
***
830
B81130-C1333-M
***
830
B81130-A1333-+
***
680
B81130-C1473-+
***
680
B81130-B1223-+
***
1170
B81130-B1333-+
***
1170
B81130-B1473-+
***
1170
B81130-C1683-+
***
960
B81130-C1104-M
***
960
B81130-A1104-+
***
830
B81130-C1154-+
***
680
B81130-C1224-+
***
640
B81130-B1154-+
***
B81130-B1224-+
***
B81130-C1334-+
***
B81130-C1474-M
***
B81130-A1474-+
***
B81130-C1684-M
***
B81130-B1474-+
***
B81130-B1684-+
***
B81130-C1105-M
***
B81130-A1105-+
***
B81130-C1155-M
***
B81130-A1155-+
***
B81130-C1225-M
***
B81130-A1225-+
***
680
580
480
390
390
370
—
—
—
—
—
—
—
—
15
22,5
0,15
µ
F 6,0
×
15,0
×
26,5
0,22
µ
F 7,0
×
16,0
×
26,5
0,33
µ
F 8,5
×
16,5
×
26,5
0,47
µ
F 10,5
×
16,5
×
26,5
0,47
µ
F 10,5
×
18,5
×
26,5
0,68
µ
F 11,0
×
20,5
×
26,5
0,47
µ
F
0,68
µ
F
1,0
µ
F
1,0
µ
F
1,5
µ
F
1,5
µ
F
2,2
µ
F
2,2
µ
F
11,0
×
21,0
×
31,5
11,0
×
21,0
×
31,5
12,5
×
21,5
×
31,5
13,5
×
23,0
×
31,5
15,0
×
24,5
×
31,5
18,0
×
27,5
×
31,5
18,0
×
27,5
×
31,5
19,0
×
30,0
×
31,5
27,5
Capacitance tolerance:
±
20 % = M,
±
10 % = K (closer tolerances upon request)
ˆ
ˆ
1) Replace the + by the code letter for the required capacitance tolerance.
Replace the *** by the code number for the required lead length or packing.
000 = lead length 6 mm (untaped)
026 = lead length 26 mm (untaped)
289 = taped, Ammo pack
189 = taped, reel
232
12/00
B 81 130
275 Vac
Technical data
Climatic category
in accordance with IEC 60068-1
Lower category temperature
T
min
Upper category temperature
T
max
40/100/21
X2
−
40
°
C
+
100
°
C
Passive flammability category
in accordance with IEC 40 (CO) 752 C
Damp heat test
Limit values after damp
heat test
21 days/40
°
C/93 % relative humidity
Capacitance change |
∆
C/C|
Dissipation factor change
∆
tan
δ
Insulation resistance
R
is
or time constant
τ
=
C
R
⋅
R
is
Permissible
continuous ac voltage
Permissible continuous dc voltage
DC test voltage
Dissipation factor tan
δ
(in
at 20
°
C
(upper limit values)
10
−3
)
at
275 V (50/60 Hz)
560 V
2121 V, 2 s
C
R
≤
0,1
µ
F
1 kHz 1,0
100 kHz 5
0,1
µ
F
<
C
R
≤
1
µ
F
C
R
>
1
µ
F
1,0
10
1,0
13
≤
3%
≤
0,5
⋅
10
−3
(at 1 kHz)
≤
1,0
⋅
10
−3
(at 10 kHz)
≥
50 % of minimum
as-delivered values
Insulation resistance
R
is
or time constant
τ
=
C
R
⋅
R
is
at 20
°
C, rel. humidity
≤
65 %
(minimum as-delivered values)
Impedance
Z
versus frequency
f
(typical values)
C
R
≤
0,33
µ
F
100 G
Ω
C
R
>
0,33
µ
F
30 000 s
233
12/00
X2
B 81 130
275 Vac
Pulse handling capability
Maximum permissible voltage change per unit of time for non-sinusoidal voltages (pulse, sawtooth).
V
R
Max. rate of voltage rise
V
pp
/
τ
in V/
µ
s (for
V
pp
=
V
R
)
ˆ
Lead spacing
10 mm
275 Vac
290
15 mm
110
22,5 mm
50
27,5 mm
30
ˆ
ˆ
For
V
pp
<
V
R
, the permissible voltage rise rate
V
pp
/
τ
may be multiplied by the factor
V
R
/V
pp
.
Also refer to the calculation example
in chapter “General technical information”, page 302.
V
R
Pulse characteristic
k
0
in V
2
/
µ
s (for
V
pp
≤
V
R
)
ˆ
Lead spacing
10 mm
275 Vac
220 000
15 mm
80 000
22,5 mm
35 000
27,5 mm
21 000
234
12/00
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgele-
genen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsge-
sellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this bro-
chure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be con-
sidered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1