(Maximum Output Change in mV)............................................... 6
11/95—Revision 0: Initial Version
Rev. G | Page 2 of 16
AD586
SPECIFICATIONS
AD586J, AD586K/AD586A, AD586L/AD586B
@ T
A
= 25°C, V
IN
= 15 V, unless otherwise noted. Specifications in
boldface
are tested on all production units at final electrical test. Results
from those tests are used to calculate outgoing quality levels. All minimum and maximum specifications are guaranteed, although only
those shown in
boldface
are tested on all production units, unless otherwise specified.
Table 1.
Parameter
OUTPUT VOLTAGE
OUTPUT VOLTAGE
DRIFT
1
0°C to 70°C
−55°C to +125°C
GAIN ADJUSTMENT
LINE REGULATION
1
10.8 V < + V
IN
< 36 V
T
MIN
to T
MAX
11.4 V < +V
IN
< 36 V
T
MIN
to T
MAX
LOAD REGULATION
1
Sourcing 0 mA < I
OUT
< 10 mA
25°C
T
MIN
to T
MAX
Sinking −10 mA < I
OUT
< 0 mA
25°C
QUIESCENT CURRENT
POWER CONSUMPTION
OUTPUT NOISE
0.1 Hz to 10 Hz
Spectral Density, 100 Hz
LONG-TERM STABILITY
SHORT-CIRCUIT
CURRENT-TO-GROUND
TEMPERATURE RANGE
Specified Performance
2
Operating Performance
3
1
2
Min
4.980
AD586J
Typ
Max
5.020
AD586K/AD586A
Min
Typ
Max
4.995
5.005
AD586L/AD586B
Min
Typ
Max
4.9975
5.0025
Unit
V
25
+6
−2
+6
−2
15
+6
−2
5
ppm/°C
ppm/°C
%
%
±100
±100
±100
µV/V
µV/V
100
100
400
3
100
100
400
3
100
100
400
3
µV/mA
µV/mA
µV/mA
mA
mW
µV p-p
nV/√Hz
ppm/1000 hr
2
30
4
100
15
45
0
−40
2
30
4
100
15
2
30
4
100
15
60
70
+85
0
−40
−40
45
(K grade)
(A grade)
60
70
+85
+85
0
−40
−40
45
(L grade)
(B grade)
60
70
+85
+85
mA
°C
°C
°C
Maximum output voltage drift is guaranteed for all packages and grades. CERDIP packaged parts are also 100°C production tested.
Lower row shows specified performance for A and B grades.
3
The operating temperature range is defined as the temperature extremes at which the device will still function. Parts may deviate from their specified performance
outside their specified temperature range.
Rev. G | Page 3 of 16
AD586
AD586M, AD586S, AD586T
@ T
A
= 25°C, V
IN
= 15 V, unless otherwise noted. Specifications in
boldface
are tested on all production units at final electrical test. Results
from those tests are used to calculate outgoing quality levels. All minimum and maximum specifications are guaranteed, although only
those shown in
boldface
are tested on all production units, unless otherwise specified.
Table 2.
Parameter
OUTPUT VOLTAGE
OUTPUT VOLTAGE
DRIFT
1
0°C to 70°C
−55°C to +125°C
GAIN ADJUSTMENT
LINE REGULATION
1
10.8 V < +V
IN
< 36 V
T
MIN
to T
MAX
11.4 V < +V
IN
< 36 V
T
MIN
to T
MAX
LOAD REGULATION
1
Sourcing 0 mA < I
OUT
< 10 mA
25°C
T
MIN
to T
MAX
Sinking −10 mA < I
OUT
< 0 mA
25°C
QUIESCENT CURRENT
POWER CONSUMPTION
OUTPUT NOISE
0.1 Hz to 10 Hz
Spectral Density,
100 Hz
LONG-TERM STABILITY
SHORT-CIRCUIT
CURRENT-TO-GROUND
TEMPERATURE RANGE
Specified Performance
2
Operating Performance
3
1
2
Min
4.998
AD586M
Typ
Max
5.002
Min
4.990
AD586S
Typ
Max
5.010
Min
4.9975
AD586T
Typ
Max
5.0025
Unit
V
2
20
+6
−2
+6
−2
+6
−2
10
ppm/°C
ppm/°C
%
%
±100
±150
±150
µV/V
µV/V
100
100
400
3
150
150
400
3
150
150
400
3
µV/mA
µV/mA
µV/mA
mA
mW
µV p-p
nV/√Hz
ppm/1000 hr
2
30
4
100
15
45
0
−40
2
30
4
100
15
2
30
4
100
15
60
70
+85
−55
−55
45
60
+125
+125
−55
−55
45
60
+125
+125
mA
°C
°C
Maximum output voltage drift is guaranteed for all packages and grades. CERDIP packaged parts are also 100°C production tested.
Lower row shows specified performance for A and B grades.
3
The operating temperature range is defined as the temperature extremes at which the device will still function. Parts may deviate from their specified performance
outside their specified temperature range.
Rev. G | Page 4 of 16
AD586
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
V
IN
to Ground
Power Dissipation (25°C)
Storage Temperature
Lead Temperature (Soldering, 10 sec)
Package Thermal Resistance
θ
JC
θ
JA
Output Protection
Rating
36 V
500 mW
−65°C to +150°C
300°C
22°C/W
110°C/W
Output safe for indefinite
short to ground or V
IN
.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the
human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance