PTR90 Series - 9 mm Multi-Ganged Potentiometer w/Rotary Switch
Product Dimensions
PTR904
23.3
±
0.5
(.917
±
.020)
PTR906
30.8
±
0.5
(1.213
±
.020)
PTR908
38.3
±
0.5
(1.508
±
.020)
M7XP0.75
SW
R4 R3
R2 R1
0.8
±
0.2
(.014
±
.007)
5.0
(.197)
SW
R6 R5
R4 R3
R2 R1
6.25
(.246)
2.5
(.098)
5.0
(.197)
6.25
(.246)
2.5
(.098)
5.0
(.197)
2.5
(.098)
5.0
(.197)
2.5
(.098)
M7XP0.75
0.8
±
0.2
(.014
±
.007)
5.0
(.197)
SW
R8 R7
R6 R5
R4 R3
R2 R1
M7XP0.75
0.8
±
0.2
(.014
±
.007)
6.25
(.246)
2.5
(.098)
5.0
(.197)
2.5
(.098)
5.0
(.197)
5.0
(.197)
2.5
(.098)
RECOMMENDED PCB LAYOUT
2.5
(.098)
6.25
(.246)
3
2
1
3
2
1
5.0
(.197)
2.5
(.098)
3
2
1
3
2
1
5.0
(.197)
RECOMMENDED PCB LAYOUT
2.5
(.098)
5.0
(.197)
2.5
(.098)
6.25
(.246)
3
3
2
1
3
2
1
3
2
1
2
1
2.5
(.098)
5.0
(.197)
5.0
(.197)
RECOMMENDED PCB LAYOUT
2.5
(.098)
2.5
(.098)
3
2
1
3
2
1
5.0
(.197)
2.5
(.098)
5.0
(.197)
5.0
(.197)
2.5
(.098)
5.0
(.197)
MOUNTING
SURFACE
DIA. HOLES
14 PLCS.
1.0 +0.2/-0
(.039 +.008/-0)
5.0
SW
(.197)
5.0
SW
(.197)
R4 R3
R2 R1
MOUNTING
SURFACE
DIA. HOLES
20 PLCS.
1.0 +0.2/-0
(.039 +.008/-0)
2.5
(.098)
6.25
(.246)
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
2.5
(.098)
3
2
1
3
2
1
R6 R5
R4 R3
R2 R1
5.0
(.197)
SCHEMATIC
3
3
3
3
SCHEMATIC
3
3
3
3
3
3
SW
MOUNTING
SURFACE
R8 R7
R6 R5
R4 R3
R2 R1
5.0
(.197)
2
DIA. HOLES
26 PLCS.
1.0 +0.2/-0
(.039 +.008/-0)
2
2 2
2
2
2 2
2 2
SCHEMATIC
3 3
3
3
3
3
3
3
1
SW
R4
1
R3
1
R2
1
R1
SW
1
1
1
1
1
1
2
2 2
2 2
2 2
2
R6 R5
R4 R3
R2 R1
DIMENSIONS:
MM
(INCHES)
1 1
SW
R8 R7
1 1
R6 R5
1 1
R4 R3
1 1
R2 R1
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
PTR90 Series - 9 mm Multi-Ganged Potentiometer w/Rotary Switch
Product Dimensions
SHAFT STYLE
"K"
SHAFT STYLE
"F"
L
±
B
18 TEETH
KNURL
F
0.5
(.020)
How To Order
PTR90 1 - 2 0 20 K - B 203
Model
• PTR90 = With
Rotary Switch
No. of Sections
• 1 = 1 Section
• 2 = 2 Sections
• 3 = 3 Sections
• 4 = 4 Sections
• 5 = 5 Sections
• 6 = 6 Sections
• 8 = 8 Sections
Pin Style
• 1 = PC Pins vertical/
down facing
and ±10 %
Total Resistance
Tolerance
•2=
PC Pins vertical/
down facing
and ±20 %
Total Resistance
Tolerance
L
±
B
0.5
(.020)
1.5
(.059)
A
1.0
(.039)
6.0 +0/-0.1
(.236 +0/-.004)
DIA.
30
°
9.5
±
0.3
(.374
±
.012)
6.0
(.236)
4.8
±
0.3
(.189
±
.012)
9.5
±
0.3
(.374
±
.012)
4.5
(.177)
4.5
(.177)
6.0 +0/-0.1
(.236 +0/-.004)
DIA.
