AC DC
15 Watts
VCP Series
•
•
•
•
•
•
•
B R A N D
xppower.com
Low Cost
Output Voltages from 5 to 24 V
PCB Mounting
Open Frame & Encapsulated Versions
IT & Medical Approvals
Class II Construction
No Load Input Power <0.3 W
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
•
•
•
•
•
•
•
90-264 VAC
47-63 Hz
0.5 A max at 90 VAC
40 A max at 240 VAC, cold start at 25 °C
EN61000-3-2, class A
<0.3 W
Internal T2.0A/250 V fuse in line
General
Efficiency
Isolation
Switching Frequency
MTBF
•
•
•
•
See table
4000 VAC Input to Output
132 kHz typical
250 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature
• 0 °C to +70 °C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity
• 5-90% RH, non-condensing
Storage Temperature
• -20 °C to +80 °C
Vibration
• 10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
See table
±2% at 50% load
No minimum load required
2 s max
100 ms typical
5 ms typical at full load and 115 VAC
±0.5% max
2% max, 0-100% load
10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
See table
See table
120-280 %, auto recovery
Trip and restart (hiccup mode)
0.2 %/°C
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
•
•
•
•
•
•
•
•
•
•
•
EN55011/22, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, ±4 kV indirect contact,
±8 kV air, Perf Criteria A
EN61000-4-3, 3 V/m, Perf Criteria A
EN61000-4-4, level 2, Perf Criteria A
EN61000-4-5 installation class 3,
Perf Criteria A
EN61000-4-6, 3 V, Perf Criteria A
EN61000-4-8, 1 A/m, Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60950-1, cUL60950-1, IEC60950-1,
EN60601-1, cUL60601-1, IEC60601-1
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
Models and Ratings
Output Power
10 W
15 W
15 W
15 W
Notes
Output Voltage
(2)
5.0 V
12.0 V
15.0 V
24.0 V
Output Current
2.00 A
1.25 A
0.90 A
0.63 A
Ripple & Noise
(1)
100 mV
100 mV
150 mV
200 mV
OVP Setting
(3)
10.0 V
20.0 V
25.0 V
35.0 V
Efficiency
(5)
74%
82%
83%
84%
VCP15
Model Number
(4)
VCP15US05
VCP15US12
VCP15US15
VCP15US24
AC DC
1. Measured at DC output connector using 20 MHz bandwidth and 0.1 µF ceramic capacitor in parallel with 10 µF electrolytic capacitor placed at connector terminals.
2. Other voltages between 5.0 V and 24 V are available, consult sales for details.
3. Typical trip point.
4. For encapsulated versions, add suffix ‘-E’ to the model number e.g VCP15US24-E.
5. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input.
Mechanical Details
Open Frame Version
Encapsulated Version ( E)
0.677 (17.2)
2.72 (69.0)
1.209 (30.7)
0.484 (12.3)
3
3
0.677
(17.2)
0.67
(17.0)
2
1
0.555
(14.1)
1.65 (42.0)
2
1
1.197 (30.4)
2.55 (65.0)
1.209 (30.7)
1.197 (30.4)
1.49 (38)
0.555 (14.1)
0.15 (3.80)
0.626
(15.9)
0.465
(11.8)
TOP VIEW
TOP VIEW
4
5
4
5
0.626 (15.9)
0.465 (11.8)
0.819 (20.8)
1.205 (30.6)
0.484 (12.3)
1.27 (32.5)
0.819 (20.8)
1.205 (30.6)
0.85 (21.50)
0.06 (1.60)
ø 0.070
(ø1.80)
0.15 (3.80)
0.18
(4.50)
ø 0.04
(ø1.00)
1.24 (31.40)
1.11 (28.2)
ø 0.04
(ø1.00)
Pin
1
2
3
4
5
Designation
Live
Neutral
No connection
Output -VE
Output +VE
Notes
1. All dimensions are in inches (mm).
2. Weight: Open frame versions: 0.09 lbs (40 g) approx.
Encapsulated versions: 0.22 lbs (100 g) approx.
3. Tolerance: x.xx = ±0.04 (x.x = ±0.1); x.xxx = ±0.2 (x.xx = ±0.5)
04-Oct-11
0.67 (17.0)