Part Number

Search

VCP15US05-E

Description
AC/DC converter 5V 15w
CategoryPower/power management    The power supply circuit   
File Size127KB,2 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Parametric Compare View All

VCP15US05-E Online Shopping

Suppliers Part Number Price MOQ In stock  
VCP15US05-E - - View Buy Now

VCP15US05-E Overview

AC/DC converter 5V 15w

VCP15US05-E Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
MakerXP Power
package instruction,
Reach Compliance Codecompli
AC DC
15 Watts
VCP Series
B R A N D
xppower.com
Low Cost
Output Voltages from 5 to 24 V
PCB Mounting
Open Frame & Encapsulated Versions
IT & Medical Approvals
Class II Construction
No Load Input Power <0.3 W
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
90-264 VAC
47-63 Hz
0.5 A max at 90 VAC
40 A max at 240 VAC, cold start at 25 °C
EN61000-3-2, class A
<0.3 W
Internal T2.0A/250 V fuse in line
General
Efficiency
Isolation
Switching Frequency
MTBF
See table
4000 VAC Input to Output
132 kHz typical
250 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature
• 0 °C to +70 °C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity
• 5-90% RH, non-condensing
Storage Temperature
• -20 °C to +80 °C
Vibration
• 10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
See table
±2% at 50% load
No minimum load required
2 s max
100 ms typical
5 ms typical at full load and 115 VAC
±0.5% max
2% max, 0-100% load
10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
See table
See table
120-280 %, auto recovery
Trip and restart (hiccup mode)
0.2 %/°C
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
EN55011/22, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, ±4 kV indirect contact,
±8 kV air, Perf Criteria A
EN61000-4-3, 3 V/m, Perf Criteria A
EN61000-4-4, level 2, Perf Criteria A
EN61000-4-5 installation class 3,
Perf Criteria A
EN61000-4-6, 3 V, Perf Criteria A
EN61000-4-8, 1 A/m, Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60950-1, cUL60950-1, IEC60950-1,
EN60601-1, cUL60601-1, IEC60601-1
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient

VCP15US05-E Related Products

VCP15US05-E VCP15US15-E VCP15US12-E VCP15US05 VCP15US24-E VCP15US24 VCP15US15 VCP15US12
Description AC/DC converter 5V 15w AC/DC converter 15v 15w AC/DC converter 12v 15w AC/DC converter 5V 15w AC/DC converter 24v 15w AC/DC converter 24v 15w AC/DC converter 15v 15w AC/DC converter 12v 15w
Is it lead-free? Lead free Lead free Lead free Lead free Lead free Lead free Lead free Lead free
Reach Compliance Code compli compli compli compli compli compliant compliant compliant
Maker XP Power XP Power - XP Power XP Power - XP Power XP Power
DS18B20 reading and writing problems.
/** * 18B20 write 1 byte function * Write a byte to 1-WIRE bus */ void write_byte(unsigned char val) { unsigned char i; for (i=0; i>=1; not shifted left? Isn't it moving from the low bit to the high b...
czc568 MCU
About Circuit Board
Circuit boards are generally required to be anti-static and dust-proof during storage and transportation, but how to control them during assembly, inspection, debugging and storage? Please give me som...
wy3168 MCU
I just bought MSP430G2553 timer A and I don't know what's wrong. Please help me.
#include #include void main() { WDTCTL=WDTPW+WDTHOLD; CCTL0=CCIE; CCR0=50000; TACTL=TASSEL_2+ID1+MC_1; P1DIR=0XFF; P1OUT=0XFF; _EINT(); LPM0; } #pragma vector=TIMER0_A0_VECTOR __interrupt void Timer_A...
573547910 Microcontroller MCU
vxworks startup parameter problem
When vxworks is started, the startup parameters can be changed through the c command, but the modified parameters cannot be saved at the next startup. How can these parameters be saved? The target mac...
f56007 Real-time operating system RTOS
Protect your system from reverse current
[align=left][color=#000]Reprinted from: deyisupport[/color][/align] [align=left][color=#000]When working with electronic components, you will inevitably smell the distinct smell of a burning chip. It’...
okhxyyo Analogue and Mixed Signal
DSP introductory information (essence)
DSP introductory information (essence)...
呱呱 DSP and ARM Processors

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1554  812  1916  859  1613  32  17  39  18  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号