High Reliability COTS (CWR11 Style) – T493 Series COTS Space Grade
Table 1A – Ratings & Part Number Reference
Rated
Rated
Case Code/
KEMET Part Number
Voltage Capacitance Case Size
V
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
V
µF
2.2
3.3
4.7
6.8
6.8
10.0
10.0
15.0
15.0
22.0
22.0
22.0
33.0
33.0
47.0
47.0
68.0
68.0
68.0
100.0
100.0
150
150
220
330
330
1.5
2.2
3.3
4.7
4.7
6.8
6.8
10
10
15
15
15
22
22
33
33
47
47
47
68
µF
KEMET/EIA
A/3216–18
A/3216–18
A/3216–18
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
D/7343-31
C/6032-28
D/7343-31
C/6032-28
D/7343-31
D/7343-31
D/7343-31
X/7343-43
A/3216–18
A/3216–18
A/3216–18
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
D/7343-31
C/6032-28
KEMET/EIA
(See below for
part options)
T493A225(1)004(2)(3)(4)(5)(6)
T493A335(1)004(2)(3)(4)(5)(6)
T493A475(1)004(2)(3)(4)(5)(6)
T493A685(1)004(2)(3)(4)(5)(6)
T493B685(1)004(2)(3)(4)(5)(6)
T493A106(1)004(2)(3)(4)(5)(6)
T493B106(1)004(2)(3)(4)(5)(6)
T493A156(1)004(2)(3)(4)(5)(6)
T493B156(1)004(2)(3)(4)(5)(6)
T493A226(1)004(2)(3)(4)(5)(6)
T493B226(1)004(2)(3)(4)(5)(6)
T493C226(1)004(2)(3)(4)(5)(6)
T493B336(1)004(2)(3)(4)(5)(6)
T493C336(1)004(2)(3)(4)(5)(6)
T493B476(1)004(2)(3)(4)(5)(6)
T493C476(1)004(2)(3)(4)(5)(6)
T493B686(1)004(2)(3)(4)(5)(6)
T493C686(1)004(2)(3)(4)(5)(6)
T493D686(1)004(2)(3)(4)(5)(6)
T493C107(1)004(2)(3)(4)(5)(6)
T493D107(1)004(2)(3)(4)(5)(6)
T493C157(1)004(2)(3)(4)(5)(6)
T493D157(1)004(2)(3)(4)(5)(6)
T493D227(1)004(2)(3)(4)(5)(6)
T493D337(1)004(2)(3)(4)(5)(6)
T493X337(1)004(2)(3)(4)(5)(6)
T493A155(1)006(2)(3)(4)(5)(6)
T493A225(1)006(2)(3)(4)(5)(6)
T493A335(1)006(2)(3)(4)(5)(6)
T493A475(1)006(2)(3)(4)(5)(6)
T493B475(1)006(2)(3)(4)(5)(6)
T493A685(1)006(2)(3)(4)(5)(6)
T493B685(1)006(2)(3)(4)(5)(6)
T493A106(1)006(2)(3)(4)(5)(6)
T493B106(1)006(2)(3)(4)(5)(6)
T493A156(1)006(2)(3)(4)(5)(6)
T493B156(1)006(2)(3)(4)(5)(6)
T493C156(1)006(2)(3)(4)(5)(6)
T493B226(1)006(2)(3)(4)(5)(6)
T493C226(1)006(2)(3)(4)(5)(6)
T493B336(1)006(2)(3)(4)(5)(6)
T493C336(1)006(2)(3)(4)(5)(6)
T493B476(1)006(2)(3)(4)(5)(6)
T493C476(1)006(2)(3)(4)(5)(6)
T493D476(1)006(2)(3)(4)(5)(6)
T493C686(1)006(2)(3)(4)(5)(6)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Maximum/5 Min
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.9
0.9
0.9
1.3
1.3
1.9
1.9
2.7
2.7
2.7
4.0
4.0
6
6
8.8
13.2
13.2
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.9
0.9
0.9
1.4
1.4
2
2
2.9
2.9
2.9
4.1
µA @ +20ºC
Maximum/5 Min
DF
Standard
ESR
Low ESR
Moisture
Sensitivity
Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Temperature
≤ 260ºC
% @ +20ºC
Ω @ +20ºC
Ω @ +20ºC
120 Hz Maximum 100 kHz Maximum 100 kHz Maximum
6.0
8.0
6.0
6.0
8.0
4.0
6.0
8.0
3.5
6.0
6.0
3.0
6.0
5.5
2.0
6.0
6.0
2.0
6.0
3.5
1.2
6.0
4.0
1.5
6.0
3.5
1.2
6.0
4.0
1.5
6.0
3.5
0.6
6.0
1.8
0.5
6.0
3.5
0.5
6.0
1.8
0.5
6.0
3.0
0.5
6.0
1.8
0.5
6.0
3.5
2.0
6.0
1.6
0.25
6.0
0.8
0.2
8.0
1.2
0.2
8.0
0.8
0.2
8
1.2
0.3
8
0.8
0.15
8
0.9
0.7
8
0.7
0.15
8
0.5
0.2
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
6
5.5
6
3.5
4
3.5
4
3.5
1.8
3.5
1.8
3
1.8
3.5
1.6
0.8
1.2
6
6
6
3.5
3.5
2
1.2
2
1
1.5
0.7
0.6
0.6
0.5
0.6
0.3
2
0.25
0.22
0.2
% @ +20ºC
Ω @ +20ºC
Ω @ +20ºC
120 Hz Maximum 100 kHz Maximum 100 kHz Maximum
Rated
Voltage
Rated
Capacitance
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
Standard ESR
Low ESR
Moisture
Sensitivity
(1) To complete KEMET part number, insert M for ±20%, K for ±10%. Designates Capacitance tolerance.
