EEWORLDEEWORLDEEWORLD

Part Number

Search

PXF60-24S12

Description
DC-DC converter 12v 5A sgl out
Categorysemiconductor    Power management   
File Size253KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance  
Download Datasheet Parametric View All

PXF60-24S12 Online Shopping

Suppliers Part Number Price MOQ In stock  
PXF60-24S12 - - View Buy Now

PXF60-24S12 Overview

DC-DC converter 12v 5A sgl out

PXF60-24S12 Parametric

Parameter NameAttribute value
Datasheets
PXF Series
Product Photos
PXF10-DIP-SERIES
Featured Produc
PXF Series DC-DC Converters
Standard Package1
CategoryPower Supplies - Board Mou
FamilyDC DC Converters
PackagingTube
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)18V
Voltage - Input (Max)36V
Voltage - Output 112V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (Max)5A
Power (Watts) - Manufacture Series60W
Voltage - Isolati1.6kV (1600V)
FeaturesRemote On/Off, OCP, OVP, SCP
Mounting TypeThrough Hole
Package / Case10-DIP Module (8 Leads)
Size / Dimensi2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm)
Operating Temperature-
Efficiency90%
Power (Watts) - Max60W
Dynamic CatalogPXF Series
Other Names285-1989PXF6024S12
PXF Series
Single, Dual, Triple Output 40W & 60W DC-DC Converters
Features
u
Industry Standard 2” x 2” Footprint
u
Six Sided Shielding
u
Agency Approved
u
12, 24V, and 48V Inputs (including 4:1 ranges)
u
UL, CSA, EN, CE approvals
u
Wide range input
Key Market Segments & Applications
Specifications
Model
Maximum Output Power
Voltage Accuracy (Full Load, Nom. Vin)
Voltage Adjustment
(1)
Minimum Load, each output
(2)
Line Regulation
Load Regulation (10% to 100%)
(3)
Cross Regulation (25% to 100%)
(4)
Start up time
Remote on/off (referenced to negative input)
Temperature Coefficient
Operating Temperature
Maximum Case Temperature
Storage Temperature
Thermal Shock
Relative Humidity (non condensing)
Transient Response (25% step load change)
Overvoltage Protection (Zener clamp)
Overcurrent and Short Circuit Protection
Input Surge Voltage (Maximum for 100ms)
Reflected input ripple (peak to peak)
(6)
Isolation Voltage
Isolation Resistance
Isolation Capacitance (max)
Switching Frequency (Fixed)
MTBF (BELLCORE TR-NWT-000332)
Vibration
Conducted and Radiated Emissions
Immunity
Safety Agency Approval
Size (L x W x H)
Weight
Warranty
40W or 60W
Single, Dual and Triple Main ±1%, Triple Auxiliaries ±5%
±10% (Single and Dual Output Only)
Single Output = 0%, Dual and Triple = 10% of full load rating
Single / Dual ±0.5%, Triple (main) ±1%, Triple (auxiliary) ±5%
Single ±0.5%, Dual ±1%, Triple (main) ±2%, Triple (auxiliary) ±5%
Triple (main) ±1%, Dual/Triple (auxiliary) ±5%
PXF40: 25ms typ., PXF40xxW, PXF60: 20ms max.
Positive Logic: ON: Open or 3.0-12V, OFF Short or <1.2V
<±0.02%/°C
See derating curves
PXF40: 100°C, PXF40-xxW 105°C, PXF60 110°C
PXF40: -55 to 105°C, PXF40xxW, PXF60 125°C
MIL-STD-810F
5 to 95%
250us recovery
Typical 3.3V: 3.9V, 5V: 6.2V, 12V: 15V, 15V: 18V
Typically at 150%, hiccup with self recovery
12V input: 36V, 24V input: 50V, 48V input: 100V
PXF40: 40mA, PXF40xxW, PXF60: 20mA
Input - Output, Input to Case: 1600VDC minimum
10
9
Ohms minimum
PXF40, PXF60: 1000pF, PXF40xxW: 2500pF
300kHz (typ.)
PXF40: 1,398,000; PXF40xxW: 1,105,000, PXF60: 1.093,000 hours
10 - 55Hz, 10G, 30 minutes each X, Y, Z axis
EN55022 Level A, see installation manual
EN61000-4-2, -3, -4, -5, -6
IEC60950-1, UL60950-1, EN60950-1, CE Mark (48V input only)
2 x 2 x 0.4”
2.11 oz (60g)
Two Year
(1) Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Sense and - Sense should be connected
to their corresponding outputs; + output, -output.
(2) Dual and Triple output models require a minimum load of 10% on the output to maintain specified regulation. No load operation will not damage the device.
(3) Load regulation for triple output: Main output:10-100%, with 10-100% balanced load on auxiliaries. Auxiliary outputs: 10% to 100% balanced on all outputs.
(4) Cross regulation for dual output: asymmetrical load 25% / 100% full load. Cross regulation for triple output: Main output 100% load, auxiliary 100%, other
auxiliary 25% to 100%. Auxiliary outputs: main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other
auxiliary 25% to 100%.
(5) An external filter capacitor is required for normal operation. The capacitor should be capable of handling a 1A ripple current for 48V and 24V models.
(6) Simulated Source impedence of 12uH placed in series with + input.
1-800-526-2324 • www.us.tdk-lambda.com/lp/
168
Disclaimer: us.tdk-lambda.com/lp/legal.htm

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 731  1858  637  141  1601  15  38  13  3  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号