PXE2024WD12

Description
DC-DC convrt +/-12v 20w +/-.833a
Categorysemiconductor    Power management   
File Size83KB,4 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance  
Download Datasheet Parametric View All

PXE2024WD12 Online Shopping

Suppliers Part Number Price MOQ In stock  
PXE2024WD12 - - View Buy Now

PXE2024WD12 Overview

DC-DC convrt +/-12v 20w +/-.833a

PXE2024WD12 Parametric

Parameter NameAttribute value
Datasheets
PXE Dual Instr Manual
PXE Series
Product Photos
PXE2024WD12
Other Drawings
PXE Series Side
PXE Series Bottom
Standard Package1
CategoryPower Supplies - Board Mou
FamilyDC DC Converters
PackagingBulk
TypeIsolated Module
Number of Outputs2
Voltage - Input (Min)9V
Voltage - Input (Max)36V
Voltage - Output 112V
Voltage - Output 2-12V
Voltage - Output 3-
Current - Output (Max)833mA, 833mA
Power (Watts) - Manufacture Series20W
Voltage - Isolati1.6kV (1600V)
FeaturesWith Remote On/Off
Mounting TypeThrough Hole
Package / Case8-DIP Module (7 Leads)
Size / Dimensi2.00" L x 1.60" W x 0.40" H (50.8mm x 40.6mm x 8.6mm)
Operating Temperature-40°C ~ 100°C
Efficiency81%
Power (Watts) - Max20W
Dynamic CatalogPXE Series
Other Names285-1525PXE20-24WD12
Installation Data Sheet
PXE Series (dual output) DC-DC Converters
The PXE is a DC-DC converter which provides a regulated output at power levels up to 30 watts. It accepts a wide range DC input. The
converter may be operated with or without the input and output pins grounded.
Table of Contents
General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Soldering and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
EMI Filter (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Minimum Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Outline Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Remote On-Off Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Thermal Consideration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
External Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Trim Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
General Safety Instructions
These products are designed to be PCB mounted and for use
within other equipment or enclosures. For safe installation and
operation, carefully follow the instructions below:
1. Do not install, test, or operate the products near water or
spill liquid on them.
2. Do not operate these products unless they are securely
fastened.
3. These products must be installed in a restricted access
location accessible to authorized personnel only.
4. These products must be professionally installed in
accordance with the prevailing electrical wiring regulations
and safety standards.
5. The output power taken from the unit must not exceed the
ratings stated in the catalog datasheet.
6. Ensure adequate ventilation is provided to allow air to
circulate.
7. This product has functional insulation between input and
output and therefore the DC source to this product must
be reinforced or double insulated to the AC input in
accordance with IEC/EN 60950-1 to achieve SELV output.
Soldering and Cleaning
Flow soldering : 260±10°C less than 15 seconds
Soldering iron : 370±10°C less than 5 seconds
Note: The pins of this module are coated with Tin. To assure the
solder-ability, modules should be kept in their original shipping
containers to provide adequate protection. Also, the storage
environment should be controlled to prevent oxidation of the pins.
Following wave solder, the converters should be given an
opportunity to cool to within 10°C of the cleaning solution
temperature. Cleaning while at a higher temperature may
increase the risk of vacuum absorption of the solution into the
converter between the pins and potting material during cooling.
It is recommended that during the wash process, the date code
screening is protected to avoid erasure.
Fusing
An external ceramic sand-filled fuse is needed for protection.
12V input ~ 250V, F8A, HBC
24V input ~ 250V, F5A, HBC
48V input ~ 250V, F5A, HBC
Installation Method
The unit can be mounted in any direction. Position single or
multiple units with proper spacing to allow for adequate air
ventilation. The case temperature of each unit should not exceed
the temperature range as noted in the data sheet.
Avoid placing PCB traces for the DC input and DC output directly
under the unit to limit the possibility of unwanted conducted noise.
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2686  525  2553  2721  1471  55  11  52  30  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号