(2) To complete KEMET part number, insert C (0.01%/1,000 hours). Designates Reliability Level.
(3) To complete KEMET part number, insert H = Solder Plated or T = 100% Tin (Sn). Designates Termination Finish.
(4) To complete KEMET part number, insert 61 = None, 62 = 10 cycles +25°C, 63 = 10 cycles -55°C +85°C after Weibull, 64 = 10 cycles -55°C +85°C before
Weibull or 65 = Both. Designates Surge current option.
(5) To complete KEMET part number, insert 1 = Standard ESR, 2 = Low ESR. Designates ESR option.
(6) To complete KEMET part number, insert A = Option 1, B = Option 2 or C = Option 3. Designates Test Option. See Space Grade Test Methods chart for more
information.
Refer to Ordering Information for additional detail.
The Shanghai R&D center of LSI, an American company, is recruiting talents in the field of communications storage with high salaries. The salary and benefits are generous. It will start allocating sha...
I have read four-fifths of Guo Tianxiang's book. I didn't have a development board before, so I learned very slowly. I just got the basics. I hope some experts can give me some tips on what kind of de...
I am a novice and have just started to learn about MCU. Now I am very interested in everything related to MCU. I also hope that friends who have become experts can share their interesting experiences ...
The component definition is as follows component jishuqi port(clkr:std_logic; outer:out std_logic; buf :inout std_logic_vector(7 downto 0)); end component; There are no other errors, except for the po...
Follow the instructions in the manual to open "ChipWatcher". I get a prompt "Please run flow to generate bit before using chip watcher...", which is red and looks like an error warning, which is diffe...
With the promotion of the construction of intelligent communities in the country, anti-theft systems have become essential equipment for intelligent communities. Especially in recent years, the urg...[Details]
Sailing is gaining more and more attention. How to use modern technology to assist training and improve competition results is particularly important. Considering the real-time data collection in t...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
When the WDP500-2A plane grating monochromator is used to test the emission wavelength of a high-power laser diode at different currents, the matching of the laser diode has the disadvantages of lo...[Details]
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
0 Introduction
With the rise and continuous improvement of the solid-state lighting industry, light-emitting diodes (LEDs) have become an alternative lighting technology and are gr...[Details]
We know that the inverter consists of two parts: the main circuit and the control circuit. Due to the nonlinearity of the main circuit (switching action), the inverter itself is a source of harmoni...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
1. Proposal of
reconfigurable
measurement and control system
The measurement and control system generally refers to a system based on
computers
to realize data acquisition a...[Details]
A stepper motor is an electromagnetic mechanical device that converts an electrical pulse signal into an angular displacement or a linear displacement. The stability and reliability of a stepper mo...[Details]
0 Introduction
There are many types of sensors, and the working principles, measurement targets and measurement environments of different types of sensors vary greatly. The corresponding detection s...[Details]
The demand for improved healthcare environments is endless, so medical imaging equipment with higher resolution is needed to better observe the human body. High resolution brings problems with sign...[Details]
Battery clamps, commonly known as battery connectors, come in two sizes depending on the thickness of the battery terminals. One is the battery clamp used on thick terminals, with a positive termin...[Details]