C0805T333M4RAC7800

Description
Ceramic Capacitor, Ceramic, 16V, 20% +Tol, 20% -Tol, X7R, -/+15ppm/Cel TC, 0.033uF, 0805,
CategoryPassive components    capacitor   
File Size147KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

C0805T333M4RAC7800 Overview

Ceramic Capacitor, Ceramic, 16V, 20% +Tol, 20% -Tol, X7R, -/+15ppm/Cel TC, 0.033uF, 0805,

C0805T333M4RAC7800 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid711076049
package instruction, 0805
Reach Compliance Codecompliant
Country Of OriginMexico
ECCN codeEAR99
YTEOL7.8
capacitance0.033 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.78 mm
JESD-609 codee3
length2 mm
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Plastic, 7 Inch
positive tolerance20%
Rated (DC) voltage (URdc)16 V
seriesC(SIZE)-COTS
size code0805
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
width1.2 mm
Product Bulletin
Ceramic Commercial-Off-The-Shelf Surface Mount Capacitors (COTS)
KEMET is a qualified supplier of various military and high reliability specifications. The COTS program is an extension
of KEMET's knowledge of high reliability test regimes and requirements. KEMET has for years supplied product that has
been "up-screened" by working with customer drawings and imposing the design and test requirements specified. The COTS
program will offer the same high quality and reliability components "up-screened" to the ordered test level at a lower cost to
the customer. It eliminates the need for customer specific drawings used to achieve the reliability level required for customer
applications. The tests and inspections imposed by the COTS program have been selected to provide the accelerated con-
ditioning and 100% screening to eliminate infant mortal failures from the population.
All COTS testing includes Voltage Conditioning and post electrical testing per MIL-PRF-55681, paragraph 4.8.3.1, Standard
voltage conditioning. For enhanced reliability, KEMET also provides the following test options and conformance certification.
Test Level “A”
Test Level “B”
Test Level “C”
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
PDA 8%
C of C
PDA 8%
DPA
C of C
PDA 8%
DPA
85/85
C of C
• All COTS testing includes
Voltage Conditioning and post
electrical testing per MIL-PRF-
55681
• DPA per EIA-469
• Humidity, steady state, low
voltage (85/85) per MIL-STD
202, Method 103, condition A
• Certificate of Compliance
KEMET COTS MLCC surface mount capacitors are available in standard EIA case sizes from 0402 to 2225 and
standard capacitance values in X7R and C0G dielectrics. Voltage ratings range from 6.3V to 200V. To order the
COTS part number use a T in the 6th digit of the part number in conjunction with the desired test level A, B, or C
in the 13th digit. A Tin/Lead termination option is also available with COTS by using a L in the 14th digit of the
part number. For additional dielectrics and voltage ratings please contact the factory or local Sales personnel.
Applications
Military Products
Space Quality Products
High Reliability Electronics
F-9038B 01/06
Configuration of storage space in TMS320C54x series DSP
Abstract: Please indicate the source of the reprint from DSP Exchange Network DSP Learning First Forum DSP Technology Application and Promotion Platform DSP Development Service Platform [url=http://ww...
大意了 DSP and ARM Processors
Inspired by design and copying
First of all, I want to state that this post is a repost. I think it is good, so I share it with you. Welcome to discuss. Speaking of copying boards, we actually did it more than 10 years ago. It was ...
wljmm Analog electronics
[Community Anniversary Celebration] Engineers Mutual Aid Week is in full swing! (2015.11.2 - 2015.11.8)
[align=left][color=#000][font=微软雅黑][size=3]Event period: November 2, 2015 to November 8, 2015[/size][/font][/color][/align][align=left][color=#000][font=微软雅黑][size=3] [/size][/font][/color][/align][al...
EEWORLD社区 Analogue and Mixed Signal
EEworld Forum's First Photography Competition - Discover the Beauty Around You
Beauty is everywhere, in every place, at every time...What does beauty look like in the eyes of our EEWORLD forum members? From now on, EE forum members can capture and record the beauty around them t...
eric_wang Talking
Request a copy of TI's component library and PCB library
As the title says, it is best to have a CC2541 schematic library with the suffix .olb, and the PCB library is AD9. Why not draw it yourself? I still want to ask for help. Why do I have to draw it myse...
ywlzh MCU
Challenges that Connected Vehicles bring to RF and Qorvo's solutions
With the widespread expansion of 4G/5G frequency bands and the expansion of data bandwidth using advanced carrier aggregation technology, the development trend of the Internet of Vehicles is closely f...
Jacktang RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 497  39  2689  41  2169  11  1  55  44  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号