60
°
4.8
±
0.3
(.189
±
.012)
6.5
±
0.3
(.256
±
.012)
0.8
(.031)
2.0
(.079)
0.8
(.031)
6.0
(.236)
3.5
(.138)
5.0
(.197)
0.8
(.031)
2.0
(.079)
0.8
(.031)
6.5
±
0.3
(.256
±
.012)
Center Detent Option
• 0 = No Detent
• 2 = Center Detent
3.5
(.138)
5.0
(.197)
Standard Shaft Length
• 15 = 15 mm
• 20 = 20 mm
• 25 = 25 mm
Shaft Styles
• K = Knurled Type Shaft (Metal)
18 Toothed Serration Type
• F = Flatted Metal Shaft
Resistance Taper (See Taper Charts)
Taper Series followed by Curve Number
Resistance Code (See Table)
Other shaft styles available.
SHAFT SHOWN IN CCW POSITION
SHAFT SHOWN IN CCW POSITION
L
B
A
15
(.591)
5
(.197)
6
(.236)
20
(.787)
7
(.276)
10
(.394)
25
(.984)
10
(.394)
12
(.472)
L
B
F
15
(.591)
5
(.197)
7
(.276)
20
(.787)
7
(.276)
12
(.472)
25
(.984)
10
(.394)
12
(.472)
DIMENSIONS:
MM
(INCHES)
Tapers
A Series Tapers
100
90
80
Terminal 1-2 Output Voltage
X 100 (%)
Terminal 1-3 Input Voltage
70
60
50
40
30
20
10
A6
A5
):
:
0A
A)
(3
(25
A4
A ) :
A3
(20
A):
(15
A
A):
(10
A): A1
(05
B Series Tapers
100
B1
C Series Tapers
100
): B
5
): B
(2B
3
): B
2
(B
):
(1B
B
):
90
80
Terminal 1-2 Output Voltage
X 100 (%)
Terminal 1-3 Input Voltage
70
60
50
40
30
20
10
90
80
Terminal 1-2 Output Voltage
X 100 (%)
Terminal 1-3 Input Voltage
70
60
50
40
30
20
10
(3
(25 0C):
C
C
(20 ): C 6
5
(15 C):
C) C4
:
(1 C3
(05 0C):
C
C)
:C
1
(5B
0
10
20
30
40
50
60
70
80
90
100
(4B
): B
4
(3B
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Rotational Travel (%)
Rotational Travel (%)
Rotational Travel (%)
REV. 01/14
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
There is a traditional spotlight, the small bulb seems to have tungsten filament inside;
The front stage is equipped with an electronic rectifier, high frequency, input 220, output 40KHZ, voltage
The ...
I am studying electromechanical engineering. I want a graduation project on serial communication design and analysis between PCs. I wonder if there is one. If there is, please help me. Thank you for y...
How much current does your system consume when it is working normally? Please briefly describe your hardware configuration and how to reduce power consumption~! How much current does it consume in idl...
When sending data, if the modem has just been powered on, the first transmission is always unsuccessful, but the second transmission is successful. I would like to know the reason and solution. Thank ...
At present, the development of wireless power supply technology for electric vehicles (EVs) is becoming more and more active. In 2012, Volvo of Sweden established Volvo Technology Japan in Tokyo as...[Details]
In
circuit design,
current
measurement
is widely used, and the main fields are divided into three categories: in measurement,
the electric meter
is used to measure the curre...[Details]
Automotive applications are particularly sensitive to EMI events, which are unavoidable in a noisy electrical environment consisting of a central battery, bundled wiring harnesses, various inductiv...[Details]
In order to highlight the concept of "energy saving and environmental protection" of intelligent buildings, solar street lights are designed for intelligent communities. The inclination and capacit...[Details]
Power management solutions for today's portable application processors are becoming increasingly integrated. Total power consumption, standby and sleep current consumption affect battery size, bill...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
Although it is relatively easy to check the stability of a simple amplifier at lower frequencies, it may be much more difficult to evaluate the stability of a more complex circuit. This artic...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
To understand how and why OLED power supply affects display image quality, you must first understand OLED display technology and power supply requirements. This article will explain the latest OLED...[Details]
introduction
Incandescent bulbs can emit a variety of light, but in specific applications, only green, red, and yellow light are usually needed - such as traffic lights. If an incand...[Details]
Since AC mains power may experience power outages, voltage sags and surges, continuous undervoltage and overvoltage, and frequency fluctuations during supply, these factors will affect the continuous ...[Details]